Passer à la recherche Passer au contenu principal Passer à la navigation

Besoin d'aide? Appelez-nous: 1-800-663-4209

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

AM-2250-Controller

Contrôleur multivariable pH, ORP, conductivité par contact, débit

Multi-Variable Controller pH, ORP, Contacting Conductivity, Flow
Modèles en stock
  • Paramètres pH, ORP, conductivité et débit disponibles.
  • Affichage LCD rétroéclairé très visible.
  • Étalonnage flexible et facile, incluant l’étalonnage multi-points de conductivité pour acides et bases.
  • Trois relais de commande pour processus à montée ou descente.
AM-2250-Controller
À partir de C$ 1 882.29
Modèles en stock
Multi-Variable Controller pH, ORP, Contacting Conductivity, Flow AM-2250-Controller AM-2250-Controller
loading all models
Aperçu du produit
  • Fonctions supplémentaires 1 Contrôle PID, capteurs vendus séparément
  • Remarque sur l'étalonnage Modes d'étalonnage du pH : Automatique ou manuel 2 ou 3 points ; Modes d'étalonnage ORP : Manuel 1 point ; Modes d'étalonnage de la conductivité : Jusqu'à 16 points ; Modes d'étalonnage du débit : Saisie du facteur K
  • Remarque sur la conformité ETL (États-Unis et Canada) et CE en attente
  • Mesure de la conductivité 0,055 à 500 000 µS/cm
  • Dimensions de la découpe 5,4 x 5,4 po
  • Type d'affichage Écran LCD
  • Caractéristiques nominales du boîtier NEMA Type 4X
  • Indication de débit Remarque 0 à 999 dans toutes unités
  • Hauteur 5.5 in
  • Échelle d'entrée Remarque Entrée du capteur de pH : -600 à +600 mV ; Entrée du capteur ORP : -999 à +999 mV ; Entrée du capteur de conductivité : 0 à 9999 Ω ; Entrée du capteur de débit : 0 à 2000 Hz
  • Longueur 5 in
  • Orientation de montage Montage sur panneau ; montage mural
  • Nombre de relais 3
  • Humidité de fonctionnement 0 à 90 % HR
  • Température de fonctionnement, max 120 °C
  • Température de fonctionnement, min -20 °C
  • Plage de mesure ORP -1000 à +1000 mV
  • Détails de la sortie Deux sorties 4-20 mA, 4-20 mA évolutif avec PID (Processus), 4-20 mA évolutif (Processus ou Température), Optiquement isolé. Charge max - 800 Ω
  • Plage de mesure du pH 0 à 14 pH
  • Consommation électrique 0,2 A à 115 Vca ou 15 W
  • Température maximale du processus -20 °C
  • Température minimale du processus 70 °C
  • Relais Remarque 3 relais à contact sec avec circuit snubber, 10A à 120/240 VCA ou 8A à 30 VCC (charge résistive), 5A à 120/240 VCA ou 4A à 30 VCC (charge inductive) Modes de relais : Montée/Descente/Dans la plage. Options : Délai de relais, Cycle, Minuterie de suralimentation, Contournement, Un relais peut être déclenché par la température ou le totalisateur de débit.
  • Élément de détection 100/1000 Ω RTD ; 300/3K Ω NTC ou aucun
  • Remarque sur l'élément de détection PH, ORP, Conductivité : 100, 1000 Ω, RTD 300, 3K Ω NTC ou aucun
  • Remarque sur le type de capteur Capteur de pH : différentiel 6 fils ou combiné ; Capteur ORP : différentiel 6 fils ou combiné ; Capteur de conductivité : 4 fils en contact : toute constante de cellule entre 0,01 et 100 ; Capteur de débit : sortie impulsionnelle : roue à aubes, Magmete
  • ID de série AM-2250-Controller
  • Compensation de température Automatique : pH ; Automatique ou Manuel : Conductivité ; Affichage de la température : ORP ; Affichage du totalisateur de débit : Débit
  • Remarque sur la mesure de la température pH, ORP, Conductivité : -20 à 120 °C, Débit : Totalisateur de débit 0 à 999 dans n’importe quelle unité
  • Poids 2 lb
  • Largeur 5.5 in
The AM-2250 series is built on the legacy of the Shark and 2200 controllers. Like its predecessors it is designed to be the most flexible, easy to use, and easy to see multi-parameter controller on the market.

Four Parameters
Select the parameter you wish to measure from the easy-to-use menu. Choose Conductivity, pH, ORP or Flow. The user interface was designed under the principle that the user should not need to read the manual.

Three Relays
The AM-2250 provides control of external devices using its three independent control and alarm relays. Each relay has adjustable high, low, and in range set-points, cycle timer with adjustable on and off times. This feature enables tighter control of batch processes by eliminating chemical overshoot. Third relay can be activated by temperature or flow totalizer reading as well.

Analog Outputs
The AM-2250 provides two isolated, independent and scalable 4-20 mA outputs.
One 4-20 mA output can be configured for PID control. The second 4-20mA output can be set for process or temperature.

Zero Cards
The AM-2250 comes complete. There are no extra costs associated with buying boards for different sensors, or buying components to achieve NEMA 4X.

Enclosure
The AM-2250 is packaged in a rugged NEMA 4X polycarbonate enclosure making it ideally suited for indoor and outdoor heavy-duty applications. A mounting kit is included for surface and panel mounting. The enclosure outline makes panel-mount cutouts simple. Pipe mounting kits are available.

One Big Display
The AM-2250 features a backlit LCD display can be seen from a distance. The keypad allows easy entry of menu items and numeric values.

Calibration
No other controller offers the same combination of flexibility and ease for calibration. The process value is visible during calibration so the user knows when it has settled down. Calibration of pH can be with 2 or 3 points. Calibration of conductivity can take as many as 16 points so acids and bases can be measured through their conductivity. All Calibration data is stored.

Accessoires

accessories

Protecteur pour capteurs R5
C$78.45 / each
0 En stock
Protecteur pour capteurs R8
C$86.25 / each
0 En stock

consumables

Nettoyeur à jet pour capteur ODO
C$222.88 / each
0 En stock
Nettoyeur à jet pour capteurs R5
C$222.88 / each
0 En stock
Nettoyeur à jet pour capteurs R8
C$222.88 / each
0 En stock
Kit de remplacement de pont salin pour capteurs R5
C$196.59 / each
0 En stock
Kit de pont salin de remplacement pour capteurs R8
C$186.32 / each
1 En stock

installation hardware

Raccord de compression 1 1/2 po pour capteur de pH R5 (avec sortie 4-20 mA)
C$186.32 / each
0 En stock
Assemblage à dérivation chaude de 2 po incluant un bras d’extension pour capteur de pH R5
C$1 051.94 / each
0 En stock

sensors

Capteur en acier inoxydable 3/4 po avec raccord de compression en acier inoxydable 316, K=0,1
C$606.22 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression CPVC, K=0.01
C$927.13 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression en acier inoxydable 316, K=0,01
C$1 105.43 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression CPVC, K=10
C$659.70 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression en acier inoxydable 316, K=10
C$837.98 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression CPVC, K=50
C$659.70 / each
0 En stock
Capteur de conductivité en graphite 3/4 po avec raccord de compression en acier inoxydable 316, K=50
C$837.98 / each
0 En stock
Capteur en acier inoxydable 3/4 po avec raccord de compression CPVC, K=0,1
C$427.92 / each
0 En stock
Capteur en acier inoxydable 3/4 po avec raccord de compression en acier inoxydable 316, K=1
C$606.22 / each
0 En stock
Capteur de pH à insertion fixe combinée 1 po MNPT
C$436.84 / each
0 En stock
Capteur de pH à combinaison d'insertion variable avec raccord 3/4 po
C$561.64 / each
0 En stock
Capteur de pH différentiel à insertion fixe de 1 po, corps en Ryton, réparable sur site
C$1 060.85 / each
0 En stock
Capteur de pH différentiel 1 1/2 po Corps en Ryton Réparable sur site
C$1 060.85 / each
0 En stock
Capteur ORP à insertion fixe combinaison 1 po MNPT
C$525.97 / each
0 En stock
Capteur ORP à insertion variable avec raccord 3/4 po
C$650.79 / each
0 En stock
Capteur ORP différentiel à insertion fixe de 1 po, corps en Ryton, réparable sur site
C$1 060.85 / each
0 En stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Hello I need to implement dionized water in our process so ineed to implement a equiipment to verify if water has a good quality, someone recommended me the Item# AM-2250 but I want to ask you if so and what other accesories need to this process?

Asked by: Anonymous
Thank you for your inquiry. Please note that you may choose between measuring conductivity, pH, ORP, and flow rate with this device. The Accessories Tab will have the probe you can select for conductivity, pH ,or ORP available.
Answered by: Applications Engineer JJC
Date published: 2024-04-18
  • y_2026, m_7, d_6, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.46
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_AM-2250, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 45ms
  • QUESTIONS, PRODUCT
fr-CA
en_CA
Enregistrer la configuration