Need assistance? Call us: 1-800-663-4209
Series-WWDP
Wet-to-Wet Differential Pressure Transmitter, 30 Configurable Options
Models In Stock
- Versatile device for liquid or gas supports designs requiring more precise measurements in support of application
- Field selectable port swap eliminates costly re-plumbing if unit is re-installed or replaced
- Uni-directional and bi-directional pressure selection with configurable output provides a single device that can meet broad application needs without having to specify multiple devices
- Optional LCD display provides local status to identify operational conditions
- NEMA 4 rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
Series-WWDP
From
C$
1,603.73
Models In Stock
Product Overview
- Accuracy ± 1 %
- Accuracy Detail All pressure ranges have ± 1% FS accuracy except the lowest selectable range of each unit is ± 2% FS
- Burst Pressure 10,000 psi Maximum
- Compensated Temperature, Max 54 °C
- Compensated Temperature, Min 0 °C
- Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
- Electrical Output 4 to 20 mA, 0 to 5 Vdc, 0 to 1 Vdc
- Enclosure Ratings IP56, NEMA Type 4
- Long Term Stability ± 0.5%/year
- Loop Resistance 1000 Ω
- Media Compatibility Clean dry air / inert gas, Clean process / cooling water, Corrosive chemicals / acids / bases, Fuel gases, HVAC / room air, Hydraulic fluids, Inert / non-reactive gases, Liquids, Oils / lubricants, Organic solvents, Steam, Non-Corrosive Dry Gases, Oil, Oxygen, Solvents, Water, Water-based fluids
- Output Detail Field selectable
- Power Consumption max 40 mA
- Measurement Pressure Type Differential
- Process Connection Size 1/8 in
- Process Connection Type NPT Female
- Response Time 1 to 5 s
- Response Time Note 1 to 5 s (selectable)
- Series ID Series-WWDP
- Span Adjustment Menu Option
- Supply Power Type AC/DC
- Supply Voltage 12 to 30 Vdc/18 to 28 Vac
- Thermal Effects 2% FS/100°F
- Thermal Effects Note 2% FS/100°F (50°C) includes zero and span
- Weight 680.4 g
- Zero Setting Adjustable Range Digital “re” zero button (should be used when changing ranges)
Supported Applications
The Dwyer Series WWDP Wet-to-Wet Differential Pressure Transmitter is designed for measuring the flow of various liquids and gases, pressure drop across filters, liquid level in pressurized vessels, and use in energy management and process control systems. The series provides field-selectable unidirectional and bidirectional pressure ranges to accommodate diverse installation requirements.
Operating Conditions & Performance
The Series WWDP operates within a compensated temperature range of 32 to 130°F (0 to 54°C) with an operating temperature range of -4 to 185°F (-20 to 85°C). Accuracy is specified as ±1% FS for all pressure ranges, except the lowest selectable range of each unit which is ±2% FS. Stability is rated at ±0.5% per year.
Pressure limits vary by model: WWDP-1 has a max working pressure of 50 psi; WWDP-2 supports up to 100 psi; and WWDP-3 handles up to 250 psi. The series features a proof pressure rating of 2.2X of FS and a burst pressure of 40X of FS. Response time is selectable between 1 to 5 s.
Configuration Options
The Series WWDP offers three primary models (WWDP-1, WWDP-2, WWDP-3) with optional LCD display versions for on-site indication of line and differential pressure. The series supports the following configurable features:
- Pressure Ranges: Field-selectable unidirectional and bidirectional ranges including 5, 10, 25, 50 psid (WWDP-1); 10, 20, 50, 100 psid (WWDP-2); and 25, 50, 125, 250 psid (WWDP-3).
- Output Signals: Configurable outputs include 0-5 VDC, 0-10 VDC, 1-5 VDC, and 4-20 mA.
- Housing & Connections: All cast aluminum housing rated NEMA 4 (IP66) with a 1/8" female NPT internal process connection and 1/2" conduit electrical connection.
- Materials: Wetted materials are compatible with gases or liquids suitable for 316 SS; the manual also references compatibility with 17-4 PH stainless steel.
- Special Features: Includes auto-zero capability and a field-selectable port swap feature to eliminate costly replumbing if improperly installed. An optional NIST traceable calibration certificate is available (order code: NISTCAL-PT1).
Key Product Differences
The series distinguishes between standard models and LCD-equipped variants:
- WWDP-1 / WWDP-1-LCD: Max working pressure 50 psi; selectable ranges of 5, 10, 25, 50 psid.
- WWDP-2 / WWDP-2-LCD: Max working pressure 100 psi; selectable ranges of 10, 20, 50, 100 psid.
- WWDP-3 / WWDP-3-LCD: Max working pressure 250 psi; selectable ranges of 25, 50, 125, 250 psid.
All models share the same enclosure rating and mounting orientation requirements: vertical mount with pressure ports down to prevent debris buildup. The unit is not field serviceable and must be returned for repair if needed.
PDFs & Manuals
Accessories
Static Pressure Sensors for Manometers & Gages across Air Filters
From C$3.77
0 In Stock
Industrial Control: Pressure Gauges, Flow Meters & Temp Controllers
From C$5.15
0 In Stock
Gage Guard for Pressure/Vacuum, Polypropylene, Inorganic Compatibility
From C$154.37
0 In Stock
calibration
Show Ratings & Reviews