Product Overview
- Accuracy ± 0.1 %
- Air Consumption 0.05 SCFM
- Air Supply Pressure, Max 100 psi
- Air Supply Pressure, Min 5 psi
- Compliance Note FM Ratings: Explosion-proof for class I division 1, groups B, C, and D. T6, dust ignitionproof for class I, division 1, groups E, F, and G, T6; Intrinsically safe for class I, II, and III, division 1, groups C, D, E, F, and G, T4 hazardous (classified) locations and intrinsically safe for class I, zone 0, group IIB, T4 hazardous (classified) locations and suitable for class I, groups A, B, C, D, T4, and class II and III, division 2, groups F and G, T6 hazardous (classified) locations. CSA Ratings: Class I division 1, groups B, C, and D; Class I, division 2, groups A, B, C and D; Class II, division 1, groups E, F, and G; Class II and III, division 2, groups F and G.
- Deadband ±0.02% of span
- Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
- Enclosure Ratings Note Weatherproof NEMA 4X (IP66), explosion-proof and intrinsically safe
- Hysteresis ± 0.1% of span
- Input Control Signal 4 to 20 mA
- Materials Aluminum, Epoxy
- Measurement Type Current
- Media Compatibility Clean dry air / inert gas
- Operating Temperature, Max 160 °F
- Operating Temperature, Min -40 °F
- Output Capacity 4.5 SCFM at 25 psig Supply; 12.0 SCFM at 100 psig Supply
- Output Signal Pressure
- Port 1 Size 1/4 in
- Port 1 Type NPT Female
- Port 2 Size 1/4 in
- Port 2 Type NPT Female
- Measurement Pressure Type Gauge
- Repeatability ± 0.1% of span
- Series ID Series-2900
- Storage Temperature, Max 200 °F
- Storage Temperature, Min -40 °F
- Supply Power Type Loop Powered
- Weight 1.8 lb
Supported Applications
The Dwyer Series 2900 Current to Pressure Transducer converts a 4–20 mA electrical signal into a proportional pneumatic output for control systems operating in hazardous environments. Designed with advanced circuitry and electronic feedback, the series provides vibration-resistant performance suitable for field mounting on valves where mechanical shock or movement is present.
Documented applications include industrial compressed-air systems requiring precise current-to-pressure conversion. The unit's NEMA 4X housing and FM/CSA approvals support deployment in classified locations including Class I Division 1, Zone 0, and Dust Ignitionproof environments as specified by the certifications listed below.
Operating Conditions & Performance
The Series 2900 operates within an ambient temperature range of -40 to 160°F (-40 to 71°C) with a storage temperature capability from -40 to 200°F (-40 to 93°C). The transducer is not position sensitive and maintains performance under vibration, making it suitable for dynamic field installations.
Performance specifications include an accuracy of ±0.1% of span, hysteresis of ±0.1% of span, and repeatability of ±0.1% of span. The unit is loop powered and requires oil-free, clean dry air filtered to 40 microns as the supply media.
Supply pressure must be maintained at a minimum of 5 psig (0.3 bar) above the maximum output signal, with a maximum allowable input pressure of 100 psig (6.9 bar). The enclosure is rated Weatherproof NEMA 4X (IP66), explosion-proof and intrinsically safe.
Configuration Options
The series offers two primary output ranges configured via specific model numbers:
- Model 2913-E: Accepts a 4–20 mA input and provides an output of 3–15 psig (0.2–1.0 bar).
- Model 2916-E: Accepts a 4–20 mA input and provides an output of 6–30 psig (0.4–2.1 bar).
Housing construction utilizes chromate-treated aluminum with epoxy paint, weighing 1.8 lb (0.82 kg). The unit features a 1/2" female NPT electrical connection and a 1/4" female NPT process connection for air supply.
Approvals & Certifications
The Series 2900 holds CE, CSA, and FM approvals. Specific hazardous location ratings include:
- FM Ratings: Explosion-proof for Class I Division 1 Groups B, C, D (T6); Dust Ignitionproof for Class I Division 1 Groups E, F, G (T6). Intrinsically safe for Class I, II, III Division 1 Groups C–G (T4) and suitable for Zone 0 Group IIB (T4).
- CSA Ratings: Class I Divisions 1 & 2 Groups A–D; Class II Division 1 Groups E–G; Class II & III Division 2 Groups F, G.
Configuration Options
The unit includes easily accessible zero and span adjustments for field calibration. Input and output ports are located on both the front and back of the housing to facilitate installation flexibility. Dip switches allow configuration for direct acting, reverse acting, or split range operation.
Key Product Differences
The primary distinction between models in this series is the pneumatic output pressure range: Model 2913-E delivers a standard 3–15 psig signal, while Model 2916-E provides an extended 6–30 psig signal. Both variants share identical input requirements (4–20 mA), housing dimensions, environmental ratings, and hazardous location approvals.
Dimensions for the enclosure are listed as 2-3/16" width by 2-1/2" height with a depth of 2-5/64" in manual documentation; data sheet specifications list an overall diameter of 3-1/2" and height of 4-19/32", reflecting the inclusion of mounting features or conduit entries. The unit is not field repairable; if service is required, the entire transducer must be returned to the manufacturer.
PDFs & Manuals
Show Ratings & Reviews