  • 316 SS Housing
  • ± 1% RH Accuracy
  • ± 0.5°C (1.0°F) Temperature Accuracy
  • High Temperature [120°C (248°F)]
HX80A-Srs-TRH-BP-Sig-Cond
From C$ 1,784.21
Models In Stock
Wall, Remote, or Duct Mount Temperature, Relative Humidity, Dew Point, or Barometric Pressure Transmitters HX80A-Srs-TRH-BP-Sig-Cond HX80A-Srs-TRH-BP-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 0.5 °C (± 0.9 °F)
  • Cable Length 1.8 m
  • Data Interface RS232
  • Data Interface Note RS232C (bi-directional) to DTE device, 19.2 kilo baud, 8 bits data, 1 stop bit, no parity
  • Filter Sinter Stainless Steel
  • Current, Max 50 mA
  • Pressure Limits Up to 690 psi
  • Pressure Note 317 kg (700 lb) (47.6 bar)
  • Probe Diameter 19 mm
  • Probe Length 203 mm
  • Process Connection Size 3/4 in
  • Process Connection Type NPT Male and Female
  • Relative Humidity 5 to 95%
  • Relative Humidity Accuracy ± 1.0 % RH
  • Sensor Material Stainless Steel
  • Series ID HX80A-Srs-TRH-BP-Sig-Cond
  • Supply Voltage 18 to 30 Vdc
  • Temperature Measurement, Max 120 °C
  • Temperature Measurement, Min -20 °C
  • Time Constant <15 sec, air flow dependent (for 66.6% response)
  • Weight 0.9 kg

Supported Applications

The Omega HX80A Series comprises precision transmitters designed for the measurement of relative humidity, air temperature, dew point, barometric pressure, and high process pressure. The series is engineered for use in environmental chambers, compressed air systems, and general industrial applications requiring remote sensing.

  • Environmental chamber monitoring
  • Compressed air quality verification
  • Industrial process humidity and temperature control

Operating Conditions & Performance

The HX80A Series operates within a defined measurement envelope across its various configurations. Relative humidity is measured from 5 to 95% RH with an accuracy of ±1% RH, while air temperature ranges from -20 to 120°C (-4 to 248°F) with an accuracy of ±0.5°C (1.0°F). The response time for the sensor is less than 15 seconds in still air conditions.

Specific pressure models extend the measurement capability: barometric pressure ranges from 750 to 1100 mb with ±5 mb accuracy, and high-pressure variants measure up to 200 psia (with a maximum pressure rating of 317 kg / 47.6 bar) at an accuracy of ±0.75 psi. Dew point models cover -60 to 40°C (-76 to 104°F). The probe features a removable, cleanable sintered stainless steel filter and is constructed from stainless steel.

Configuration Options

The series offers configurable mounting styles including remote mount probes with cable, wall-mounted units, and duct-mounted configurations. Output signals are provided via three analog channels plus an RS-232 serial port (bi-directional, 19.2 kbaud). Models differ in output type: HX85A variants provide 0 to 10 Vdc outputs, while HX86A variants deliver 4 to 20 mA signals into a maximum load of 500 Ω.

Mounting and Housing Options

  • Remote Mount: Probe with 1.8 m (6 ft) cable; sensor only or with electronics module options.
  • Wall Mount: Integrated housing for direct wall installation.
  • Duct Mount: Designed for insertion into ductwork applications.

Sensor and Output Configurations

  • HX85A / HX86A: Relative Humidity, Temperature, Dew Point (-60 to 40°C).
  • HX85BA / HX86BA: Relative Humidity, Temperature, Barometric Pressure (750 to 1100 mb).
  • HX85PA / HX86PA: Relative Humidity, Temperature, High Process Pressure (0 to 200 psia).

Additional Features

  • LCD Display: Available on HX86A series models and the optional HX86A-DIS remote electronics module.
  • Alarm Relays: Two Form A (SPST, NO) relays rated at 3 A/250 Vac are included in HX86A variants.
  • Field-Replaceable Sensors: Options include HX80-SENSOR (RH/Temperature), HXP80-SENSOR (RH/Temperature/Pressure), and HXB80-SENSOR (RH/Temperature/Barometric Pressure).

Key Product Differences

The primary distinction within the series lies between the sensor-only models (HX85A, HX85BA, HX85PA) which provide 0 to 10 Vdc outputs and require an external display or controller, and the integrated transmitter models (HX86A, HX86BA, HX86PA). The HX86 series includes a built-in LCD digital display, two programmable alarm relays, and provides three 4-20 mA analog outputs. Mounting variations are denoted by suffixes: "W" indicates Wall Mount (e.g., HX86A-W) and "D" indicates Duct Mount (e.g., HX86A-D). The series supports a power supply range of 18 to 30 Vdc unregulated.

Accessories

accessories

SAMPLE CHAMBER
C$821.40 / each
0 In Stock
REMOTE MODULE 2-LINE LCD DISPL
C$1,067.83 / each
0 In Stock
ADAPTER BOARD
C$186.37 / each
0 In Stock
DC POWER SUPPLIES
C$135.07 / each
31 In Stock

sensors

FIELD REPLAC SENSOR MODULE
C$1,127.42 / each
0 In Stock
FLD REPLACE SENSOR MODULE
C$959.55 / each
0 In Stock
FIELD REPLAC SENSOR MODULE
C$959.55 / each
0 In Stock
Rated 5 out of 5 by from Excited with all the functionalities Looking forward o using the analog output that can be read continuously.
Date published: 2023-04-21
  • y_2026, m_9, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_HX85A, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Using Putty , I do get the following by manually entering T , H or D However I do not get any result when I enter P for Pressure ?!

Asked by: vkarimi
Thank you for your inquiry. You should be using the letter &quot;B&quot; for Barometric Pressure.
Answered by: Application Engineer CB
Date published: 2021-10-15

Do you have any additional data for time constant vs air flow, and is there maximum allowable flow speed?

Asked by: Phoenix
Hi Phoenix, Thank you for the inquiry. Please forward this question to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-05-19

Is a longer cable available?

Asked by: Gg42
Hi Gg42, Thank you for the inquiry. Please forward your request to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-03-14

Will this unit operate in a low pH environment, pH range 2.0 to 6.0 standard units? Will this unit operate after exposure to a spray water flush of 5 minutes?

Asked by: WW Operator
Thank you for the inquiry. This unit is designed for non condensing environment only. Air with mist, particulates, or oils are not suitable application for the sensor. Probe will not function in wash down environment. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-04-23

What is the IP rating on the unit and on the probe?

Asked by: DavisControls_Charles
Thank you for the inquiry. Electronics housing is rated IP66. For details on the sensor please forward your question to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-01-23

Does the unit come with a NIST traceable certificate?

Asked by: Davidgr
Thank you for your inquiry. Unit is supplied with NIST certificate.
Answered by: Application Engineer JB
Date published: 2023-03-16
  • y_2026, m_9, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_6
  • loc_en_CA, sid_HX85A, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration