RTDCAP-1KA-2-P098-050-T-40

C$393.64 / each

Item# RTDCAP-1KA-2-P098-050-T-40

In Stock

Lead Time (If not in stock): 13 weeks

Product Specs

<< See all Product Models
Brand
Accuracy Class A
Accuracy Detail Class A (± 0.15+.002*
Cable Length 1 m
Current, Max 2 mA
Electrical Connection Stripped Leads
Housing Material Polyimide
Insulation Resistance >50 MΩ @ 50 Vdc
Insulation Resistance Note Greater than 50 Megohms at 50 Vdc. at 25°C (77°F)
Lead Material Nickle Plated Copper
Long Term Stability 0.05°C (0.02% of resistance) per 5 years, -50 to 300°C, 0.25°C per year to 540°C
Nominal Resistance 1000 Ω
Number of Wires 3
Process Temperature, Max 260 °C
Process Temperature, Min -200 °C
Recommended Current 1 mA
Response Time, Water 0.6 sec
Self Heating Effect >15 mW/°C
Sensing Element RTD
Sensor Diameter 0.098 in
Sensor Length 0.5 in
Temperature Sensor Type RTD
Wire Gauge 28 AWG
Country of Origin United States