Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

HHM-EX623

Clamp Meter 400 A Dual Input with Non-Contact Infrared Thermometer and Voltage

Item# HHM-EX623

Product Specs

<< See all Product Models
Brand
AC Response True RMS (Aac and VAC)
Additional Features 1 400 A max Current
Altitude,Max 2000 m
Auto Power Off After approx. 30 minutes, with disable
Bandwidth 50 to 400 Hz (Aac and VAC)
Battery Indication Displayed
Capacitance 10pF to 40000μF
Capacitance Resolution 0.01nF
Clamp Jaw Opening Length 32 mm
Continuity Test Threshold 50 Ω; test current < 0.5mA
Crest Factor 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60 Hz and 5% to 100% of range)
Current Accuracy ± 1.5 %
Current Measurement Range 400 A/4000 μA
Current Resolution 10 mA
Diode Test Test current of 0.3 mA typical
Display Range Dual 40000/4000
Display Type Backlit LCD
Duty Cycle 0.5 to 99.0%
Frequency 40 MHz
Frequency Resolution 0.001Hz
Fuse Rating Ceramic Fast Blow, 500 mA
GrossWeightValue 1.67
Height 229 mm
Humidité de fonctionnement 0 to 80% RH
Impedance Input 10M Ω (Vdc and Vac)
Infrared Temperature Features IR Spectral Response: 6 to 16 um; IR Emissivity: 0.95 fixed; IR Distance Ratio : 8:1;Laser Pointer: Class 2 Laser
Laser Power < 1 mW
Laser Wavelength Color 630 to 670 nm
Length 49 mm
Plage de mesure de tension sans contact 100 to 600 Vac
Process Temperature, Min -50 °C
Resistance 40 MΩ
Resistance Resolution 0.01Ω
Sampling Rate 2 Hz (2 updates/second)
Series ID HHM-EX623-Clamp-Meter
Storage Humidity, Max < 80 %
Storage Temperature, Max 60 °C
Storage Temperature, Min -20 °C
Supply Power Type Battery
Température de fonctionnement, max 40 °C
Température de fonctionnement, min 5 °C
Température maximale du processus 270 °C
Tension en circuit ouvert 2.8 Vdc typical
Thermocouple Type K
Type de mesure AC/DC Voltage/Current, Resistance, Capacitance, Frequency, Dual Type K Temperature, IR
Voltage Measurement Range 600 V
Voltage Resolution 0.1 mV/0.01 mV
Weight 303 g
Width 80 mm
Échelle de mesure de la température, max 1000 °C
Échelle de mesure de la température, min -50 °C
Country of Origin China