Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

LVU500-Series

Reflective Ultrasonic Level Transmitter w/Alarm for Small Tanks

Models In Stock
  • Designed to handle condensing environments
  • Offered in 1.5 m (4.9’) and 3 m (9.8’) measurement ranges
  • Fail-safe diagnostics with 4 selectable relays and signal outputs
  • Narrow 2” (5 cm) beam width for applications with limited space
LVU500-Series
From C$ 798.26
Models In Stock
Reflective Ultrasonic Level Transmitter w/Alarm for Small Tanks LVU500-Series LVU500-Series
loading all models
Product Overview
  • Approvals ul61010_1
  • Beam Width 2 in
  • Cable Length 48 in
  • Cable Type Insulated Shielded
  • Configuration WebCal® PC Windows® USB® 2.0
  • Contact Fail-Safe Open, Closed, Hold Last
  • Diameter 2.9 in
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings NEMA 6 to 30P for 240V
  • Height 4 in
  • Insulation Polyurethane
  • Loop Resistance 500 Ω @ 24 Vdc
  • Materials FKM, Fluoroelastomer, Polycarbonate, Polyvinylidene, Fluoride
  • Mean Hysteresis Selectable
  • Media Compatibility Clean process / cooling water, Corrosive chemicals / acids / bases, Hydraulic fluids, Oils / lubricants, Organic solvents, Solvents, Water, Water-based fluids
  • Memory Non - Volatile
  • Number of Wires 2
  • Operating Pressure, Max 30 psi
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -35 °C
  • Output Signal Current
  • Process Connection Size 2 in
  • Process Temperature, Max 80 °C
  • Process Temperature, Min -40 °C
  • Series ID LVU500-Series
  • Signal fail-safe 4 mA, 20 mA, 21 mA, 22 mA or hold last
  • Signal invert 4 to 20 mA or 20 to 4 mA
  • Supply Voltage 14 to 28 Vdc
  • Switch Rating 60 VA,1A max
  • Switch Type SPST
  • Temperature Compensation Automatic
  • Transducer Type Reflective Ultrasonic

Supported Applications

The Omega LVU500 Series is a reflective ultrasonic level transmitter designed for continuous measurement in small tanks. The series utilizes proprietary Reflective Technology™ to provide reliable distance or range measurements between the transducer and process media, specifically engineered for condensing environments. Documented applications include day tanks, IBCs (Intermediate Bulk Containers), drums, cooling towers, skids, process tanks, and waste sumps.

The series is suitable for measuring chemicals, water, wastewater, and oil, provided the liquids are non-foaming and/or not highly vaporous. The transmitter provides a 4 to 20 mA analog signal output alongside four SPST relays for alarm or control functions in general-purpose classifications.

Operating Conditions & Performance

The LVU500 Series operates within an ambient temperature range of -31° to 140°F (-35° to 60°C) and a process temperature range of -40° to 176°F (-40° to 80°C). The unit features automatic temperature compensation. Pressure ratings are specified at 30 psi (2 bar), with derating applied @ 1.667 psi per degree C above 25 °C.

Performance specifications vary by model range:

  • Lvu501 Range: Measures from 1.5" to 4.9" (3.8 cm to 1.5 m) with an accuracy of ±0.125" (3 mm), a resolution of 0.019" (0.5 mm), and a dead band of 1.5" (3.8 cm).
  • Lvu503 Range: Measures from 4' to 9.8' (10.1 cm to 3 m) with an accuracy of ±0.2% of range, a resolution of 0.039" (1 mm), and a dead band of 4" (10.1 cm).

Both models share a beam width of 2" (5 cm). The enclosure is rated IP68 / NEMA Type 6P.

Voltage & Signal Specifications

  • Power Supply: 14-28 VDC with maximum consumption of 0.5W.
  • Loop Resistance: 500 ohms @ 24 VDC.
  • Analog Output: 4 to 20 mA, two-wire; configurable for signal invert (4-20 mA or 20-4 mA).
  • Fail-Safe Options: Signal fail-safe can be set to 4 mA, 20 mA, 21 mA, 22 mA, or hold last value.

Contact Specifications

  • Type: (4) SPST relays rated at 60 VA, 1A maximum.
  • Fail-Safe Behavior: Configurable for power loss to hold last value; contact fail-safe options include open, closed, or hold last on power-on.
  • Hysteresis: Selectable per relay configuration.

Configuration Options

The LVU500 Series offers configurable process connections and interface options to accommodate specific installation requirements. The housing is constructed from Polypropylene (PP-FR GF30), while the transducer element utilizes Polyvinylidene Fluoride (PVDF). Electrical connectivity is provided via a 9-conductor, shielded cable with a polyurethane jacket.

Process Connections & Mounting

The series supports two primary process mount configurations:

  • NPT Thread: 2" NPT connection (standard for models LVU501 and LVU503).
  • G Thread: 2" G connection, which includes an FKM gasket.

Additional mounting accessories are available to extend installation flexibility, including bulkhead fittings in PVC (schedules 40 and 80) for various thread/socket combinations ranging from 3" to 4", as well as side mount brackets made of Polypropylene for both NPT and G threads.

Configuration & Interface

The transmitter features non-volatile memory and is configured via WebCal® PC Windows® software using a USB interface. Variants are available with or without the included LVU500-USB FOB (Fob) for programming:

  • With Interface: Models ending in no suffix or "G" include the Fob.
  • Without Interface: Models suffixed with "B" are supplied without the USB interface.

Key Product Differences

The LVU500 Series is differentiated primarily by measurement range and process connection type, resulting in distinct physical dimensions for each model family. The series includes eight enabled variants covering all combinations of range (LVU501 vs. LVU503), thread standard (NPT vs. G/BSPP), and USB interface inclusion.

Model Dimensions

The physical footprint varies between the short-range and long-range models:

  • Lvu501 Family: Height 1.75" (44.5 mm), Width 2.9" (73.7 mm), Diameter 1.5" (38.1 mm).
  • Lvu503 Family: Height 4.0" (101.6 mm), Width 2.75" (69.9 mm), Diameter 1.96" (49.8 mm).

The cable length is specified as 4' (121.9 cm) for the series, with a diameter of 1.875" (47.6 mm). The internal wiring includes dedicated conductors for power (+/-), transmit/receive signals, and four relay outputs plus common.

Compliance & Approvals

The LVU500 Series carries CE and RoHS compliance markings. Additionally, the series meets UL 61010-1 standards for safety in laboratory equipment environments.

Accessories

accessories

LVU500/LVU700 FOB for programming transm
C$104.36 / each
0 In Stock

installation hardware

3 NPT X 2 NPT for Schedule 80
C$147.98 / each
0 In Stock
Side Mount Bracket
C$97.72 / each
0 In Stock
2 G bracket
C$97.72 / each
0 In Stock
2 NPT BULKHEAD FITTING
C$182.35 / each
0 In Stock
3 NPT Bulkhead fitting
C$325.97 / each
0 In Stock
3 NPT X 2 NPT for Schedule 40
C$85.92 / each
0 In Stock
3 in Socket X 2 NPT for Schedule 40
C$34.66 / each
0 In Stock
3 in Socket X 2 NPT for Schedule 80
C$217.71 / each
0 In Stock
4 NPT X 2 NPT for Schedule 80
C$266.71 / each
0 In Stock
4 in Socket X 2 NPT for Schedule 80
C$387.50 / each
1 In Stock
Rated 5 out of 5 by from A better alternative to floats Works as expected. Being used for heated water tank level control. No issues with condensing liquid.
Date published: 2020-06-01
  • y_2026, m_8, d_11, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_LVU501, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 8ms
  • REVIEWS, PRODUCT

Is the FOB used on the LVU501 the same FOB that is used on the LVCN318?

Asked by: Pilot Plant Tech
Thank you for your inquiry about the ultrasonic level sensor. Unfortunately, no.
Answered by: Applications Engineer JC
Date published: 2021-04-07

Hi, what recommended display could you propose me for used with this sensor , because this tank have 15' and I need read the level in the ground.

Asked by: Luis2alonso
Thank you for your inquiry! Our platinum series meters are universal input meters and will operate with the 4-20 mA output from the LVU500 series. These meters can be configured to have different sizes and outputs based on your specific needs.
Answered by: Application Engineer JM
Date published: 2021-05-28

Is the IP rating sufficient for outside mounting on top of a silo exposed to rain/snow? Media level being measured is sawdust. Thank you.

Asked by: PTSchram
Thank you for your inquiring for this level sensor. It does have a IP6 rating that provides outdoor protection to a degree, yet, unfortunately, this sensor is meant to measure liquids, not solids. Please email flow@omega.com and can provide other level sensors for solid measurement.
Answered by: JC ENGR
Date published: 2020-07-30

we want to purchase level transmitter for use on caustic closed tank and HNO3 Closed tanks. please suggest us the model which is compatible to these liquids. range of tanks are upto 5meters.

Asked by: abdul latid
send us all this information to flow@omega.com. We will review and get back to you via email. Thanks.
Answered by: ASE HPO
Date published: 2020-07-21
  • y_2026, m_8, d_10, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_LVU501, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration