Need assistance? Call us: 1-800-663-4209
LDi-127
Heavy Duty, LVIT Linear Position Sensors with Rod Ends
Models In Stock
- Heavy-Duty, Long Lasting, Contactless Device
- Excellent Stroke-to-Length Ratio
- 27 mm (1.05') Diameter Anodized Aluminum Housing Sealed to IP67
- Wide Choice of Range: 25 to 450 mm (1 to 18') Full Scale
LDi-127
From
C$
1 147.65
Models In Stock
Product Overview
- Additional Features 1 Radial exiting cable and two swivel rod eye ends
- Additional Features 2 Heavy-Duty Industrial Units
- Bandwidth 300 Hz (-3 dB)
- Enclosure Ratings IP67
- Housing Material Anodized Aluminum
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -20 °C
- Relative Humidity 95% RH, non-condensing
- Resolution 0.025% of FS
- Series ID LDi-127
- Shock 1000 g, 11 ms
- Temperature Coefficient 0.015% of FS/°C
- Vibration 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Supported Applications
The Omega LDi-127 series comprises Heavy Duty Linear Variable Inductive Transducers (LVIT) designed for contactless linear position sensing. These sensors are engineered for factory automation and industrial or commercial applications, including solar cell positioners, wind turbine prop pitch and brakes, chute or gate positions on off-road or agri-vehicles, and packing equipment. The series is also suitable for industrial testing, laboratories, in-plant operations, and mobile equipment OEM applications.
Operating Conditions & Performance
The LDi-127 sensors operate within an ambient temperature range of -20 to 85°C (-4 to 185°F) with a humidity rating of 95% RH, non-condensing. The series features an IP67 enclosure rating and is constructed from Anodized Aluminum housing. Performance specifications include a typical accuracy of ±0.15% of Full Scale Output (FSO), with a maximum accuracy of ±0.25%. Resolution is specified at 0.025% of FS, and the nominal response time is 300 Hz.
Environmental durability ratings for the series include:
- Shock Rating: 1000 g, 11 ms
- Vibration Rating: 5 to 20 Hz at 0.5" p-p; 20 to 2000 Hz at 4.2 g p-p
Power and Output Requirements
The sensors require a DC power supply dependent on the output configuration:
- For 0-10 VDC output: 12 to 30V DC input.
- For 4-20 mA output: 18 to 30V DC input (minimum).
Note: The 4-20 mA DC output is a 3-wire sourcing configuration and should not be connected to a 2-wire loop-powered system.
Configuration Options
The LDi series offers configurable linear ranges from 25 mm (1") to 450 mm (18"). The sensors are available with two primary output signal types: 0-10 VDC or 4-20 mA. Each unit includes a radial exiting cable, 1 m (3.3') long, equipped with strain relief and two swivel rod eye ends for installation.
Wiring Configuration
The series supports field programmability via the white conductor or Pin B. The standard wiring assignments are:
- Red (Pin E): + Power Input (12-30 V DC)
- Black (Pin D): Common Ground
- Green (Pin A): Analog DC Output (0 - 10 V or 4 - 20 mA)
- White (Pin B): Field Programmability (calibration)
An alternative electrical connection option is available using a PTO2-10 6-pin connector.
Field Programmability Ranges
The sensors support field programmable calibration ranges:
- 0-20% Range: Configurable for 0-10 VDC or 4-20 mA output, with a maximum of 20% at both ends.
- 80-100% Range: Configurable for 0-10 VDC or 4-20 mA output, with a maximum of 20%.
The default setting is the full range (0 to Full Scale).
Housing and Dimensions
All models feature a housing diameter of 27 mm (1.05"). The overall length 'A' varies by measurement range, ranging from 114.3 mm (4.5") for the 25 mm model to 546.1 mm (21.5") for the 450 mm model.
Key Product Differences
The series is divided into two primary sub-series based on measurement range and physical length:
- LDI-127 Series: Covers linear ranges from 25 mm to 200 mm (1" to 8").
- LDI-128 Series: Covers linear ranges from 250 mm to 450 mm (10" to 18").
The LDI-119 is noted as a smaller body version intended for non-heavy-duty applications, distinct from the Heavy Duty LDi-127/128 series. Model numbers follow the structure LDI-<SERIES>-<RANGE>-<OUTPUT>-<OPTIONS>, where output codes denote 0 to 10 VDC (A010) or 4 to 20 mA (A020).
Show Ratings & Reviews
Rated 5 out of
5
by
pnucon from
Easy install and setup
Works well, fine repeatability We installed in old hydraulic forming press to automate a process and it fit the application well.
Date published: 2016-05-20
Rated 5 out of
5
by
B_Griffen from
Good product
Item received quickly with no issues. Item was easy to install. Documentation was accurate and easy to understand.
Date published: 2021-11-23
I am connecting a 4 wire LDI -119 to an iNet 1000C, What is the wiring diagram for the connections? I need to know what color wire goes to what input on the iNet device.
Thank you for contacting Omega Engineering. The LDI-119 is a three-wire connection and you will need an external power supply to connect it to an INET system. This answer is a bit involved and I would suggest you call and discuss this with an engineer in our Pressure and Strain department.
Date published: 2019-11-17
How do I reverse the output signal on a LDI-128-300-A020A? Retracted all the way equals 20mA. Extended all the way equals 4mA.
Hi, thanks for connecting with Omega. Unfortunately, it is not possible to change the direction of the output signal on the LDI series sensors. The field programming feature can be used to change to range over which the output signal applies, but it will always be an increasing signal for outward movement of the rod. Thank you and please feel free to contact us with any other questions you may have.
Date published: 2019-05-29