1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
								PX35
Pressure Transducers with Premium Temperature Compensation
- Absolute and Gage Pressure, 15 to 30,000 psi
 - Premium Temperature Compensation
 - All Stainless Steel Construction
 - Hermetically Sealed for Harsh Environments
 
Product Overview
	- Accuracy ± 0.25 %
 - Accuracy Class 0.1% to 0.25%
 - Accuracy Detail 0.25% linearity, hysteresis and repeatability combined
 - Burst Pressure Note 300% of rated pressure
 - Compensated Temperature, Max 71 °C
 - Compensated Temperature, Min 16 °C
 - Electrical Output 3 mV/V
 - Electrical Output Note 3 mV/V nominal
 - Input Resistance 350 Ω
 - Materials, Wetted 17-4 Stainless Steel
 - Operating Temperature, Max 149 °C
 - Operating Temperature, Min -73 °C
 - Output Resistance 315 Ω to 530 Ω
 - Supply Power Note 10 Vdc (15 V maximum)
 - Supply Voltage 10 Vdc
 - Thermal Effect on Span error, Max 0.0054% rdg/°C
 - Thermal Effect on Zero error, Max 0.0054% rdg/°C, 0.008% FSO/°C
 - Zero/Balance Error ± 2.0% FSO
 
OMEGA’s PX35 is a high-accuracy, millivolt output, industrial pressure transducer. It can be ordered with a hermetically sealed gauge, making it suitable for the harshest environments. The PX35 is available in gauge, sealed gauge, and absolute models. Three meters (10') of 4-conductor shielded cable is standard. A twist-lock-connector electrical termination is also available.
Show Ratings & Reviews
 
			
	
	
	
How is the accuracy of this transducer stated? it says 0.25%...Is that % of reading,% of full scale or is it linearity for best fit straight line? I am pairing this with a DP25B panel meter and am trying to ascertain the total system accuracy spec.Thanks
            Thanks for reaching out to Omega. The accuracy for this product is 0.25% linearity, hysteresis, and repeatability combined. If you have any further questions, please do not hesitate to call our Tech Support team.
            
            
    Date published: 2022-08-19
        Is 5VDC enough to operate this sensor?
            Thank you for your inquire.
The specs state
Excitation: 10 Vdc (15 V maximum)
You may try to use at 5 but can not guaranty that the accuracy will hold.
You will also get half the output.
            
            
    Date published: 2022-09-01