Models In Stock
  • ± 0.5°C (± 0.9°F) Accuracy
  • Multiple Start/Stop Function
  • Ultra High Speed Download
  • Memory: 1 Million Readings
OM-CP-TEMP101A-Logger
From C$ 201.15
Models In Stock
Temperature Data Logger, Part of the NOMAD Family OM-CP-TEMP101A-Logger OM-CP-TEMP101A-Logger
loading all models
Product Overview
  • Alarm Note Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits
  • Battery life up to 10 yr
  • Battery Size and Type 3.6V Li-ion
  • Calibration Digital calibration through software
  • Data Interface USB
  • Data Interface Note USB (interface cable required); 115,200 baud
  • Height 16 mm
  • LED Indicators Green LED Blinks: 10 second rate to indicate logging 15 second rate to indicate delay start mode; Red LED Blinks: 10 second rate to indicate low battery and/or full memory 1 second rate to indicate an alarm condition
  • Length 56 mm
  • Measurement Type Humidity, Pressure, Temperature
  • Memory 2000000
  • Memory Note 2,000,000 readings; software configurable memory wrap; 660,000 readings in multiple start/ stop mode
  • Number of Measurements 1
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Real Time Recording The device may be used with PC to monitor and record data in real-time
  • Relative Humidity, Max 0.95
  • Relative Humidity, Min 0%
  • Samples,Max 670000
  • Sampling Rate 1 Hz (1 update/second)
  • Sampling Rate Note 1 reading every second to 1 every 24 hours.
  • Series ID OM-CP-TEMP101A-Logger
  • Start Modes Adjustable Delay Start, Immediate Start, Push-button
  • Supply Power Type Battery
  • Temperature Accuracy ± 0.5 °C
  • Temperature Measurement, Max 80 °C
  • Temperature Measurement, Min -40 °C
  • Temperature Resolution 0.01 °C
  • Temperature Sensor Type RTD
  • Temperature Sensor Type Note Precision RTD Element
  • Time Accuracy ± 1 minute/month @ 20 °C
  • Weight 24 g
  • Width 36 mm

Supported Applications

The Omega OM-CP-TEMP101A is a battery-powered temperature data logger within the NOMAD® family, designed for recording and monitoring thermal conditions. The device features real-time operation capabilities via Windows software compatibility, allowing users to export logged data to Microsoft Excel or print in tabular format.

Operating Conditions & Performance

The OM-CP-TEMP101A operates across a temperature range of -40 to 80°C (-40 to 176°F) with an accuracy of ±0.5°C (±0.9°F). It utilizes a precision RTD sensing element and provides a resolution of 0.01°C (0.018°F). The unit functions in ambient humidity conditions from 0 to 95% RH non-condensing.

Power is supplied by an included, user-replaceable 3.6V lithium battery with a typical life of 10 years at a 15-minute reading rate. Time accuracy is specified as ±1 minute/month at 20°C (60°F). The device includes a memory capacity for 2 million readings and supports software-selectable memory wrap-around.

Key Performance Specifications

  • Measurement Range: -40 to 80°C (-40 to 176°F)
  • Accuracy: ±0.5°C (±0.9°F)
  • Resolution: 0.01°C (0.018°F)
  • Battery Life: 10 years typical at a 15-minute reading rate
  • Memory Capacity: 2 million readings

Configuration Options

The series supports configurable options for certification, software connectivity, and battery replacement. The device is housed in ABS plastic with overall dimensions of 56 L x 36 W x 16 mm D (2.2 x 1.4 x 0.6") and weighs 24 g (0.8 oz).

Available Options & Accessories

  • NIST Calibration: OM-CP-TEMP101A-CERT includes a NIST calibration certificate.
  • Data Interface: OM-CP-IFC200 provides Windows software and a 1.8 m (6') USB interface cable required for operation, data retrieval, and firmware upgrades.
  • Battery Replacement: OM-CP-BAT105 is the replacement 3.6V lithium battery.

The device features a multiple start/stop mode activated by pressing and holding the pushbutton for 5 seconds. Additional capabilities include programmable high/low alarms, optional password protection, and a battery life indicator. Free firmware upgrades are available via PC without returning to the factory.

Key Product Differences

The primary model OM-CP-TEMP101A is the standard temperature data logger. The variant OM-CP-TEMP101A-CERT distinguishes itself by including a NIST calibration certificate at the time of order. Data retrieval and configuration require the separate purchase or inclusion of the OM-CP-IFC200 software package, which converts the PC into a real-time strip chart recorder.

Accessories

cables

USB INTERFACE CABLE
C$295.35 / each
35 In Stock

consumables

3.6V LITHIUM BAT 750 MAH
C$46.12 / each
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

NIST calibration period is valid one year of what? one year from calibration date ? or one year form activation date?

Asked by: SAMO
One year from date of calibration
Answered by: cwengineer3
Date published: 2020-01-31

How long is the NIST calibration period?

Asked by: Michael S
It is valid for one year. Thank you.
Answered by: Application Engineer
Date published: 2019-07-15

Does Omega offer NIST traceable, recalibration services for the OM-CP-RHTemp101A, and OM-CP-Temp101A loggers? If so what is cost per unit, and typical turnaround time? Thank you.

Asked by: RNC01
Thank you for your question. Yes, we do. You must e-mail Customer Service at CSERVICE@OMEGA.COM and they will provide cost and lead time.
Answered by: Application Engineer PV
Date published: 2022-11-11

I need to purchase 2 of these, would the Windows software and 1.8 m (6') USB interface cable work for both? or do I need to purchase separately?

Asked by: Gonzabre
Yes, the software/USB cable pack will work for both of the loggers. You would just have to set them up / download data from them one at a time.
Answered by: JA Engineer
Date published: 2021-11-01

What connectors are needed on the thermocouplers to fit this datalogger?

Asked by: Rawjer
Hi Rawjer No connections are needed. This unit has internal temperature sensor for logging ambient temperatures. The OM-CP-TC101A has Female SMP style connector for thermocouple input. Best regards OMEGA
Answered by: NorwalkAE
Date published: 2020-10-15
  • y_2026, m_8, d_2, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_OM-CP-TEMP101A, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 14ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration