Summing Box/Transmitter with Process Outputs

  • Complete Strain Gage Bridge Signal Conditioner
  • High Gain, Low Drift Amplifier
  • Wide Input Range from 5 mV to 50 mV Full Scale
  • 80% Tare Offset
JBOX4800
From
Summing Box/Transmitter with Process Outputs JBOX4800 JBOX4800
loading all models
Product Overview
  • Accuratezza ± 0.1 %
  • Larghezza di banda -3 dB a 10 Hz
  • CMRR 100 dB
  • Tensione di modo comune 5 Vdc
  • Potenza elettrica Da 0 a 20 mA, da 4 a 20 mA, da 0 a 10 Vcc, da 2 a 10 Vcc
  • Classificazioni della custodia IP65, NEMA 4
  • Tensione di eccitazione Nota Intervallo di tensione di eccitazione: da 5 a 10 Vcc Uscita corrente: 120 mA max Regolazione di linea: <0,01% tipica 0,002% Rumore di uscita: <1 mVrms banda passante 120 Hz
  • Altezza 112 mm
  • Rumore in ingresso 20 mV p-p @ 100 kHz
  • Input Range Da 5 a 50 mV
  • Input Type Tensione
  • Isolation Isolamento (AC o DC, 3 vie): AC verso Ingresso o Uscita: 750 Vca DC verso Ingresso o Uscita: 300 Vcc/500 p
  • Length 318 mm
  • Linearity ± 0,01
  • Loop Resistance, Max 1000 Ω
  • Output Noise <1 mVrms, banda passante 120 Hz
  • Response Time 35 ms
  • Response Time Note 35 ms (10 al 90%)
  • Series ID JBOX4800
  • Supply Power AC: 115V (90 a 130V), 230V (180 a 260V); DC: 11 a 30V, 8 W
  • Supply Power Type AC / DC
  • Tare Adjustment -3 a 6,5 mV, 6,5 a 16 mV, 16 a 25 mV
  • Temperature Coefficient 0,0015%/°C; Totale: 0,0025%/°C
  • Weight 4.7 kg
  • Width 229 mm

Supported Applications

The Omega JBox-4800 is an AC or DC powered Summing Transmitter designed for precision weighing applications using load cells. It functions as a summing transmitter capable of processing signals from up to four load cells, providing built-in excitation and three-way isolation suitable for industrial process control add-on loops.

Operating Conditions & Performance

The JBox-4800 operates within an ambient temperature range of 10 to 35°C (50 to 95°F) with a total temperature coefficient of 0.0025%/°C typical. Accuracy is specified as less than ±0.1% at 10 V excitation between 10 and 35°C. The unit accepts an input range of 5 mV to 50 mV full scale with a linearity of ±0.01% FS.

Performance characteristics include a response time rise (10% to 90%) of 35 ms, reaching 0.1% of the final value in 100 ms. The amplifier section provides common-mode rejection of 100 dB minimum and handles input noise of 2 μV PP from 0.1 Hz to 10 Hz.

Configuration Options

The series supports configurable output signals, power inputs, and enclosure options tailored for specific installation requirements:

  • Output Signals: Available in current outputs of 0 to 20 mA or 4 to 20 mA (with a zero monitor capability of -0.3 mA), and voltage outputs of 0 to 10 Vdc or 2 to 10 Vdc.
  • Bridge Excitation: Built-in supply adjustable from 5 to 10 Vdc, delivering up to 120 mA load current with line regulation less than 0.01% typical.
  • Tare Adjustment: Three ranges available: -3 mV to +6.5 mV; +6.5 mV to +16 mV (80% F.S of a 3 mV/V cell at 10 V); and +16 mV to +25 mV.
  • Power Supply: AC input supports 115 V (90 to 130 V) or 230 V (180 to 260 V), 50/60 Hz; DC input supports 11 to 30 V.
  • Housing: Offered in a NEMA 4 Box or an optional NEMA 4X Stainless Steel Box. The enclosure rating is NEMA 4 (IP65).
  • Isolation: Three-way isolation standard: AC to Input/Output at 750 VAC; DC to Input/Output at 300 VDC with 500 pF.

The unit features four black connectors on the bottom of the enclosure for electrical connections. Optional capabilities include High/Low Setpoint-Ready User Plug-In Relays and an Opto22 I/O Module for comparator output applications.

Key Product Differences

The JBOX-4800 is a single model family designated as the 4-input summing transmitter. The primary variation lies in the enclosure material, available as either a standard NEMA 4 Box or an optional NEMA 4X Stainless Steel Box.

Output configuration varies by user selection of zero points (0 mA/2 V vs. 4 mA/10 V) and signal type (current vs. voltage). The board is wired and socketed to accept plug-in relays for high and low setpoint alarms, which are not included in the base unit but activated upon installation.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
es_ES
Save Configuration