Product Overview
  • Genauigkeitsklasse 0,1 % bis 0,25
  • Zusätzliche Merkmale 1 Keiner
  • Bandbreite DC bis 1 kHz
  • Gehäusematerial 316 Edelstahl
  • Gehäuse-Nennwerte IP65
  • Isolationswiderstand 1 MΩ bei 25 Vdc
  • Druckzyklen 10 Millionen, mindestens
  • Druck, min. 0 psi
  • Druck Hinweis Drucküberlast: -15 bis 50 psig und 0 bis 1000 psia: 3-facher Nenndruck oder 20 psi, je nachdem, welcher Wert größer ist, 100 bis 10.000 psig: 2-facher Nenndruck
  • Prozessanschlussgröße 1/4 zoll
  • Prozessanschlusstyp NPT-Außengewinde
  • Reaktionszeit <1 ms
  • Serien-ID PX309
  • Schock 50 g, 11 ms Halbwelle (Halbsinus)
  • Shunt-Kalibrierungswert In vertikaler Richtung mit nach unten gerichteter Montage sind die Kombinationsbereiche nur für positiven Druckausgang kalibriert.
  • Stabilität ± 0,25 %
  • Hinweis zur Stabilität 1-Jahres-Stabilität: <0,25 % FS
  • Versorgungsspannung 9 bis 30 VDC
  • Vibration ± 20 g
  • Gewicht 154 g
Die Edelstahl-Druckaufnehmer der Serie PX309 von OMEGA unter 100 psi verwenden einen hochgenauen Siliziumsensor, der durch eine ölgefüllte Edelstahlmembran geschützt ist. Geräte ab 100 psi verwenden molekular gebundene Silizium-Dehnungsmessstreifen auf der Edelstahlmembran.

Wir bieten ein vollständiges Leistungsspektrum – von der Produktentwicklung über Design und Prototypen bis hin zur Fertigung und Prüfung. Unsere Anwendungstechniker arbeiten eng mit unseren Kunden zusammen, um Produkte zu individualisieren, zu entwerfen oder komplett neu zu entwickeln. Rufen Sie uns an – ganz gleich, ob Sie OEM, Hersteller oder Endanwender sind.

Link zum Artikel über die Installation von Druckaufnehmern

Der PX309 ist auch in metrischen Ausführungen erhältlich; bitte beachten Sie den PXM309 für vollständige Details oder kontaktieren Sie unsere Druckabteilung für weitere Informationen.

Gemeinsame Spezifikationen
Bereiche: -15 bis 50 psig, 0 bis 1000 psia, 100 bis 10.000 psig
Genauigkeit (Kombinierte Linearität, Hysterese und Wiederholbarkeit): ± 0,25 % BSL, max.
Minimaler Widerstand zwischen Gehäuse des Aufnehmers und jedem Draht: 1 MΩ @ 25 Vdc
Kalibrierung: Vertikal mit Anschluss nach unten, nur positive Ausgänge
Druckzyklen: Mindestens 10 Millionen
Drucküberlast: -15 bis 50 psig und 0 bis 1000 psia: 3-facher Nenn-Druck oder 20 psi, je nachdem, welcher Wert höher ist; 100 bis 10.000 psig: 2-facher Nenn-Druck
Berstdruck: -15 bis 50 psig und 0 bis 1000 psia: 4-facher Nenn-Druck oder 25 psi, je nachdem, welcher Wert höher ist; 100 bis 10.000 psig: 5-facher Nenn-Druck
Langzeitstabilität (1 Jahr): ± 0,25 % FS, typisch
Betriebstemperatur: -40 bis 85 °C (-40 bis 185 °F)
Druckanschluss: ¼-18 MNPT
Material des Druckanschlusses: -15 bis 50 psig und 0 bis 1000 psia: 316 SS; 100 bis 10.000 psig: SS 316 oder 17-4
0 bis 500 psi: kann HNBR-O-Ring in der benetzten Druckanschlussbaugruppe enthalten
Bandbreite: DC bis 1 kHz (typisch)
CE: Konform
Stoßfestigkeit: 50 g, 11 ms Halbwelle
Vibration: ± 20 g
Ansprechzeit: <1 Millisekunde
Gewicht:
PX309: 154 g (5,4 oz)
PX319/329/359: 100 g (3,5 oz)
IP-Schutzart: IP65

BITTE BEACHTEN SIE DIE 'SPECS' FÜR WEITERE SPEZIFIKATIONEN FÜR JEDEN AUSGANG (mV, 0 bis 5 Vdc und 4 bis 20 mA)

Accessories

accessories

Environmentally protected connector with 6 female contacts, -55 to 125 °C (-67 to 257 °F) temperature range
€ 48,23 / each
0 In Stock
Compact Analog Current or Voltage to IO Link Convertor
€ 185,81 / each
0 In Stock

cables

2 m (6 ft) vented cable with M12 connector for PX359 for gage ranges &lt;500 psi
€ 119,05 / each
0 In Stock
5 m (16 ft) vented cable with M12 connector for PX359 for gage ranges &lt;500 psi
€ 166,26 / each
0 In Stock
4 Contacts
€ 40,84 / each
0 In Stock
DC Cable Assemblies for Probes, Sensors and Transmitters
€ 28,04 / each
0 In Stock

meters/controllers

1/8 DIN Thermocouple and RTD Panel Meter with Large, Selectable Color Display
€ 491,22 / each
0 In Stock
1/8 DIN Thermocouple and RTD Panel Meter with Large, Selectable Color Display
€ 491,22 / each
0 In Stock
PLATINUM™ Series Digital Panel Meters
€ 381,83 / each
0 In Stock
Rated 1 out of 5 by from Untrustworthy calibrations Faked calibration certificate (again). Claims to have been calibrated to 10,000psi using calibration equipment that will go to only 6,000psi
Date published: 2024-04-13
Rated 2 out of 5 by from Word of Caution The product performance was great, but there is a major design flaw. The cable connection option has the cable connected to the body by a nut that if loosened and taken off will break the unit. Whereas the PX409 series differential transducer instead does not have this problem, it has a sealed connection that doesn't allow you to break the unit so easily. The reason I was attempting to take the nut off in the first place was because it was loose and the unit was dunked under water for cleaning so I was trying to make sure the unit would dry out fully before supplying power to the transducer.
Date published: 2021-04-16
Rated 4 out of 5 by from compact and reliable Have purchased several of these transducers over the last 10 years and do not recall ever having to replace one due to failure. I usually get the 319 series and my only complaint is that there is no key on the connector to simplify pin alignment. They are also offered a wide range of pressure ratings.
Date published: 2019-04-04
Rated 5 out of 5 by from transducer excellent product and work great. this was ordered as a replacement for an o
Date published: 2026-10-05
Rated 5 out of 5 by from Durable Reporting Used on our propeller dyno testing , durable and dependable in a harsh environment
Date published: 2026-09-22
Rated 5 out of 5 by from Performance Good quality pressure sensor. Accurate readings, easy installation, and reliable performance.
Date published: 2026-09-06
Rated 5 out of 5 by from Quality The pressure sensor appears to be well made and performs reliably. The readings are accurate and stable, and installation was straightforward. Overall, a good product for the intended application.
Date published: 2026-09-06
Rated 5 out of 5 by from Delivery Great pressure sensor. It works as expected, is accurate, and was easy to install. Good quality for the price.
Date published: 2026-09-06
  • y_2026, m_11, d_4, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_78
  • loc_en_CA, sid_PX309-001A10V, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT

Where can I find the transfer function for a PX309-100A10V? Is it included in the calibration documentation or do I have to generate it myself?

Asked by: dtorgersen
I am reading voltages off the sensor and using custom software to output a pressure. where do i find the equation that converts the sensor output voltage to pressure?
Answered by: dtorgersen
Date published: 2024-11-04

Is there a manual for installing and programming the PX309-5KG5V? I tried accessing the ftp.omega.com site, but it wasn't working. There also isn't a user manual on the product site. I am trying to connect it to a Arduino Uno and a 12V battery.

Asked by: nbosio1001
The PX309-5KG5V is simply an analog output sensor generating a 0 to 5VDC signal over it's 0 to 5000 PSI pressure range. There is no programming necessary and there is no manual. A wiring is available on both the specification sheet on our website and the calibration report that is shipped with the unit. This is a 3 wire device and wiring is as follows. Red wire should connect to the positive(+) side of our 12V battery. Black wire should connected to both the negative (-) side of your 12V battery and the negative (-) or low input of your readout device. White wire should connect to the positive (+) or high input of your readout device. We would have not have any info on how specifically you would connect this to a Arduino Uno
Answered by: Applicatrions Engineer JK
Date published: 2022-11-04

What is the maximum load that can be used in series with the PX309-1KA (4-20mA output)?

Asked by: ExampleName
Thank you for your inquire. over pressure 0 to 1000 psia: 3 times rated Burst Pressure 0 to 1000 psia: 4 times rated pressure
Answered by: application engineer je
Date published: 2022-06-14

I have the PX359-015A10V pressure transducer (0-15 psia, 0-10V output). I am wondering if the 0.25% accuracy, that is given on the specification sheet, means that the accuracy is 0.25% of the full scale?

Asked by: JoeyH9
Yes the 0.25% accuracy is of the full scale range of the sensor.
Answered by: Applicatrions Engineer JK
Date published: 2020-11-23

Can it be exposed to vacuum? I'm going to measure the positive pressure inside a sealed box when it's filled with inert gas. But the box will also be pumped to vacuum sometimes (pressure will be measured by other gauges). Will this transducer be damaged?

Asked by: wanglikun08
Yes the PX309 Absolute reference can be used inside a vacuum chamber
Answered by: Applicatrions Engineer JK
Date published: 2019-11-20

Does Omega PX309 read above the +15 PSI maximum pressure with less accuracy or the15 PSI is the maximum positive pressure that can read? and what will happen if my sample produces more pressure than the specified limit, is that going to damage the sensor?

Asked by: ZARA
Thank you for your inquiry, the PX309 15PSI has a Pressure Overload rating of 3 times rated pressure. The accuracy of the unit is based on zero to full scale, we do not guarantee specifications over the rated pressure.
Answered by: rkent
Date published: 2022-09-09

Are there any limitations for using the PX309 series transmitters under constant exposure to hydrogen gas (pressures up to 3k psi)? (hydrogen embrittlement specifically) Thank you.

Asked by: alphaTech
The PX309 should not be used to measure hydrogen. Embrittlement will occur.
Answered by: Applicatrions Engineer JK
Date published: 2020-10-09

How do I know if my PX359-500A5V contains HNBR o-ring in the wetted pressure port assembly?

Asked by: Myke
We have several suppliers for the 0 to 500 psi sensing element used in the PX309 Series pressure transducer. One of them inadvertently supplied elements with the HNBR O-ring. Unfortunately there no way to identify which units were built use this element without physically cutting unit open the unit which would basically destroy it.
Answered by: JK Applications Eng
Date published: 2024-07-11
  • y_2026, m_11, d_4, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_49
  • loc_en_CA, sid_PX309-001A10V, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
PX301259-001A005A015A030A050A100A200A300A500A1KA001G002G005G015G030G050G100G150G200G300G500G1KG2KG3KG5KG7.5KG10KG015V015CGV030GV050GV100GV150GV5V10VI
Electrical Connection
Pressure Range & Type
Output Type
en-CA
en_CA
Save Configuration