Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-CP-XTCTemp-Series

X-Series - Multi-Channel Thermocouple Loggers

Models In Stock
  • Multi-channel thermocouple logger (4–16 channels) with fast 4 Hz sampling for precision temperature tracking
  • Supports J, K, T, E, R, S, B, and N thermocouples with cold junction compensation for superior accuracy
  • Configurable channel names and logging intervals simplify setup and streamline data organization
  • Battery or external power options, USB download, and NIST-traceable accuracy for industrial reliability
OM-CP-XTCTemp-Series
From C$ 1 332.69
Models In Stock
X-Series - Multi-Channel Thermocouple Loggers OM-CP-XTCTemp-Series OM-CP-XTCTemp-Series
loading all models
Product Overview
  • Calibration Digital calibration through software
  • Data Interface WiFi
  • Data Interface Note USB-A to micro USB cable (included); 460,800 baud
  • Electrical Connection Screw Terminal
  • Enclosure Aluminium
  • Form factor Benchtop
  • LED Indicators 1 per channel and 2 status LEDs
  • Length 65.6 mm
  • Operating Humidity 0 to 95% RH
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Process Temperature, Max 60 °C
  • Process Temperature, Min -20 °C
  • Real Time Recording May be used with PC to monitor and record data in real time
  • Samples,Max 2000000
  • Sampling Rate 1 day
  • Sampling Rate Note 4 Hz up to 1 reading every 24 hours
  • Series ID OM-CP-XTCTemp-Series
  • Software Compatibility Windows® XP/VISTA/7 and 8 (32- and 64-bit)
  • Supply Power Type Battery
  • Temperature Accuracy ± 0.5 °C
  • Temperature Resolution 0.01 °C
  • Temperature Sensor Type Thermocouple
  • Thermocouple Resistance, Max 1000 Ω
  • Time Accuracy ± 1 minute/month
  • Width 184.2 mm
  • Wire Gauge 24 AWG

Supported Applications

The OM-CP-TCTEMPX Series is a family of multi-channel thermocouple temperature data loggers available in 4, 8, 12, and 16-channel configurations. Because each unit can monitor and record many thermocouple inputs at once, it is suited to multi-point temperature monitoring and thermal profiling where several locations must be tracked simultaneously.

Support for J, K, T, E, R, S, B, and N type thermocouples lets the loggers cover applications ranging from low-temperature environments to high-temperature process measurement. Individual cold junction compensation per channel and open channel detection make the series appropriate for demanding industrial and laboratory temperature recording, and each unit ships with a NIST traceable calibration certificate for quality and compliance documentation.

  • Multi-point industrial temperature monitoring
  • Thermal profiling across multiple locations
  • Laboratory and process temperature recording
  • Applications requiring NIST traceable calibration

Operating Conditions & Performance

The internal channels measure over a temperature range of -20 °C to +60 °C (-4 °F to +140 °F) with a resolution of 0.01 °C (0.018 °F) and a calibrated accuracy of ±0.5 °C (0 °C to 50 °C). The loggers operate in an environment of -20 °C to +60 °C (-4 °F to +140 °F) and 0 %RH to 95 %RH non-condensing.

Remote thermocouple channels connect through a female subminiature (SMP) connection and accept a maximum thermocouple resistance of 1000 Ω, <100 Ω recommended, with automatic cold junction compensation based on the internal channel. Accuracy is ±0.5 °C for J, K, T, E, N thermocouples and ±2.0 °C for R, S, B thermocouples.

The reading rate ranges from 4 Hz up to 1 reading every 24 hours. Memory capacity with all channels enabled is 524,032 readings per channel on the 4-channel model, 262,016 readings per channel on the 8-channel model, 174,677 readings per channel on the 12-channel model, and 131,008 readings per channel on the 16-channel model. Data is date and time stamped in °C, °F, K, °R, mV, V, and time accuracy is ±1 minute/month.

Each unit uses a 9 V lithium battery (included and user replaceable) with an 18 months typical battery life, and connects through a USB-A to micro USB cable (included) at 460,800 baud. Start modes include software programmable immediate start or delay start, up to 6 months in advance, with digital calibration through software. The series carries CE and ROHS approvals.

Configuration Options

The four members of the series differ primarily in channel count, physical size, weight, and memory depth. The 4-channel and 8-channel models share dimensions of 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) and weigh 13 oz (368 g). The 12-channel model measures 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm) and weighs 20 oz (580 g), while the 16-channel model measures 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm) and weighs 28 oz (800 g).

All variants accept the same thermocouple types and share the same accuracy and resolution behavior. Type J covers -210 °C to +760 °C, type K covers -270 °C to +1370 °C, type T covers -270 °C to +400 °C, type E covers -270 °C to +980 °C, type N covers -270 °C to +1300 °C, type R covers -50 °C to +1760 °C, type S covers -50 °C to +1760 °C, and type B covers +50 °C to +1820 °C.

Every variant provides individual cold junction compensation per channel, open channel detection, configurable channel names, and real time recording with a PC. The OM-CP-BAT103 replacement battery allows user servicing across all models.

Key Product Differences

  • OM-CP-QUADTCTEMP-A2 - 4-Channel Thermocouple Data Logger
  • OM-CP-OCTTCTEMP-A2 - 8-Channel Thermocouple Data Logger
  • OM-CP-X12TCTEMP-A2 - 12-Channel Thermocouple Data Logger
  • OM-CP-X16TCTEMP-A2 - 16-Channel Thermocouple Data Logger
  • OM-CP-BAT103 - Replacement 9V lithium battery
Rated 4 out of 5 by from Great Logger I like these little units however a little more user friendly option would make them a 5 star.
Date published: 2025-05-21
Rated 5 out of 5 by from Great purchase, go ahead and place your order It is a great datalogger. I recommend it as it is easy to use
Date published: 2023-08-07
Rated 4 out of 5 by from Great data logger with software that's easy to use Works great, though I'd like it if there was an option to see data real time when doing a custom start.
Date published: 2021-10-12
Rated 5 out of 5 by from The very best It is so easy to install and use, i’d lo e the software
Date published: 2020-11-23
Rated 5 out of 5 by from Rugged Stand-Alone TC Data Logger Rugged piece of equipment that allows stand-alone logging of thermocouple data in multiple environments. Very easy to set up with the free software that is found on the OMEGA website. Retrieving the data is even easier. Just be sure to charge the battery before logging, and select the correct sample rate to avoid running out of memory. Great piece of equipment, we will be buying more in the near future.
Date published: 2020-10-15
  • y_2026, m_9, d_1, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_CA, sid_OM-CP-OCTTCTEMP-A2, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

How can i change the sampling frequency?

Asked by: Phiona de Sitter
Thank you for your question. You must go to Custom Start in the software to change the logging interval.
Answered by: Application Engineer PV
Date published: 2023-10-16

Is there Mac version of the software?

Asked by: Alireza
Thank you for your question. There is no Mac version of the software. Only Windows.
Answered by: PVLENG
Date published: 2025-06-11

Is this Logger water resistant or water proof?

Asked by: josh25
Thank you for your question. No it is not water proof or water resistant.
Answered by: Application Engineer PV
Date published: 2022-07-05

Are LabVIEW drivers available for this device? If not, is there a serial programming manual or similar for writing my own?

Asked by: JFWW
Hello, thank you for your question. This logger can only be used with the provided proprietary software and APIs are not available. Please contact our Data Acquisition department for more information on devices compatible with LabView.
Answered by: DAS Engineer
Date published: 2026-04-06

My new device is not appearing in the connected devices window. I've verified that it does recognize the USB that it is plugged into. My older data loggers are working correctly. Can you please help me troubleshoot this?

Asked by: Anna1990
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2023-10-24

Is it possible to poll each channel via ascii command whenever I want to record the data to a 3rd party software?

Asked by: make or break decision
Thank you for your question. Unfortunately, there is no serial protocol available to poll logger just provided software.
Answered by: Raptor
Date published: 2023-09-05

I'm getting error when trying to export to excel &quot;Unable to export to Microsoft Excel: Return argument has an invalid type.&quot; Any thoughts why?

Asked by: Elect
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2022-11-10

Does the Data Logger comes with an extension to recharge the battery? If not, do we need to buy a new 9 V lithium battery? Thank you!

Asked by: mm1212
Thank you for your question. A 9 volt lithium battery is provided with the logger but this is not rechargeable and can be replaced by the user. https://www.omega.com/en-us/data-acquisition/data-loggers/p/OM-CP-BAT103
Answered by: Application Engineer PV
Date published: 2022-04-28
  • y_2026, m_9, d_1, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_22
  • loc_en_CA, sid_OM-CP-OCTTCTEMP-A2, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 5ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration