Need assistance? Call us: 1-800-663-4209
KW350
Power Meter
- Cost-effective energy monitoring: KW350 meters provide 3-channel power and energy measurement for sub-metering panels, equipment load monitoring, and energy management systems.
- Revenue-grade accuracy: 0.5 class accuracy supports dependable measurement of active energy, reactive energy, apparent energy, voltage, current, power, demand, power factor, and frequency.
- Flexible system compatibility: Supports single-phase, 3-phase 4-wire WYE, and 3-phase 3-wire Delta service types for a wide range of electrical applications.
- CT input options: Available for either 333 mV current transformers or Rogowski coil inputs, allowing the meter to fit retrofit and new-installation requirements.
- Built-in display and setup: LCD display with important-parameter, all-parameter, and settings modes makes local setup and readings straightforward.
- Serial communication ready: User-selectable RS-485 Modbus RTU or BACnet MS/TP communication enables integration with BAS, data acquisition, and energy monitoring platforms.
- Smart diagnostics and alarms: Auto phase-check helps identify common wiring mistakes, while the built-in relay can trigger alarms for key meter events.
- Installation-friendly design: Standard IEC 35 mm DIN rail mounting plus optional NEMA 4X prewired panel upgrades simplify deployment in electrical cabinets and retrofit projects.
- Ideal for efficiency projects: Well suited for renewable energy, predicted maintenance, overhead cost reduction, LEED, green buildings, NET ZERO initiatives, and refrigeration monitoring.
- Certified and secure: BTL Certified, CE, UKCA, RoHS2, and cULus Listed, with password-protected settings and a sealed tamper-proof cover.
Product Overview
- Accuracy 0.5 Class
- Applications Building and Maintenance, Control Panel, Environmental Monitoring, Industrial and Manufacturing
- Approvals BTL Certified, CE, UKCA, RoHS2, cULus Listed (File # E359521), Glow Wire Test (IEC 695-2-1) 960 °C, Halogen free (DIN/VDE 0472, Part 815)
- Connection Note DIN rail mounted pre-labeled terminal blocks for voltage and CT connections pre-installed
- Data Format 8 data bits:no parity:1 stop bit
- Display Type LCD
- Enclosure Material Flame retardant polycarbonate
- Enclosure Ratings IP67, UL Type 12, UL Type 13, UL Type 4, UL Type 4X, UL Type 6, UL Type 6p
- Frequency 50/60 Hz
- Fuse Rating 600 VAC/2A
- Height 7.01 in
- Input_Current Note 150% of current sensor rating (mV CT’s) to maintain accuracy. Up to 6000 Amps w/ Rogowski Coils
- Insulation Note Electrical Insulation: Totally Insulated
- Isolation 2000 Vac
- Length 11.81 in
- Load Current, Max 5 A
- Load Voltage, Max 30 V
- Measurement Type Single Phase, 3 Phase – Four Wire (WYE), 3 Phase – Three Wire (Delta)
- Mounting IEC 35mm DIN Rail (Standard)
- Network and Communications BACnet Device Instance Number: 1 (Default); Field adjustable from 1 to 4194303; ; Max Station: 127 MS/TP Masters (MAC Addresses is 0 to 127)
- Number of Channels Note Voltage Channels: 400 Volts AC (L-N), 690 VAC (L-L), 50/60 Hz
- Number of Inputs 3
- Operating Distance, Max 1200 m
- Operating Humidity 5 to 95% RH, non-condensing
- Operating Temperature, Max 158 °F
- Operating Temperature, Min -13 °F
- Output Detail Pulse Output: Two-wire pulse train, Isolation Voltage 2500 VAC, 5~60 VDC Load Voltage, 10 mA Max Load Current, Pulse Width 20~100ms, Pulse Constant 1~60,000
- Relay Output 250 Vac
- Sampling Rate 3.84kHz @ 60 Hz; 3.2kHz @ 50 Hz
- Security Password Protected to access Settings. Sealed and Tamper Proof Cover.
- Series ID KW350
- Software AcuRev 1310 Utility Software, Windows Based; (USB-RS485 converter is required to connect to computer)
- Storage Temperature, Max 185 °F
- Storage Temperature, Min -40 °F
- Supply Power Note Energy Pulse Power Supply: External 24 VDC Power Supply (Required) Note: 1K Ohm External Current Limiting Resistor (Recommended)
- Supply Voltage 100 to 415 Vac, 100 to 300 Vdc
- Termination 120 to 300 Ω
- Update Rate Accumulated Parameter Update Rate: 1 sec ; Real Time Parameter Update Rate: 200 ms
- Voltage Measurement Range 100 to 400 Vac (L-N), 100 to 690 Vac (L-L)
- Weight 3.8 lb
- Width 11.81 in
- Wire Gauge 22 to 14 AWG
Supported Applications
The ACI KW350 is a digital power meter designed for monitoring electrical power parameters in industrial and commercial applications. It provides real-time, True RMS measurement of instantaneous voltage, current, power, frequency, and power factor. The series supports revenue-grade accuracy suitable for billing or energy auditing purposes.
- Single Phase service
- 3-Phase – Four Wire (WYE) configurations
- Three Phase – Three Wire (Delta) configurations
Operating Conditions & Performance
The KW350 operates within an ambient temperature range of -13 to 158°F (-25 to 70°C) and a storage temperature range of -40 to 185°F (-40 to 85°C). Humidity ratings are specified as 5 to 95%, non-condensing. The meter achieves IEC 62053-22 0.5s Class / ANSI C12.20 0.5 Class accuracy for Active, Reactive, and Apparent Energy; Voltage; Current; Power parameters; Power Factor; and Demand measurements. Frequency measurement accuracy is rated at 0.2%.
- Real Time Parameter Update Rate: 200 mS
- Accumulated Parameter Update Rate: 1 Sec
- Meter Sampling Rate: 3.84kHz @ 60 Hz; 3.2kHz @ 50 Hz
- Ingress Protection (EN 60529): IP67
- NEMA Rating: UL Type 4, 4X, 6, 6P, 12 and 13
Configuration Options
The series is configurable for different current sensing technologies and mounting requirements. Standard models feature IEC 35mm DIN Rail mounting with a polycarbonate housing (UL 94V-0). A panel upgrade option installs the meter in a NEMA 4X enclosure.
- Current Inputs: Supports 3 channels, accepting either 333 mV CTs or Rogowski Coils (up to 6000 Amps with Rogowski Coils).
- Voltage Channels: Rated for 100-400VAC Line to Neutral (L-N) or 100-690VAC Line to Line (L-L), and 50/60 Hz.
- Power Supply: Requires an external 24 VDC power supply. A 1K Ohm External Current Limiting Resistor is recommended for the energy pulse output circuit.
- Communication Protocols: Serial RS-485 Modbus RTU (SunSpec IEEE-754 Single Precision Floating Point Format) or BACnet MS/TP with a maximum distance of 1200 meters at data rates up to 100K bits/second.
- Outputs: Includes an energy pulse output (Two-wire, Isolation Voltage 2500 VAC, Pulse Constant 1-60,000) and a built-in relay for alarm triggering (Load Voltage: 250VAC, 30VDC; Max Load Current: 5A).
- Display: Built-in LCD with three display modes (Important Parameters, All Parameters, Settings Display Modes).
Key Product Differences
The KW350 series distinguishes models based on current sensor type and enclosure configuration. The standard model number guide follows the format KW350-P1-D-S--.
- Rogowski Coil Input: Models ending in "RC" (e.g., KW350-P1-D-S-RC) are configured for Rogowski coil inputs.
- Standard CT Input: Models ending in "SC" (e.g., KW350-P1-D-S-SC) accept 333mV current transformer inputs.
- Panel Upgrade: Models with the "PC" suffix (e.g., KW350-P1-D-S-RC-PC, KW350-P1-D-S-SC-PC) include a NEMA 4X enclosure installation with labeled and prewired supply voltage and CT connections.
- Accessories: The series supports optional accessories including the KW350-ENC (NEMA 4X/IP66 Wall Mount Enclosure), USB-RS485 converter, and AK-03 Three Fuse Pack.