OM-CP-RFPRHTEMP2000A

Wireless Pressure, Humidity and Temperature Data Loggerwith Display

Choose a Variant

Number of Measurements

C$883.71 / each

Item# OM-CP-RFPRHTEMP2000A

In Stock

Lead Time (If not in stock): 6 Days

Product Specs

<< See all Product Models
Brand
Additional Features 1 Field Upgradeable
Alarm Note User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
Band Frequency 2.405 to 2.475 GHz
Band Frequency Note ISM band 2.405 to 2.48 GHz (channels 11 through 25) @ 250 kbps data rate
Battery Size and Type Li-ion, 9V
Battery life 5 yr, typical with reading interval of 1 min
Baud Rate 250000
Calibration Digital Calibration through Software
Calibration Accuracy Temperature: ± 0.5°C for 0 to 50°C, Pressure: ± 10 mbar, Relative Humidity: ± 3% RH
Calibration Date Automated
Commodity Code 9026.20.0000
Configuration Omega Data Logging Software, Windows PC
Current Resolution Temperature: 0.01°C, Resistance: 0.001 Ω
Data Format atm, °C, dew point, °F, inHg, K, kPa, m, mbar, mg/mL, mmHg, MPa, Pa, PSI, °R, %RH, Torr
Data Interface Wireless, USB
Data Interface Note USB to mini USB, 250,000 baud for standalone operation or OM-CP-RFC1000- EXT required for wireless operation
DepthValue 4.35
Display LCD
ECCN 3A992.a
Form factor Wall Mount
GrossWeightValue 0.58
Height 0.95 in
HeightUoM IN
HeightValue 3.45
Input Type Internal
LED Functionality Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition
Length 3 in
Materials Plastic
Measurement Pressure, Max 1300 mBar
Measurement Pressure, Min 250 mBar
Measurement Type Pressure, Relative Humidity, Temperature
Memory Modes Yes
NetWeightValue 0.58
Number of Measurements 3
OkForExport true
Operating Temperature Note -20 to 60°C, 0.002 to 100 psi
Operating Temperature, Max 60 °C
Operating Temperature, Min -20 °C
RF Frequency 2.45 GHz
RF Frequency Note 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
RH Measurement Range 0 to 95% RH
RH Resolution 0.1%, 12 bit
RRS Code 1
Relative Humidity 0 to 95% RH non-condensing
Resistance Resolution 0.001 Ω
Samples,Max 10752 Samples, Interval Selectable 1 Sec to 24 hrs
Series ID OM-CP-RFPRHTEMP2000A-Series
Software Windows XP SP3/Vista/7 and 8 (32 and 64-bit)
Start Modes At set date and time, Button Push, Immediate Start, Next Interval
Supply Power Type Battery
Taxonomy Level 1 MGI
Taxonomy Level 2 DL
Taxonomy Level 3 MH
Taxonomy Level 4 PO
Temperature Measurement, Max 60 °C
Temperature Measurement, Min -20 °C
Temperature Resolution 0.01 °C
Time Accuracy ± 1 minute/month
Weight 4.9 oz
WeightUoM LB
Width 3.5 in
WidthValue 5.75
Country of Origin United States
See All Specs Show Less
Wireless Pressure, Humidity and Temperature Data Loggerwith Display OM-CP-RFPRHTEMP2000A OM-CP-RFPRHTEMP2000A
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration