Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

OM-2628

Integrated Circuit Temperature Probes

Models In Stock
  • High Precalibrated Accuracy: ± 0.5°C (0.9°F) Maximum @ 25°C
  • Excellent Linearity: 0.15°C (0.27°F) Maximum [0 to 70°C (32 to 158°F)]
  • Wide Operating Temperature Range: -25 to 105°C (-13 to 221°F)
  • Single Supply Operation: +4 to +30V
OM-2628
From C$ 197.02
Models In Stock
Integrated Circuit Temperature Probes OM-2628 OM-2628
loading all models
Product Overview
  • Accuracy Detail Calibration Error @ 25°C (77°F) 0.3°C (0.54°F) typical, 0.5°C (0.9°F) maximum TA = 0 to 70°C (32 to 158°F): Error Over Temperature: 0.4°C (0.72°F) typical, 0.8°C (1.4°F) maximum Nonlinearity: 0.05°C (0.09°F) typical, 0.15°C (0.27°F) maximum TA = -25 to 105°C (-13 to 221°F): Error Over Temperature: 0.5°C (0.9°F) typical, 1°C (1.8°F) maximum Nonlinearity: 0.1°C (0.18°F) typical, 0.35°C (0.63°F) maximum
  • Forward Voltage ± 44 V
  • Insulation PFA
  • Linearity 0.15°C
  • Linearity Note Excellent Linearity: 0.15°C (0.27°F) Maximum [0 to 70°C (32 to 158°F)]
  • Long Term Stability 0.1°C/month
  • Long Term Stability Note 0.1°C/month (0.18°F) typical
  • Nominal Current Output 298.2 µA
  • Nominal Current Output Note Nominal Current Output @ 25°C (298.2 K): 298.2 µA typical
  • Package Temperature, Max 125 °C
  • Package Temperature, Min -45 °C
  • Probe Diameter 0.25 in
  • Probe Type Integrated Circuit Temperature Probes
  • Process Temperature, Max 105 °C
  • Process Temperature, Min -25 °C
  • Repeatability 0.1°C
  • Repeatability Note 0.1°C (0.18°F) typical
  • Reverse Voltage ± 20 V
  • Reverse Voltage Note Reverse Voltage (- to +) Lead Temperature: 20V maximum
  • Series ID OM-2628
  • Soldering 572 °C
  • Soldering Note Soldering, 10 Seconds: 572°C (1062°F) maximum
  • Temperature Coefficient 1 µA/°C
  • Temperature Coefficient Note 1 µA/°C typical
  • Temperature Probe Style Immersion Probe
  • Temperature Sensor Type Thermistor

Supported Applications

The OM-2628 Series is an Integrated Circuit Temperature Probe built around the AD592CN transducer — a two-terminal monolithic integrated circuit that provides an output current proportional to absolute temperature. It is designed for applications requiring high accuracy, linearity, and stability over a wide temperature range with minimal self-heating errors.

Because the transducer behaves as a high-impedance current source, it tolerates long lead runs and voltage drops without loss of signal, which suits appliance, automotive, and HVAC temperature sensing as well as general-purpose electronic temperature measurement.

Operating Conditions & Performance

The probe measures temperature over -25 to 105°C (-13 to 221°F) and outputs 1 µA/K, with a nominal current output of 298.2 µA typical at 25°C (298.2 K). Repeatability is 0.1°C (0.18°F) typical and long-term stability is 0.1°C/month (0.18°F) typical.

  • Accuracy: 0.5°C (0.9°F) maximum @ 25°C (77°F); 0.15°C (0.27°F) maximum @ 0 to 70°C (32 to 158°F).
  • Operating temperature: -25°C (-13°F) minimum, 105°C (221°F) maximum.
  • Storage (package) temperature: -45°C (-49°F) minimum, 125°C (257°F) maximum.
  • Power supply: 4 to 30V (4V minimum, 30V maximum).
  • Forward voltage (+ to -): 44V maximum.
  • Reverse voltage (- to +): 20V maximum.

Supply-voltage sensitivity is low: rejection is 0.2°C (0.36°F)/V maximum for 5V < Vs < 15V and 0.1°C (0.18°F)/V maximum for 15V < Vs < 30V. The probe body has a 6.4 mm (¼") diameter, and the temperature coefficient is 1 µA/°C typical.

Configuration Options

All models use the same AD592CN transducer and share the -25 to 105°C (-13 to 221°F) measurement range and accuracy behavior; the models differ in probe length and lead length rather than in sensing performance.

  • Probe length: the C1 configuration is a 38 mm (1.5 in) probe, while the C6 configuration is a longer 153 mm (6 in) probe, both 6.4 mm (¼") in diameter.
  • Lead length: the base configurations are supplied with 0.91 m (36") leads, and extended lead-length configurations of the C1 probe are offered with 72" and 144" leads.

Key Product Differences

The model lineup consists of the following probe configurations:

  • OM-2628-C1 — 38 L x 6.4 mm diameter (1.5 x ¼") AD592CN temperature probe with 0.91 m (36") leads.
  • OM-2628-C6 — 153 L x 6.4 mm diameter (6 x ¼") AD592CN temperature probe with 0.91 m (36") leads.
  • OM-2628-C1-72 INCH — C1 probe configured with 72" leads.
  • OM-2628-C1-144 INCH — C1 probe configured with 144" leads.
Rated 5 out of 5 by from Dependable We have used these for about a year now and they are performing well for us.
Date published: 2016-06-11
Rated 5 out of 5 by from IC Probe Probes work well, no issues yet. I wish they had longer lead wire.
Date published: 2023-07-18
  • y_2026, m_8, d_25, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_OM-2628-C1, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

What kind of controller would accept this probe? 4-20ma? I am currently using a plc with a temperature module and a 100 ohm rtd sensor which is very vulnerable to noise. My sensor wire run is about 30ft.

Asked by: Leeway
Thank you for your question. Unfortunately, this probe was only used with an obsolete Data Acquisition board that interfaced with AD592 sensors and there is no controller available to monitor this sensor.
Answered by: Application Engineer PV
Date published: 2021-04-20
  • y_2026, m_8, d_25, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_OM-2628-C1, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 5ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration