HX92B-Srs-RH-Sig-Cond

Relative Humidity Signal Conditioner/Transmitter with Probe

Models In Stock
  • 4 to 20 mA, 0 to 1 Vdc, 0 to 5 Vdc or 0 to 10 Vdc Outputs
  • Accurate to ± 2.5% (20 to 80% Relative Humidity)
  • Rugged Industrial Splashproof Enclosure NEMA 13 (IP54)
  • Duct Mount Kit Included with Duct Mount and Remote Probe Models
HX92B-Srs-RH-Sig-Cond
From C$ 605.77
Models In Stock
Relative Humidity Signal Conditioner/Transmitter with Probe HX92B-Srs-RH-Sig-Cond HX92B-Srs-RH-Sig-Cond
loading all models
Product Overview
  • Accuracy ± 4 %
  • Cable Diameter 6.73 mm
  • Enclosure Ratings IP54
  • Measurement Type Humidity
  • Relative Humidity 0 to 100% RH
  • Relative Humidity Response Time 8 sec
  • Repeatability ± 0.1% RH
  • Sampling Rate 0.25 Hz (4 seconds between updates)
  • Series ID HX92B-Srs-RH-Sig-Cond
  • Supply Power Type DC
  • Temperature Measurement, Max 75 °C
  • Temperature Measurement, Min -30 °C
  • Wire Gauge 22 to 14 AWG

Supported Applications

The Omega HX92B Series Relative Humidity Signal Conditioner/Transmitter with Probe provides remote and on-site monitoring of relative humidity. The series delivers a linearized and temperature compensated output signal calibrated to a 0 to 100% RH scale, suitable for applications requiring precise environmental sensing.

Operating Conditions & Performance

The HX92B Series operates within a process temperature range of -30 to 75°C (-22 to 167°F). Accuracy varies by humidity level: ±2.5% from 20 to 80% RH, ±3.5% from 5 to 20% and 80 to 95% RH, and ±4% from 0 to 5% and 95 to 100% RH. Repeatability is specified as ±0.1% RH, with a typical response time of 8 seconds.

The enclosure provides NEMA 13 (IP54) protection for the electronics. The digital sensor element is protected by a stainless steel mesh type filter that is easily removable for cleaning. Approvals include CE and UKCA; NIST certification is available as an optional feature.

Configuration Options

The series supports multiple output signal configurations, mounting styles, and probe types to accommodate diverse installation requirements.

  • Output Signals: 4 to 20 mA (scaled for 0 to 100% RH), 0 to 1 Vdc, 0 to 5 Vdc, or 0 to 10 Vdc. Current output models enable placement of the transmitter at a remote location virtually any distance away from the measuring device.
  • Mounting Configurations: Wall mount (standard), Duct mount (-D suffix), and Remote probe (-RP1 suffix).
  • Sensor Probes: Standard short probes, field replaceable remote probes with 3 m (10') cable and M12 connector (TH-RP), or field replaceable short probes measuring 71.88 L mm (2.83") (TH-SP).
  • Housing & Connections: Gray polycarbonate enclosure with a liquid-tight nylon gland featuring a neoprene seal for cables ranging from 2.29 to 6.73 mm (0.09 to 0.265") diameter. Internal connections utilize a 5-position terminal block accepting 14 to 22 gauge wire.
  • Power Supply: Models with 4 to 20 mA, 0 to 1 Vdc, and 0 to 5 Vdc outputs require 9 to 30 Vdc @ 50 mA. The 0 to 10 Vdc output requires 12 to 30 Vdc @ 50 mA.

Key Product Differences

The HX92B Series is differentiated by mounting type, probe configuration, and replaceability of the sensor element:

  • HX92B(*) (Wall Mount): Standard wall mount relative humidity transmitter. Models with suffixes C, V0, V1, or V2 include a field-replaceable sensor probe.
  • HX92B(*)-D (Duct Mount): Duct mount configuration designed for installation in air handling ducts. These models do not feature a replaceable sensor probe and are supplied with an included duct mounting kit.
  • HX92B(*)-RP1 (Remote Probe): Includes a remote probe with 3 m (10') cable and M12 connector. The sensor probe is field-replaceable, and the unit includes a duct mounting kit.

Model numbering follows the pattern HX92B(*) - - , where output codes are C (4 to 20 mA), V0 (0 to 1 Vdc), V1 (0 to 5 Vdc), and V2 (0 to 10 Vdc). Weights vary by configuration: HX92B(*) is 124 g (4.4 oz); HX92B(*)-D is 132 g (4.7 oz); and HX92B(*)-RP1 is 230 g (8.1 oz).

Accessories

accessories

CAL KIT FOR HX92/3,RHCN NACE
C$289.26 / each
8 In Stock

installation hardware

MOUNTING KIT,IND.PROBE
C$29.02 / each
0 In Stock

sensors

REMOTE PROBE M12 3M CABLE LGTH
C$290.70 / each
1 In Stock
SHORT PROBE M12 2.83" LONG
C$290.70 / each
3 In Stock
Rated 5 out of 5 by from Great response time I bought this about a month ago I'm so glad I did.
Date published: 2018-02-05
Rated 5 out of 5 by from Not so great/Excellent! I was not happy with the service department. I called and asked what would be a good replacement for the HX92A, which has been discontinued, and was told that I should order the HX93BDC.. But when I looked it up, it was not at all what I needed, so I went through the Omega catalog and found the HX92B, which is exactly what I needed. I am very happy with the HX92B, as there is no longer any need to check the calibration (not even possible, in fact), and also due to the fact that this model has a replaceable sensor, which is certainly the most likely part to ever fail. It worked perfectly. Thank you!
Date published: 2018-05-18
  • y_2026, m_9, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_HX92BC, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

Is this 4-20mA loop powered. Do I need 4 wires? 2 for analog and 2 for dc power or just 2 for analog that powers the unit also?

Asked by: Brian1
Hi Brian1, Thank you for the inquiry. The HX92BC is a 2 wire loop powered device. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-02-21

Can i order a replacement probe for the HX92BC transmitter?

Asked by: Radius
Hi Radius Thank you for the inquiry. Yes, the replacement probe is available. Part# is TH-SP Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-07-27

Is there any Hysteresis or delay in the switching once humidity is sampled?

Asked by: Fred27
The Humidity is measured continuously and instantly outputs an Analog DC Voltage or Current which is relative to the reading.
Answered by: ApplicationEngineerANB
Date published: 2020-06-22

Does the HX92BV1 come with the probe?

Asked by: Dave_67
Hi, Yes, this is a complete unit. Our Tech Support engineer has emailed you the specification sheet to provide any additional information you may need. Thanks for connecting with Omega.
Answered by: Jane
Date published: 2019-06-25

i would like to know if i need to calibrate the instrument if i use it with plc

Asked by: janick
Thank you for your inquiry. The unit is shipped fully calibrated, no adjustments required.
Answered by: Application Engineer JB
Date published: 2020-02-12
  • y_2026, m_9, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_HX92BC, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 15ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration