CL543B-series

Thermocouple, Millivolt and RTD Calibrator and Thermometer

Models In Stock
  • Calibrate Thermocouple Instruments to 0.1 and 0.01, °F and °C
  • Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), (T-DIN) and P (Platinel): -13.000 to 80.000 mV
  • Calibrate RTD Instruments to 0.1 and 0.01, °F and °C
  • Pt 10, 50, 100, 200, 500 and 1000 (3850)
CL543B-series
From C$ 3,394.01
Models In Stock
Thermocouple, Millivolt and RTD Calibrator and Thermometer CL543B-series CL543B-series
loading all models
Product Overview
  • Additional Features 1 Read and Source Signals
  • Alerts Red LED displays OVERLOAD or out of range conditions
  • Battery life 50 hr, low battery warning with less than 1 hr operation left
  • Cold Junction Sensor ≤± 0.01% °/ ° from ambient temperature ( °C or °F)
  • Display Type LCD
  • Display Type Note High contrast graphic Liquid Crystal Display. LED backlighting for use in low lit areas.
  • Height 41 mm
  • Length 143 mm
  • Operating Temperature, Min -20 °C
  • Over-Voltage Protection Up to 60 vrms (rated for 30 seconds), protection against misconnection
  • Relative Humidity, Max 0.9
  • Relative Humidity, Min 10%
  • Relative Humidity Note 10% ≤RH ≤90% (0 to 35°C),non-condensing; 10% ≤RH ≤70% (35 to 60°C),non-condensing
  • RTD and OHMS Read Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 Accuracy: ± (0.015% of reading + 0.05Ω) Excitation Current: 0.9 mA to 401Ω, 0.4 mA to 4010Ω (nominal)
  • RTD and OHMS Source 3- and 4-Wire Accuracy: From 1 to 10.2 mA External Excitation Current: ± (0.015% of setting + 0.05Ω) Below 1 mA of External Excitation Current: Add (0.025 mV/mA excitation current) 2-Wire Accuracy: Add 0.1Ω to 3-wire and 4-wire accuracy Resistance Ranges: 400Ω Range: 0.00 to 401.00 and 0.000 to 401.000 4000Ω Range: 0.0 to 4010.0 and 0.00 to 4010.00 RMS Noise: 400Ω Range: ≤± 0.005Ω from 0.1 to 10 Hz 4000Ω Range: ≤± 0.05Ω from 0.1 to 10 Hz Allowable Excitation Current Range: 400Ω Range: 10.2 mA max; steady or pulsed/intermittent 4000Ω Range: 1 mA max; steady or pulsed/intermittent Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width, 0.025 mV, mA excitation current
  • Series ID CL543B-series
  • Storage Temperature, Max 60 °C
  • Storage Temperature, Min -30 °C
  • Supply Voltage 6 Vdc
  • Temperature Effect ≤± 25 ppm/°C
  • Thermocouple Type J, K, T, E, N, R, S, U, B, G, C, D, L, P
  • Voltage Read Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of reading + 0.006 mV) Input resistance: ≥10 MΩ Normal Mode Rejection: 50/60 Hz,50 dB Common Mode Rejection: 50/60 Hz,120 dB
  • Voltage Source Ranges and Resolution: -13.000 to 80.000 mV and -13.0000 to 80.0000 mV Accuracy: ± (0.008% of setting + 0.006 mV) Source Current: ≥10 mA Output Impedance: <0.3Ω RMS Noise: ≤± 0.0005 mV from 0.1 to 10 Hz Short Circuit Duration: Infinite
  • Weight 0.34 kg
  • Weight Note 0.34 kg (12.1 oz) with boot and batteries
  • Width 76 mm

Supported Applications

The Omega CL543B is a handheld thermocouple and RTD calibrator designed for high-accuracy automated temperature calibration in plant, field, or shop environments. The device supports heat treating surveys, accuracy tests, and troubleshooting of RTD sensors with automatic detection of 2-, 3-, or 4-wire connections.

It is capable of verifying resistance, cold junction temperature, and output signals for a wide range of sensor types:

  • Thermocouples: Types J, K, T, E, R, S, B, N, G (W), C (W5), D (W3), P, L (J-DIN), and U (U-DIN).
  • RTDs: Pt 10Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1000Ω; Cu 10Ω, 50Ω; and Ni 120Ω.

The CL543B meets or exceeds the requirements of AMS 2750 as both a secondary standard instrument and a field test instrument. It includes NIST certification (no points).

Operating Conditions & Performance

The series operates within an ambient temperature range of -20 to 60°C (-4 to 140°F). Storage is supported from -30 to 60°C (-22 to 140°F). Humidity limits are defined as 10% ≤ RH ≤ 90% (non-condensing) at 0 to 35°C, and 10% ≤ RH ≤ 70% (non-condensing) at 35 to 60°C.

Performance specifications vary by sensor type and range. General accuracy is stated as ±(0.008% of reading + 0.006 mV) for thermocouples and voltage, and ±(0.015% of reading + 0.05Ω) for 3- and 4-wire RTDs.

Specific accuracy values are defined by temperature ranges in the specification tables:

  • Type J Thermocouple: Accuracy varies from ±0.25°C (-200 to -150°C) down to ±0.13°C (-50 to 300°C), and up to ±0.20°C (850 to 1200°C).
  • Type K Thermocouple: Accuracy ranges from ±0.70°C at -230 to -100°C, improving to ±0.19°C between -100 and 600°C.
  • Pt 100Ω RTD (DIN/IEC/JIS): Accuracy is ±0.13°C from -200 to -150°C, ±0.24°C from -150 to 360°C, and increases with temperature up to ±0.37°C at 740 to 850°C.

The cold junction sensor is accurate to ±0.05°C. Measurement ranges span -200.00 to 2320.00 °C (-328.00 to 4208.00 °F) for temperature, and 0.00 to 4010.00 Ω for resistance.

Configuration Options

The CL543B features a rugged design with a rubber boot enclosure, low-profile switches, brass screws, and an integrated kick stand for bench use. The display includes backlighting for operation in dark areas.

Connections:

  • Banana jacks (1+ and 2-) mounted on the top end of the housing; these are not temperature compensated and intended only for millivolt signals.
  • Screw terminal block for thermocouple wire connections.
  • Miniature thermocouple socket with an isothermal block.

Power Supply:

  • Battery: Four 'AA' alkaline 1.5V (LR6) batteries included.
  • Optional NiMH rechargeable battery kit available, including a 120 Vac charger, four NiMH batteries, and AC/DC cords.

Included Accessories:

  • Rubber boot (integrated).
  • NIST Cert (no points).
  • Operator's manual.

Key Product Differences

The series is represented by the single model CL543B, described as a "Thermocouple and RTD temperature calibrator." The device supports multiple thermocouple materials including Iron-Constantan (J), Chromel-Alumel (K), Copper-Constantan (T), Platinum-Rhodium alloys (R, S, B), Tungsten-Re (G, C, D), and Palladium-Gold-Palladium (P).

RTD support includes various alpha coefficients: 1.385 for DIN/IEC/JIS standards; 1.390 for Burns curves; 1.392 for Old JIS 1981; and 1.393 for US Lab specifications.

Optional accessories available separately include a deluxe hands-free carrying case, mV/V test leads (red/black with banana plugs and alligator clips), an RTD wire kit, and red/black leads with spade lugs.

Rated 4 out of 5 by from Works! This device is a resource used by many within our company. It has worked properly when used. Our company monitors the large reciprocating compressors in different Plants around the US and Canada. We lost one we had previously so buying a new one shows it has been a great tool.
Date published: 2023-02-09
Rated 5 out of 5 by from Themocouple calibrator I bought this calibrator earlier this summer. It is easy to use. You easily go between the read and simulation functions. I use it a lot for troubleshooting temperature issues on various pieces of equipment.
Date published: 2018-11-07
  • y_2026, m_7, d_31, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_CL543B, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Does the CJC accuracy affect the uncertainty calculations above the stated accuracy of 0.2 C? Or is the CJC accuracy part of that &quot;accuracy&quot; value? Could you provide the &quot;Type B&quot; Uncertainty for this meter?

Asked by: Erik
Hi Erik Thank you for the inquiry. CJC accuracy is in addition to thermocouple accuracy. Need to add the two for total measure or simulate accuracy. Type B accuracy is listed in manual. Sorry cannot calculate the uncertainty for you. Best regards OMEGA
Answered by: NorwalkAE
Date published: 2020-07-14

I am looking to buy one and need to know how much and how long it will take to get it with CAL-3 calibration certificate

Asked by: Marco KAMAN
Hi Marco Thank you for the inquiry. For current price and lead time please email request to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-04-23
  • y_2026, m_7, d_30, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_CL543B, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration