Skip to search Skip to main content Skip to navigation

Netherlands 07077 03815 | Intl +31 (0) 7077 03815 | Welcome to our new website, found an issue or bug? Please report it here

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FLR1000-Series

Stainless Steel Low Flow Turbine Flow Meter with Optional Display

Models In Stock
  • 0 to 5 Vdc Linear Output Signal
  • Power Input 12 Vdc or 24 Vdc (depending on the model)
  • Ranges from 20 to 100 ml/min, 100 to 500 L/min
  • 1% Accuracy for Liquids/3% Accuracy for Gasses
FLR1000-Series
From C$ 618.20
Models In Stock
Stainless Steel Low Flow Turbine Flow Meter with Optional Display FLR1000-Series FLR1000-Series
loading all models
Product Overview
  • Cable Length 3 ft
  • Electrical Connection Four-Pin
  • Height 3.5 in
  • Length 3 in
  • Mounting #4 Screw
  • Number of Digits 3.5
  • Operating Pressure Note 40 psi at 20°C (68°F)
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Output Detail 0 to 5 Vdc, adjustable ±20% (typical)
  • Repeatability Note ±0.5% FS from 50 to 100% of rated maximum flow for gas
  • Series ID FLR1000-Series
  • Storage Temperature, Max 70 °C
  • Storage Temperature, Min 0 °C
  • Supply Current 30 mA
  • Temperature Effect ±0.2%/°C
  • Width 1.75 in

Supported Applications

The Omega FLR1000 Series and FLR1000ST Series are low flow turbine meters designed for measuring extremely low flow rates from 20 mL/min to 5 L/min. These sensors are suitable for industrial, commercial, and laboratory applications involving liquid or gas media.

Operating Conditions & Performance

The series delivers an accuracy of ±1% FS (liquids) and ±3% (gases), with repeatability specified as ±0.2% FS for liquids and ±0.5% FS for gases. The FLR1000 Series operates within a process temperature range of 0 to 50°C (32 to 122°F). For the stainless steel construction, the FLR1000ST Series supports an ambient operating temperature of 5 to 55°C (41 to 131°F) and storage temperatures from 0 to 70°C (32 to 158°F).

Pressure ratings vary by series and media. The FLR1000 Series supports up to 40 psi at 20°C (68°F) for gas, 100 psi for liquid, and 500 psi for brass units using liquid services. The FLR1000ST Series is rated for a maximum of 34 bar (500 psig).

Configuration Options

The series offers extensive configuration options across housing materials, output signals, and display availability.

  • Housing Materials: PPS or Brass Construction for the FLR1000 Series; Stainless Steel Construction (316 SS) for the FLR1000ST Series. Wetted parts include 40% glass filled polyphenelene sulfide, sapphire shaft and bearing, FKM rubber O-rings, Pyrex® glass, epoxy, and stainless steel bearing support.
  • Output Signals: Models are available with Pulse Output, 0 to 5 Vdc, or 4 to 20 mA signals. The FLR1000ST Series includes specific model variants for voltage output (e.g., -D suffix) and current output (e.g., -I suffix).
  • Display Options: Units are offered with or without a display. Display models feature dimensions of 76 x 44 x 89 mm (3 x 1.75 x 3.5"), while non-display units measure 60 x 42 x 37 mm (2.35 x 1.65 x 1.25").
  • Process Connections: Acetal Tube Fittings are available in sizes ranging from 1/8" to 1/2", selected based on the specific flow range model.
  • Electrical Connection: A 4-pin male connector is included with a 0.9 m (3') cable for both power and signal transmission.

Power supply requirements differ by output type: FLR1000 Series requires 11.5 to 15 Vdc regulated, 30 mA typical; Voltage Output Models of the FLR1000ST Series require 11.5 to 12.5 Vdc (0.4 W @ 12 Vdc); Current Output Models of the FLR1000ST Series require 18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA.

Key Product Differences

The series is divided into two primary construction families: the standard FLR1000 and the stainless steel FLR1000ST. The FLR1000 Series utilizes a Pelton-type turbine wheel with an electro-optical system for gas flow measurement, while the FLR1000ST Series provides stainless steel wetted parts.

Model numbering distinguishes between media type and output configuration:

  • Gas Models (FLR1001–FLR1206): Cover flow ranges from 20 to 100 mL/min up to 40 to 200 L/min. These models are available with optional brass body (-BR) and display options.
  • Liquid Models (FLR1007–FLR1013): Cover flow ranges from 13 to 100 mL/min up to 1 to 10 L/min. These models offer pulse output (-P), brass body (-BR), and display options.
  • Liquid Stainless Steel Models (FLR1007ST–FLR1013ST): Provide the same liquid flow ranges as FLR1007-1013 but with 316 SS construction. Variants include no display, voltage output (-D), and current output (-I).

Optional accessories include power supplies (FLR1000-PW for 115 Vac, FLR1000-230PW for 230 V with European connector) and replacement cables. Calibration options are available by adding the suffix “-NISTAIR” for a 4-point NIST calibration for air or “-NISTWATER” for water (FLR1007 calibrations are 3-points).

Accessories

cables

3' CABLE ASSEMBLY
€ 70,92 / each
0 In Stock

meters/controllers

1/8 DIN Thermocouple and RTD Panel Meter with Large, Selectable Color Display
€ 491,22 / each
0 In Stock
Analog Input Ratemeter/Totalizer
€ 468,19 / each
1 In Stock
i-Series 1/32, 1/16, 1/8 DIN Programmable Temperature/Process Meters with RS232 & RS485 Communications
€ 407,84 / each
0 In Stock
Frequency Input Ratemeter/Totalizer
SGD782.30 / each
0 In Stock
230V POWER SUPPLY W/EUROPE CON
SGD222.11 / each
0 In Stock
115VAC POWER ADPT FOR FLR1000S
SGD210.24 / each
4 In Stock
Rated 4 out of 5 by from These work as expected We have used these in the past, so we know what to expect.
Date published: 2016-06-21
Rated 5 out of 5 by from Recommend to other other users. Great Product Recommend to other other users. Great Product with very good quality.
Date published: 2025-02-07
Rated 5 out of 5 by from Digital Flow Sensor This flow sensor that I bought works well. The display makes it very convenient to control the flow rate. I highly recommend it.
Date published: 2023-07-26
Rated 5 out of 5 by from Easy and Reliable We have several of these FLR series flow meters in the lab. They are easy to use, and very reliable.
Date published: 2023-04-01
Rated 5 out of 5 by from Perfect The flowmeter works perfectly out of the box as advertised.
Date published: 2023-02-05
Rated 1 out of 5 by from VERY POOR! Wrong Reading! Bought this flowmeter and tested it (measuring cylinder and timer)only to realise the reading was way off the mark. Please be careful, look for a calibration certification if you plan to get one.
Date published: 2022-02-18
Rated 4 out of 5 by from C+ to B- FLR1204 20-100L/min works. Spec sheet states "fast response" I did not find this to be true. Power requirements states 30mA (typical) with 11.5 V to 15.0 V supply, so 0.345 W to 0.45 W. Data logger has .4 W. Will data logger power the senor or not??? Also, the FLR1204 sensor is on a by-pass plumbing, I was not aware of this.
Date published: 2021-02-27
Rated 3 out of 5 by from works and functions but limited Purchased unit but had to return the first one due to a defect on the screen. got the second one in and it works great, in an environment without any back pressure. The second any pressure is added to the mix the gauge is rendered useless. unfortunately the testing we are performing requires some pressure while still maintaining flow and we are not able to get the value we are looking for. looking at other gauges that might have a different system to make our test work.
Date published: 2019-04-10
  • y_2026, m_8, d_13, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_10
  • loc_en_CA, sid_FLR1001, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

What is the Mfr and P/N of the electrical connector? Or, better yet, the mating connector/crimps?

Asked by: Pablo
Thank you for your question? We do not sell the connector alone. If you are looking for the power supply connector, the part number for the connector and cable is FLR1000-PW for 120VAC, or FLR1000-230PW for 230VAC. If you are looking for the communication cable connector, the part number for the connector and cable is FLR1000-C.
Answered by: application engineer je
Date published: 2019-07-08

The user's guide / manual for these units (FLR1003 / FLR1203) indicate Viton O-rings as standard, but EPDM optional. Can I order the EPDM option?

Asked by: SeanS
Yes. Add suffix "-EPDM" to the part number for the EPDM O ring option.
Answered by: ASE HPO
Date published: 2019-10-22

We would like to check if FLR1011 can be applied to measure Refrigerant, including R1233zd, R1234ze and R134a. Pls kindly advise asap.

Asked by: Winnie123
The FLR1000 uses infrared (IR) technology, so the liquid must be translucent for proper operation. The wetted components are listed in the data sheet. Please ensure they are compatible with the fluid in your application.
Answered by: HPOAE
Date published: 2026-03-02

Will this work with a coolant liquid at -10 C? The coolant is glycol-water mix.

Asked by: MarcA
Thanks for your question. The FLR1000 series meters have an operation temperature range of 5-55 C and a storage temperature range of 0-70 C. This meter cannot handle -10 C temperatures.
Answered by: Jane
Date published: 2019-06-19

Will this work with automotive liquids such as gasoline, diesel? If not can you suggest an alternative low flow rate meter.

Asked by: tempest
Thank you for your inquiry! These flow meters incorporate infrared light into the measurement of flow rate and thus require that all fluids be translucent. Additionally, they are calibrated with water and will deviate with viscosities varying from water. Though suitable for up to 10 centistokes, accuracy may be affected by the combination of these factors. The FLR series would still be our best suited option as we do not have another offering with a similar flow range and analog output.
Answered by: Application Engineer JM
Date published: 2024-04-25

What is the confidence level of the reported accuracy specification on these flow meters?

Asked by: ConnerZ
Thank you for your inquiry and unequivocally 100%
Answered by: Applications Engineer JJC
Date published: 2025-01-16

What is the pinout for this sensor in a 4-20 mA model? P/N FLR1009ST-I. Thank you.

Asked by: Stingray36
Thank you for your inquiry about the flow meter. The manual outlines the wire schematic flow the "-I' flow meter such as the FLR1009ST-I meter you have. It goes as follows on page 13 of 34. The RED wire should be connected to the Positive of the power source. The BLACK wire should be connected to the Negative ( Ground ) of the power source. The WHITE wire provides the signal output (active current) and should be connected to the positive terminal of the display, data acquisition system or current meter with an impedance of 0 - 500Ω (Ohms). The GREEN wire is NOT used.
Answered by: Application Engineer JC
Date published: 2022-01-05

Can I use this to measure the permeability of prepreg composite under a vacuum bag?

Asked by: Robyn123
Thank you for your inquiry about the flow meter. Unfortunately, it is not recommend to use under vacuum. The FMA1700/1800A mass flow meters for gases can measure flow rate in vacuum conditions.
Answered by: Application Engineer JC
Date published: 2021-11-04
  • y_2026, m_8, d_13, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_en_CA, sid_FLR1001, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-NL
en_CA
Save Configuration