Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

DPPT-Series

PLATINUM™ Series Universal Input Digital Panel Meters

Models In Stock
  • Strain &  Bridge Inputs, 6 Digit Display and Upgraded Platinum Software Now Available
  • Super High Performance (20 Samples / Sec), High Accuracy
  • Extremely Versatile yet Easy and Intuitive to Use
  • Bright 3-Color (RED, GREEN, and AMBER) 9 Segment LED Display with Wide Viewing Angle
While this item has an extended lead time, our 16B , 32B , DP20 , DP400S and DPS20 series offer similar specs and shorter wait times.
DPPT-Series
From C$ 391.68
Models In Stock
PLATINUM™ Series Universal Input Digital Panel Meters DPPT-Series DPPT-Series
loading all models
Product Overview
  • A/D Conversion 24-bit sigma delta
  • Accuracy 0.03 % FS
  • Additional Features 1 Programmable 3 Color Display
  • Approvals UL, cUL, CE, UKCA
  • CMRR 120 dB
  • Configuration Differential
  • Cutout Dimensions 45 mm
  • Data Interface Note Ethernet Standards Compliance: IEEE 802.3 10/100 Base-T auto-switching, TCP/IP, ARP, HTTPGET Protocols: OMEGA ASCII, MODBUS® ASCII/RTU
  • Display Range -1999 to 9999
  • External Fuse Required Time-Delay, UL 248-14 Listed: 100 mA/250 V; 400 mA/250 V (low voltage option) ;Time-Lag, IEC 127-3 Recognized: 100 mA/250 V; 400 mA/250 V (low voltage option)
  • Frequency 50 to 400 Hz
  • Height 48 mm
  • Impedance Input Process/Strain: 10M Ω for ±100 mV, 1M Ω for other voltage ranges ;Process Current: 5 Ω ;Thermocouple: 10K Ω max
  • Input Current 4 to 20 mA, 0 to 24 mA
  • Input Type Thermocouple, RTD, Thermistor, Current, Voltage, Strain
  • Input Voltage -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
  • Isolation Power to Input/Output: 2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option) Power to Relays/SSR Outputs: 2300 Vac per 1 min test Relays/SSR to Relay/SSR Outputs: 2300 Vac per 1 min test RS232/RS485 to Inputs/Outputs: 500 Vac per 1 min test
  • Length 127 mm
  • Measuring Range Process Voltage: ±50 mV, ±100 mV, ±1, ±10 Vdc;Process Current: Scalable within 0 to 24 mA;Thermocouple;Type J: -210 to 1200 °C ;Type K: -270 to 160 °C and -160 to 1372 °C;Type T: -270 to -190 °C and -190 to 400 °C;Type E: -270 to -220 °C and -220 to 1000 °C;Type R: -50 to 40 °C and 40 to 1788 °C;Type S: -50 to 100 °C and 100 to 1768 °C;Type B: 100 to 640 °C and 640 to 1820 °C;Type C: 0 to 2320 °C;Type N: -250 to -100 °C and -100 to 1300 °C;RTD;Pt, 0.00385, 100 Ω, 500 Ω, 1000 Ω: -200 to 850 °C;Pt, 0.003916, 100 Ω: -200 to 660 °C;Pt, 0.00392, 100 Ω : -200 to 660 °C;Thermistor;2252 Ω: -40 to 120 °C;5K Ω: -30 to 140 °C;10K Ω: -20 to 150 °C
  • Number of Inputs 1
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Operating Temperature Note 0 to 50°C (32 to 122°F), 90% RH non-condensing
  • Polarity Bipolar
  • Power Consumption 4 W
  • Reading Rate 20/sec
  • Relative Humidity 0.9
  • Resolution 0.1° temperature; 10 µV process
  • RTD Input Range 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100 Ω only), or 0.003916 (100 Ω only) curves
  • Sampling Rate 20 Hz (20 updates/second)
  • Sensor/Transmitter Power 5, 10, 12 and 24 Vdc @ 25 mA
  • Sensor/Transmitter Power Note Firmware selectable (no jumpers to set) to 5, 10, 12, and 24 Vdc @ 25 mA
  • Series ID DPPT-Series
  • Strain Input ± 50 mV, ± 100 mV
  • Supply Power Note 90 to 240 Vac ±10%, 50 to 400 Hz*, 110 to 375 Vdc, equivalent voltage
  • Temperature Stability RTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C
  • Thermistor Input Range 2252 Ω, 5K Ω, 10K Ω
  • Thermocouple Type J, K, T, E, R, S, B, C, N
  • Warm Up Time 30 mins
  • Width 48 mm

Supported Applications

The DPPT Series is the OMEGA PLATINUM™ family of microprocessor-based universal-input digital panel meters, built for high-accuracy temperature and process indication in industrial control panels. A bright 3-color (red, green, amber) 9-segment LED display with a wide viewing angle makes readings easy to see across a control room, machine console, or process skid.

Because each meter accepts thermocouples, RTDs, thermistors, and process voltage or current signals, the DPPT Series covers a wide span of monitoring and control tasks — from furnace and oven temperature to flow, pressure, and load signals delivered by process transmitters and strain sensors. Flexible alarm programming, isolated analog retransmission, and optional serial and Ethernet communications extend the series into alarming, control, and networked data acquisition roles.

Operating Conditions & Performance

DPPT meters run from a universal supply of 90 to 240 Vac ±10%, 50 to 400 Hz, or 110 to 375 Vdc, with a low-voltage option of 12 to 36 Vdc. A 24-bit sigma-delta converter samples at 20 readings per second and resolves temperature to 0.1°, while process inputs resolve to the 10 microvolt level.

The universal input handles wide, sensor-specific ranges: a J thermocouple spans -210 to 1200°C (-346 to 2192°F), a K thermocouple reaches -160 to 1372°C (-256 to 2502°F), and thermocouple accuracy is as tight as 0.4°C (0.7°F). RTD inputs cover 100 Ω, 500 Ω, and 1000 Ω platinum sensors with accuracy to 0.3°C, and process inputs read voltage to ±100 mV and ±10 Vdc or current across 0 to 24 mA at 0.03% FS.

The meters operate over an ambient range of 0 to 50°C (32 to 122°F) at 90% RH non-condensing. The 1/32 and 1/16 DIN models carry a NEMA 4X (IP65) front bezel for wash-down panel faces, while the 1/8 DIN models use a NEMA 1 front bezel. All sizes share a common 127 mm case depth.

Configuration Options

The DPPT Series is configured through a structured model number, DP<Size>Pt - <Alarm Outputs> - <Communications> - <Power>, so a meter can be tailored to the panel, the alarm scheme, the network, and the available power:

  • DIN size — 1/32, 1/16, and 1/8 DIN formats fit the available cutout. The 1/32 and 1/16 DIN models drive a 10.2 mm digit height, while the larger DP8Pt/DP8EPT display uses a 21 mm digit height.
  • Alarm outputs — the -330 option adds two mechanical relays for alarm and control; SPDT and SPST relays are rated 250 Vac or 30 Vdc at 3 A, alongside an SSR rated 20 to 265 Vac.
  • Communications — USB is standard on every model; the -C24 option adds software-selectable RS232/RS485 serial, and Ethernet-equipped models carry the -EIP suffix. Ethernet options are not available on 1/32 DIN models.
  • Power — the -DC suffix selects the low-voltage DC power input in place of the standard universal AC supply.

Key Product Differences

The lineup is built from three DIN-size platforms, each expandable with alarm, communications, and power options:

  • DP32Pt — 1/32 DIN universal-input meter (for example DP32Pt-C24 with serial, or DP32Pt-330-C24-DC with two relays, serial, and DC power).
  • DP16Pt — 1/16 DIN universal-input meter, offered with relays, serial, Ethernet, and DC options (for example DP16Pt-330-DC and Ethernet-capable DP16Pt-EIP).
  • DP8Pt and DP8EPT — 1/8 DIN universal-input meters with the larger LED display and the full range of alarm, communications, and power options.

Across the family, thermocouple, RTD, thermistor, and process inputs are common to every size, so a configuration differs only in cutout, alarm and communication options, and power input rather than in core measurement capability.

Accessories

cables

PT SERIES USB ADAPTER
C$25.15 / each
16 In Stock

meters/controllers

PLATINUM™ Series Digital Panel Meters
C$883.86 / each
0 In Stock
PLATINUM™ Series Digital Panel Meters
C$848.04 / each
0 In Stock
Rated 4 out of 5 by from Basic DAQ For a basic data acquisition this part works fine. I had to call into omega for help navigating the menu to get the scaling correct for the 4-20mA, 0-1000psi pressure transducer. If all you need to do is acquire and log data from display this part is just fine.
Date published: 2018-05-23
Rated 5 out of 5 by from Gets the job done Needed to connect different pressure transducer types. The set up was a bit confusing (always hate 100+ page manuals) but tech support was able to assist with no problems. All issues were resolved.
Date published: 2018-11-08
Rated 1 out of 5 by from UNHAPPY VERY HARD TO PROGRAM NO BASIC EXAMPLE PROGRAM. PLAN TO SPEND DAYS PROGRAMMING
Date published: 2018-03-08
Rated 5 out of 5 by from SERAIL COMMUNICATION We have a DP8EPT-006 (Serial # M20430706). We want to know if we can get a serial output from this panel.
Date published: 2024-07-22
Rated 5 out of 5 by from Purchasing Agent Works flawlessly and was delivered in a quick manner!
Date published: 2024-05-13
Rated 5 out of 5 by from PLATINUM DIGITAL METERS These digital meters were a perfect match and were received in a timely manner.
Date published: 2023-11-17
Rated 5 out of 5 by from Good product The meter quality is good and installation instruction is clear
Date published: 2023-10-03
Rated 4 out of 5 by from Digital meter Meter was easy to set up. Display of numbers were is to read
Date published: 2023-05-08
  • y_2026, m_8, d_29, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_13
  • loc_en_CA, sid_DP16PT, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Externally exciting a pressure transducer with 24vdc &amp; a 0-10V output, how is this wired with only one output wire from the transducer?

Asked by: Ramon
got it, jumpered the transducer -24v to pin 1
Answered by: Ramon
Date published: 2021-04-01

The Platinum User Guide and manual do not mention factory calibration. Do these units go through a calibration process? If so. is it traceable to NIST? Or do you consider calibration to be something that is done to analog devices only? Thanks.

Asked by: Superior Tech
Thank you for your inquiry. Unit is shipped fully calibrated from factory.
Answered by: Application Engineer JB
Date published: 2021-01-30

I need a temperature gage that will read Liquid Nitrogen temp. -320&deg;F I found this series, PLATINUM&trade; Series Digital Panel Meters, or do you have a self contained temp gage?

Asked by: mikek
Hi mikek, Thank you for the inquiry. We do not offer fixed mount integrated meter probe combination for Liquid N2 application. Best regards OMEGA
Answered by: AENorwalk
Date published: 2020-03-25

Is this device working with strain gauges (i.e. I.E.E. Low Profile Strain Gauge) directly? Is it possible to connect multiple sensors simultanisouly?

Asked by: Term
This device can cbe connected to one strain gauge.
Answered by: Application Engineer CB
Date published: 2025-01-16

does the dp8pt-dc have battery backup

Asked by: sparky2
Thanks for connecting with Omega. Part number DP8PT-DC does not have battery backup. You do not need to reprogram when power is lost. This unit will retain all the configuration parameters in non-volatile memory. Please email our Tech Support rep back if you have any further questions.
Answered by: Jane
Date published: 2024-02-07

The DPT8 lists a low power option allowing the device to be powered by 24VAC (or 12-36V DC) on the data sheet, but it is not clear what model(s) are associated with this option. The models are listed as being either AC or DC powered only.

Asked by: RichardP
Hi Richard, Thanks for the inquiry. Models are available with the low voltage (power) option and this option is indicated with a suffix &quot;-DC&quot;. Please see data sheet for options table; https://assets.omega.com/pdf/process-control-and-monitoring-devices/meters/process-meters/DPPT_Series.pdf
Answered by: NorwalkAE
Date published: 2020-05-15

What is the ethernet settings password? I searched all the manuals for &quot;password&quot; and for &quot;login&quot; and I didn't find the webpage password for ethernet settings.

Asked by: MTen
Hi MTen, Default login password is &quot;12345678&quot; and administrator password is &quot;00000000&quot;. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-01-16

Is the front panel rain-resistant?

Asked by: Vincent30
Hi Vincent30 Thank you for the request. The 1/8 DIN size bezel is rated NEMA1. The 1/32 and 1/16 size are rated NEMA 4X. We do not recommend any of these where there is exposure of the bezel to weather condition. Best regards OME
Answered by: NorwalkAE_RS
Date published: 2022-10-05
  • y_2026, m_8, d_29, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_24
  • loc_en_CA, sid_DP16PT, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 13ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration