Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

DRA-ACT-4-Series-Sig-Cond

DIN Rail AC Voltage/Current Conditioners w/ 4-wire AC Power

  • DRA-ACT-4I Series ACCurrent Input
  • DRA-ACT-4V Series ACVoltage Input
  • ± 0.1% Accuracy
  • Isolated
DRA-ACT-4-Series-Sig-Cond
From
DIN Rail AC Voltage/Current Conditioners w/ 4-wire AC Power DRA-ACT-4-Series-Sig-Cond DRA-ACT-4-Series-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 0.1 %
  • Accuracy Detail ±0.1% of span typical (2 to 100% of span) for pure sinusoidal input
  • Additional Features 1 4-Wire AC Powered Design
  • CMRR 122 dB typical; 117 dB min
  • Electrical Output 4 to 20 mA
  • Height 119 mm
  • Input Type AC Voltage
  • Isolation 4000 Vrms/ 1min
  • Lead Compensation Error < 0.03% for full change
  • Length 73 mm
  • Loop Resistance 750 Ω @ nominal ac supply; 600 Ω @ minimum ac supply
  • Materials Polycarbonate
  • Mounting DIN Rail 35 mm Standard or Wall Mount
  • Number of Inputs 1
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min 0 °C
  • Output Ripple Better than 0.1% of span RMS
  • Output Signal Current
  • Output Value Process
  • Relative Humidity 5 to 95% RH, noncondensing
  • Response Time 220 msec
  • Series ID DRA-ACT-4-Series-Sig-Cond
  • Span Adjustment ± 25 %
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -25 °C
  • Supply Power Effects 40 to 500 Hz
  • Supply Power Note 115 Vac ± 15%, 50/60 Hz standard; 230 Vac ± 15%, 50/60 Hz optiona
  • Supply Power Type AC
  • Temperature Stability 0.02%/1°C
  • Weight 0.4 kg
  • Width 45 mm
  • Zero Setting Adjustable Range ±35% min

Supported Applications

The Omega DRA-ACT-4 series comprises isolated AC signal conditioners designed to convert measured AC current or AC voltage inputs into a proportional, linear 4 to 20 mA output. The DRA-ACT-4I models serve as ac current input transmitters, while the DRA-ACT-4V models function as ac voltage input transmitters. These units are engineered for DIN rail mount or wall mount installations in industrial environments requiring signal isolation and conditioning.

Operating Conditions & Performance

The series operates within an ambient temperature range of 32 to 158°F (0 to 70°C) with a storage temperature capability from -13 to 185°F (-25 to 85°C). Humidity tolerance is rated at 5 to 95% RH, noncondensing. Performance specifications include an accuracy of ±0.1% of span typical (2 to 100% of span) for pure sinusoidal input and a temperature stability of 0.02%/1°C. The response time is documented as 220 msec (0 to 98%).

Electrical isolation ratings vary by model family: DRA-ACT-4I series provides 2.5 KV RMS/1 min for current input and 4 KV RMS/1 min for power input, while the DRA-ACT-4V series offers 4 KV RMS/1 minute of isolation.

Measurement Ranges

  • DRA-ACT-4I (AC Current Input): 0 to 1 Aac or 0 to 5 Aac
  • DRA-ACT-4V (AC Voltage Input): 0 to 150 Vac, 0 to 250 Vac, or 0 to 400 Vac

Electrical Specifications

  • Output Signal: 4 to 20 mA
  • Frequency Range: 40-500 Hz
  • CMR (Common Mode Rejection): 122 dB typical; 117 dB min
  • Output Ripple: better than 0.1% of span RMS
  • Loop Resistance: 750 Ω @ nominal ac supply; 600 Ω @ minimum ac supply
  • Supply and Load Variation Effect: < 0.03% for full change

Configuration Options

The series supports configurable input ranges based on the specific model suffix, covering both AC current and AC voltage applications. Power supply options include a standard configuration of 115 Vac ± 15%, 50/60 Hz, with an optional 230 Vac ± 15%, 50/60 Hz available by adding the "-230" suffix to the model number at no additional charge. The housing is constructed from polycarbonate.

Available Models

  • DRA-ACT-4I-1: 0 to 1 A ac input, 4 to 20 mA output
  • DRA-ACT-4I-2: 0 to 5 A ac input, 4 to 20 mA output
  • DRA-ACT-4V-1: 0 to 150 Vac input, 4 to 20 mA output
  • DRA-ACT-4V-2: 0 to 250 Vac input, 4 to 20 mA output
  • DRA-ACT-4V-3: 0 to 400 Vac input, 4 to 20 mA output

Mechanical Dimensions & Weight

  • Dimensions (W x H x L): 1.77 in x 2.87 in x 4.69 in (45 mm x 73 mm x 119 mm)
  • Weight: 0.9 lb (0.4 kg)

Key Product Differences

The primary distinction within the series is the input type and range, separating AC current models (DRA-ACT-4I) from AC voltage models (DRA-ACT-4V). Input power consumption differs by model: DRA-ACT-4I consumes 0.26 VA at a 5 Aac input; DRA-ACT-4V consumes 0.3 VA at 120 Vac input and 1.4 VA at 230 Vac input.

Calibration is performed using front-panel Zero and Span potentiometers for fine tuning, following factory-set coarse ranging. The series includes a 1-year warranty with an optional OMEGACARE™ extended warranty program available upon request.

en-NL
en_NL
Save Configuration