Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

RDXL-SD-Series

Portable Thermometer Thermocouple Data Loggers with SD Card

Models In Stock
  • SD Card, Real-Time Data Logger
  • Input Signals: T/C K, J, T, E, R/S, and RTD Pt100 Ω Measurement (RDXL4SD Only)
  • Display All Input Channels Simultaneously
  • Data Hold, Record Max and Min Reading
RDXL-SD-Series
From C$ 706.21
Models In Stock
Portable Thermometer Thermocouple Data Loggers with SD Card RDXL-SD-Series RDXL-SD-Series
loading all models
Product Overview
  • Data Interface USB, RS232
  • Data Interface Note RS232/USB PC computer interface
  • Display Note Display Sampling Time : Approx 1 second
  • Display Size 102 mm (4 in)
  • Height 177 mm
  • Length 45 mm
  • Power Consumption 30 mA
  • Sampling Time 1 to 3600 sec
  • Series ID RDXL-SD-Series
  • Storable Readings Maximum, Minimum
  • Storage Capacity SD Card upto 16 GB
  • Supply Voltage 1.5 Vdc
  • Temperature Resolution 0.1 °C
  • Temperature Sensor Type Thermocouple
  • Temperature Sensor Type Note Type J, K, T, E, R/S thermocouple probe Pt100 Ω (european curve) for RDXL4SD model only
  • Weight 489 g
  • Width 68 mm

Supported Applications

The Omega RDXL-SD Series comprises portable, multi-channel thermometer data loggers designed for real-time temperature measurement and recording. The series includes the RDXL4SD (4-channel) and RDXL12SD (12-channel) models, which support Type K, J, T, E, R, and S thermocouples as well as Pt 100 Ω RTD sensors. These handheld devices feature an LCD display with green backlighting for simultaneous channel monitoring and utilize SD memory cards ranging from 1 GB to 16 GB for data storage.

Operating Conditions & Performance

The RDXL-SD Series operates within an ambient temperature range of 0 to 50°C (32 to 122°F) and a relative humidity limit of less than 85% RH. Measurement performance varies by sensor type, resolution setting, and specific temperature span. The series supports automatic temperature compensation for Type K/J/T/E/R/S thermocouples and linear compensation across the full range.

Sensor Ranges and Accuracy:

  • Type K (Thermocouple): Measures from -50.1 to 1300°C. At 0.1°C resolution, accuracy is ±(0.4% + 1°C) for the -50.1 to -100.0°C span and ±(0.4% + 0.5°C) for the -50.0 to 999.9°C span; at 1°C resolution (1000 to 1300°C), accuracy is ±(0.4% + 1°C).
  • Type J, T, E: Support ranges up to 1200°C, 900°C, and 900°C respectively (per manual), with accuracy specifications of ±(0.4% + 1°C) or ±(0.4% + 0.5°C) depending on the temperature band.
  • Type R/S: Measure from 0 to 1700°C (Type R) and 0 to 1500°C (Type S). Accuracy is specified as ±(0.5% + 1°C).
  • Pt 100 Ω RTD: Available on the RDXL4SD model only, measuring from -199.9 to 850°C. Accuracy is ±(0.4% + 1°C) at 0.1°C resolution.
  • Fahrenheit Scales: Corresponding ranges and accuracies are provided in °F, such as Type K from -58.1 to 2372°F.

Note: Accuracy values apply to the meter only when tested under an environment temperature of 23 ±5°C. The display sampling time is approximately 1 second, and data logging intervals are configurable from 1 second to 3600 seconds.

Configuration Options

The series offers distinct channel configurations, sensor compatibility options, and connectivity features tailored for portable field use or stationary monitoring with battery power.

  • Channel Configurations:
    • RDXL4SD: 4-channel digital thermometer; includes support for two input channels when using RTD sensors. Ships complete with four beaded wire Type K thermocouple probes.
    • RDXL12SD: 12-channel thermometer; ships complete with twelve beaded wire Type K thermocouple probes.
  • Memory and Data Logging:
    • Supports SD memory cards from 1 GB to 16 GB.
    • Sampling modes include Auto (settable time) and Manual (push-button save).
    • Data can be downloaded via RS232 or USB PC interface for analysis in Excel.
  • Power Supply:
    • RDXL4SD: Powered by six AA alkaline batteries (UM3) or an optional DC 9V adapter input.
    • RDXL12SD: Powered by eight AA alkaline batteries (UM3).
    • Features auto power-off management to conserve battery life.
  • Physical Interface:
    • LCD display size of 52 mm x 38 mm.
    • RDXL4SD dimensions: 177 H x 68 W x 45 mm D (7 x 2.7 x 1.9"); weight is 489 g (1.08 lb).
    • Input sockets include a 2-pin thermocouple socket for Type K/J/T/E/R/S and an earphone-style socket for Pt 100 Ω RTD.

Key Product Differences

The primary distinction between the two models in this series is channel capacity and included accessories:

  • RDXL4SD vs. RDXL12SD Channel Count: The RDXL4SD provides four measurement channels, while the RDXL12SD expands this to twelve.
  • RTD Support: Pt 100 Ω RTD input is available only on the RDXL4SD model (limited to two input channels for RTDs). The RDXL12SD supports thermocouples but does not list RTD capability in its primary specification table.
  • Included Probes: Each unit ships with a specific quantity of beaded wire Type K probes matching the channel count (4 or 12).
  • Casing and Accessories:
    • RDXL4SD includes a soft carrying case.
    • RDXL12SD includes a hard carrying case.
    • Both models include a 2 GB SD memory card, batteries, and operator's manual. Optional accessories such as the RDXLSD-CONN (RTD connector), data logging software (SW-U101-WIN for RDXL4SD; SW-U811-WIN for RDXL12SD), AC adapters, spare cables, and hard cases are available separately.

Accessories

accessories

HARD CASE
C$90.26 / each
5 In Stock
SOFT CASE
C$43.26 / each
7 In Stock
SW FOR RDXL12SD ONLY
C$313.62 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.

cables

RS232 CABLE
C$56.15 / each
0 In Stock
This item is discontinued. Please contact Technical Sales Team for assistance.
USB CABLE
C$176.07 / each
11 In Stock
Rated 5 out of 5 by from Easy to use, intuitive interface. Used this device to collect a days worth of thermal / temperature data, worked really well.
Date published: 2016-02-01
Rated 5 out of 5 by from Great Data logger Got two of these for temperature profiling of our freezers, very convenient to set up and use these. This model did not have an AC adapter - which could be handy especially for long term data recording (or redundancy) to prevent data loss due to battery draining out. Otherwise, this is a great unit for portability and convenience.
Date published: 2018-07-05
Rated 5 out of 5 by from Reliable product! Good customer service! Ordering was straightforward, arrived quickly and works as intended!
Date published: 2026-07-10
Rated 5 out of 5 by from Great Item Just as described works great easy to read and nice big buttons
Date published: 2026-02-18
Rated 3 out of 5 by from Fair to middling Instructions were vague at best, took three trial runs to finally figure out the unit.
Date published: 2025-09-24
Rated 5 out of 5 by from 10/10 Fantastic product and fantastic customer service. I had a few questions about billing and invoicing that were answered quickly and comprehensively.
Date published: 2024-12-02
Rated 5 out of 5 by from Very versatile temp data logger Very versatile temp data logger that can handle different types of thermocouple. Can sample at various times and log onto an SD card and easily be viewed in a spreadsheet.
Date published: 2023-08-21
Rated 4 out of 5 by from Nice data logger, easy to use Purchased for manufacturing operations. Works great and easy to use. It has a 3 week leadtime but on time to commitment.
Date published: 2017-08-22
  • y_2026, m_8, d_5, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_CA, sid_RDXL12SD, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT

Where can I get a 9V power supply for this unit? I got the unit hot and now the battery compartment is warped.

Asked by: Marty
The external power supply for the meter is ADAPTER-SD.
Answered by: Temperature
Date published: 2020-04-09

Good morning, Devise: RDXL 12SD Is it possible to apply a different Offset on the 12 channels? What method? * Type K and J thermocouple

Asked by: Dany D
The offset entered on the RDXL12SD will be for all channels not individually.
Answered by: ApplicationEngineerANB
Date published: 2024-04-26

Can this model display max/min for ALL 4 channels simultaneously?

Asked by: Donovan
Yes, the meter will display all four channels.
Answered by: Temperature
Date published: 2019-11-07

I need thermocouples that can be exposed to direct flame. Which ones would be compatible to this device?

Asked by: casscole17
Thank you for your inquiry! You can use bare thermocouple wire rated for the appropriate temperature range to directly measure the temperature of a flame. However, if you plan to measure for an extended duration of time, it would be best to select a thermocouple probe for durability and repeatability of your measurements. Lastly, the thermocouple you choose should have a mini connector to connect into this data logger.
Answered by: Application Engineer CK
Date published: 2021-05-31

Besides the Temperature Offset, can this unit be calibrated. For example can the A/D converter be calibrated with a precise mV source. If not, what is done when buying with a NIST traceable certificate "-CAL"

Asked by: ChrisS
The Logger can be returned for a NIST calibration but the procedure is proprietary and not available to send out.
Answered by: ApplicationEngineerANB
Date published: 2022-05-10

I need to record in liquid nitrogen (-320) do you have any recommendations on probes or if this can record temperatures that low.

Asked by: Cyle33
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:00PM EST).
Answered by: Application Engineer CB
Date published: 2024-11-28

Will the data still be logged after starting the REC and then powering off the unit? Or does the display need to stay on for the logging to occur?

Asked by: MPalma
The Logger should be left on when in record mode. When in record mode the meter enters into a low power consumption operation until recording is terminated.
Answered by: ApplicationEngineerANB
Date published: 2024-08-02

RDXL 12 SD do you have a calibration manual???

Asked by: Laerie
Thank you for your inquiry. We believe the best assistance would come from speaking to us directly at 888-826-6342 ask for the Temperature Department Mon. – Fri. (HOURS 8:30AM - 5:30PM EST).
Answered by: Application Engineer CB
Date published: 2024-04-11
  • y_2026, m_8, d_5, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_10
  • loc_en_CA, sid_RDXL12SD, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 12ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration