Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

PX5200

Transmetteurs de Pression � S�curit� Intrins�que Pour Sites Dangereux, Mod�le Standards

  • Compact Size
  • NEMA 4X (IP65) Environmental Rating
  • Backlit LCD for Easy Reading
  • Display Can Be Scaled to Any Units
Transmetteurs de Pression � S�curit� Intrins�que Pour Sites Dangereux, Mod�le Standards PX5200 PX5200
loading all models
L'aperçu du produit
  • Accuracy ± 0.5 %
  • Accuracy Class > 0.25%
  • Accuracy Detail ± 0.5% FS URL (upper range limit) @23°C includes linearity, hysteresis and repeatability
  • Burst Pressure 800 psi Maximum
  • Burst Pressure Note 800 psi
  • Compensated Temperature, Max 60 °C
  • Compensated Temperature, Min -10 °C
  • Diameter 59.9 mm
  • Display Type 4 Digit LCD
  • Display Type Note 4-digit, 10mm LCD with LED Backlight, Accuracy: ± 0.5%
  • Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP65, NEMA Type 4
  • Insulation Resistance >100 MΩ @ 50 Vdc
  • Length 130 mm
  • Media Compatibility Air, Alkaline solutions, Any, Argon, Carbon dioxide, Dilute Acids, Gases, Helium, Hydraulic Oil, Hydrogen, Light Oil, Liquids, Nitrogen, Non-corrosive Dry Gasses, Oil, Oxygen, Solvents, Steam, Water, Water-based fluids
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -10 °C
  • Output Signal Current
  • Measurement Pressure Type Differential
  • Process Connection Size 1/4 in
  • Process Connection Type NPT Female
  • Proof Pressure Up to 300 psi
  • Proof Pressure Note 300 psi
  • Response Time 2 ms
  • Shock 10 g, 16 ms
  • Span Setting Adjustable Range Span: -10 to 110% FS, Zero: -10 to 110% FS
  • Stability ± 0.25%
  • Storage Temperature, Max 65 °C
  • Storage Temperature, Min -15 °C
  • Supply Voltage 12 to 32 Vdc
  • Thermal Effect on Zero error, Max ± 0.03% FS URL /°C,
  • Vibration 5g 150 Hz
  • Weight 454 g
  • Width 114 mm

The PX5200 series has been replaced by the PX3005-DIFF series . The new PX3005-DIFF series has the same features and high accuracy, but at a lower price point. Many ranges are in stock, available for immediate shipment.


The OMEGA PX5200 is a compact wet/wet differential pressure dP transmitter, ideal for flow and tank level applications where reliable, low dP measurements are required. Equipped with a solid state sensor and a 316 Stainless Steel isolating diaphragm. The PX5200 can monitor a wide variety of wet or dry media. Available in unidirectional ranges from 0 - 4 to 0 - 400 inH2O and bi-directional ranges up to ± 200 inH2O, the PX5200 operates on line (static) pressures up to 300 psi.

A rugged aluminum NEMA 4X (IP65) enclosure measures only 65 mm (2.56') in diameter and incorporates a backlit LCD display for local reading.

The output is a two-wire configurable 4 to 20 mA signal that can be adjusted to re-range the transmitter or 'tare' unwanted fluid head preloads. In addition, this instrument offers flow measurement/square root extraction, where the indicated flow rate and analog signal can be displayed. Rangeability for zero and span are from -10 to 110% FS URL (Upper Range Limit). This means a 20 inH2O transducer can have the zero set between -2 inH2O to FS 22 inH2O. Span can be set over that range also. For example zero could be set for 2 inH2O and 22 inH2O maximum so the output would be 4 mA at 2 inH2O, midpoint 12 mA would be 12 inH2O and 20 mA would be 22 inH2O.

SPECIFICATIONS
Output:
4 to 20 mAdc (2-wire)
Supply Voltage: 12 to 32 Vdc Vmin=12V+(0.022Ax loop res)
Insulation Resistance: 50 Vdc (>100 MΩ)
Rangeability/Adjustments:
Zero: -10% to 110% FS
Span: -10% to 110% FS
Accuracy: ± 0.5% FS URL (upper range limit) @23°C includes linearity, hysteresis and repeatability
Note: Accuracy and output resolution based upon FS URL (upper range limit) value.
Stability: ± 0.25% FS/year
Response Time: 100 ms (adjustable)
Output Resolution: 0.1% FS URL
Display: 4-digit, 10 mm LCD with LED backlight
Display Accuracy: ± 0.5% FS URL (upper range limit) + 1 digit
Storage Temperature: -15 to 65°C (5 to 150°F)
Operating Temperature: -10 to 60°C (14 to 140°F)
Compensated Temperature: -10 to 60°C (14 to 140°F)
Temperature Effects (Over Comp Range): ± 0.03% FS URL /°C (from 23°C reference)
Static (Line) Pressure (All Ranges): 300 psi proof; 800 psi burst
Static (Line) Pressure Effects:
≥20 inH2O, ± 8 inH2O: ± 0.03% FS/ 100 psi
8 inH2O, ± 4 inH2O: ± 0.07% FS/ 100 psi
4 inH2O: ± 0.15% FS/100 psi
Single Side (Differential) Limits:
≤8 inH2O, ± 4 inH2O: 30 psid proof; 130 psi burst
≥20 inH2O, ± 8 inH2O: 100 psid proof; 130 psi burst
Vibration: 5 g's 150 Hz
Shock: 10 g's 16 ms
Pressure Connection: 1/4; NPT female
Electrical Termination: ½ NPT female conduit fitting
Environmental Rating: NEMA 4X (IP65)
Media: Fluids and gasses compatible with 316SS, FKM, and alumina ceramic
Weight: Approx 454 g (1 lb)
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 11ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration