1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
TJFT72
Sondes thermocouples à diamètre de pointe fine réduit avec fil de connexion
Reduced Fine Tip Diameter Thermocouple Probes with Lead Wire
Modèles en stock
- J, K, T, E Calibrations
- Reduced Tip = Fast Time Response
- Cold End Temperature to 200C,(392F)
- Tip Temperature to 700C, (1292F)
TJFT72
Depuis
C$
119.97
Modèles en stock
L'aperçu du produit
- Cable Length 72 in
- Color Code Standard ANSI
- Insulation PFA
- Insulation Note 1.8 m (6') PFA insulated wire with SMPW subminiature male connector
- Number of Connectors N/A
- Probe Type Fine Tip Transition Joint Probe
- Process Temperature, Min 0 °C
- Temperature Sensor Type Thermocouple
- Tip Diameter 0.02 in
- Tip Transition Joint Length 6 in
- Wire Gauge 24 AWG
- Wire Type Stranded
Fine tip transition joint thermocouple, 6" long, with 304 SS sheath, 1/16" OD. Supplied with 6 ft. PFA-insulated wire with SMPW miniature male connector. Tip has a 0.020" diameter sensing mass. <
View the Thermocouple Accuracy and Color Code charts
View the Thermocouple Accuracy and Color Code charts
PDF et manuels
Afficher les notes et les avis
Rated 3 out of
5
by
Jim L from
Careful with High Temperatures
Our probe failed after exposure to 600 C. It was a 1/16" dia. 304SS probe, K-type element. I don't know if the Inconel probe would have survived....make sure to confirm with Tech Support before purchasing.
Date published: 2016-02-22
Rated 5 out of
5
by
Prashanth from
Good sensors, fine tip length can be controlled
Good response time for the application I'm using to measure fluid temperature. Length of the fine tip can be more controlled but otherwise does a good job.
Date published: 2023-03-19
What is temperature tolerance (accuracy) for probe TJFT72-K-SS-116G-6-SMPW-M (Type K, SS 304, 6 inches)? This information was not listed on Certificate of Conformance.
These probes adhere to the Standard Limits of Error specification and would be +/- 1.1C or 0.4% of reading whichever is greater for type K.
Date published: 2019-11-06