CL900A-950A
Four d'étalonnage pour thermocouples et sondes RTD
Hot Point Dry Block Probe Calibrator With RS232 Output- Étalonne les thermistances, thermocouples et RTD en quelques minutes
- Haute précision ±0,8°C (±1,5°F) et stabilité exceptionnelle ±0,2°C (±0,3°F) pour des étalonnages précis
- Conception portable et robuste
- Large plage de température de l’ambiante +22 à 482°C (ambiante +40 à 900°F). Couvre la plupart des applications industrielles
Aperçu du produit
- Accuratezza ± 0,8 °C (± 1,5 °F)
- Accuratezza Dettagli (1° risoluzione) CL900A con inserti per pozzi di prova da 152 mm (6"): ±0,8°C (±1,5°F) CL900A con inserti per pozzi di prova da 101,6 mm (4"): ±1,7°C (±3°F) CL950A: ±0,8°C (±1,5°F)
- Funzionalità aggiuntive 1 Portatile
- Controllo Controllore digitale PID basato su Microprocessore
- Interfaccia dati RS232
- Altezza 312 mm
- Lunghezza 191 mm
- Temperatura di esercizio, max 38 °C
- Temperatura di esercizio minima 5 °C
- Consumo energetico 1050 W
- Consommation électrique Remarque 115 Vca, 50/60 Hz, 230 Vca, 50/60 Hz, 1050 W
- Température maximale du processus 482 °C
- Température minimale du processus 22 °C
- Température de service Remarque Ambiente da 22 a 482°C (ambiente da 40 a 900°F); Uniformità della temperatura (all’interno dei primi 25 mm/1" del Pozzo di Prova): CL900A con inserti per pozzo di prova da 152 mm (6"): ±0,3% lettura CL900A con inserti per pozzo di prova da 101,6 mm (4"): ±0,4% lettura CL950A: ± 0,3% lettura
- ID de série CL900A-950A
- Stabilité de la température ±0,15°C (±0,3°F)
- Poids 11.4 kg
- Type de puits Pozzetto singolo
- Largeur 363 mm
OMEGA’s hot point™ calibrator is part of a new family of calibrators which allows calibration of thermistor, thermocouple and RTD probes quickly and easily with an accuracy to ±0.8°C (±1.5°F). An integral RTD sensor assures high measurement accuracy and repeatability. A built-in microprocessor-based PID digital controller assures exceptional stability. Setpoint and actual temperature are displayed, simultaneously. Temperature can be set in one degree increments from Ambient +22 to 482°C (Ambient +40 to 900°F).
The CL900A calibrator accepts a variety of optional inserts which are available in 4" and 6" depths, and probe diameters from 1/8" to 3/8". An undrilled insert is also available. The CL900A comes standard with a 1/4" diameter, 6" deep insert well, and insert removal tongs. Additional inserts can be ordered separately as required for other diameter probes. 6" depth inserts are used for probes 7" and longer. 4" depth inserts are used for probes 5" and longer..