Models In Stock
- Plug-and-Play Multi-Use Temperature Data Logger with USB 2.0 Interface
- Accurate Thermistor Temperature Sensor
- No Special Software or Driver Required for Programming and Download
- Configuration Utility and Calibration Certificate Stored in the Data Logger
OM-22-Series
From
C$
175.63
Models In Stock
Product Overview
- Alarm Single Event, Cumulative, Disable*
- Alarm Delay 0, 5, 30, 45, 60, 90, 120 minutes
- Alarm Note Alarm Temperature: -30 to 75°C
- Battery life up to 3 mo
- Battery Size and Type CR2032, 3V Li-ion
- Data Interface USB
- Display Type LCD
- Form factor Handheld
- Height 45 mm
- LED Indicators REC, High/Low Alarm
- Length 110 mm
- Sampling Rate 30 Hz (30 updates/second)
- Sampling Rate Note 0, 5, 30, 45, 60, 90, 120 minutes and 24 hours
- Series ID OM-22-Series
- Software Compatibility Windows XP SP3/7/8/10
- Start Delay 0, 5, 30, 45, 60, 90, 120 minutes and 24 hours
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Power Type Battery
- Temperature Accuracy ± 0.5 °C
- Temperature Measurement, Max 70 °C
- Temperature Measurement, Min -30 °C
- Temperature Resolution 0.1°C, 0.1°F
- Temperature Sensor Type Note NTC Thermistor
- Weight 90 g
- Width 17 mm
Supported Applications
The OM-22, OM-23, and OM-24 are Multi-Use PDF Temperature and Humidity Data Loggers designed for monitoring temperature, or temperature with humidity, in applications subject to quality-control requirements. They are plug-and-play devices with a USB 2.0 interface and require no special software or driver to program the logger or download data.
On completion of a logging run each device generates PDF and Excel reports containing a summary, graph, and detailed data list, which suits cold-chain audits, warehouse and laboratory environmental monitoring, and shipment verification. Because the loggers are reusable, they fit repeated study cycles rather than one-time trips.
Operating Conditions & Performance
Across the series the temperature channel uses an NTC thermistor and covers -30 to 70°C (-22 to 158°F) with an accuracy of ±0.5°C and a resolution of 0.1°C, 0.1°F. The OM-24 adds a capacitive relative-humidity channel spanning 0.1 to 99.9% RH.
- Humidity accuracy (OM-24): ±3% RH from 10 to 90% RH @ 25°C, ±5% RH elsewhere.
- Humidity resolution (OM-24): 0.1% RH.
- Sampling interval: 30 seconds, 5, 10, 30, 60, 90, 120 minutes.
- Storage temperature: -40 to 85°C (-40 to 185°F).
- Power: Two 3V CR2032 lithium coin cell batteries.
- Weight: 90 g (3.2 oz).
- Dimensions: 110 L x 45 H x 17 mm D (4.3 x 1.8 x 0.7").
The loggers operate as multiple-use devices, provide LED indication of REC and high/low alarm status, and support single, cumulative, or disabled alarm types. All three models carry CE, RoHS, and EN 12830 Compliance.
Configuration Options
The three models share the same core temperature performance but differ in what they sense, how they store data, and how they are sealed:
OM-22 — Temperature
The OM-22 records ambient temperature only, dedicating its full 48,000 points of memory to the internal temperature channel. It carries the highest enclosure rating in the family, NEMA 6 (IP67).
OM-23 — Temperature + External Temperature
The OM-23 adds an input for an external temperature probe, splitting memory as 24000 Temp + 24000 ext. Temp. It is rated NEMA 4 (IP65). The external probe is sold separately as the OM-23-TP1 (with handle) or OM-23-TP2 (without handle).
OM-24 — Temperature + Humidity
The OM-24 pairs the internal temperature channel with a capacitive relative-humidity sensor measuring 0.1 to 99.9% RH, storing 24000 Temp + 24000 Humidity. It is rated NEMA 4 (IP65), not including the sensor area.
Key Product Differences
The model lineup and its external probe accessories are:
- OM-22 — multi-use PDF temperature data logger, ambient temperature.
- OM-23 — multi-use PDF temperature data logger, ambient temperature plus input for external temperature probe (external probe sold separately).
- OM-24 — multi-use PDF temperature and humidity data logger.
- OM-23-TP1 — external temperature probe (with handle) for OM-23.
- OM-23-TP2 — external temperature probe (without handle) for OM-23.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
SciGuy_GL from
Simple, efficient and effective datalogger
Dataloggers were just what I needed to provide ongoing monitoring of production and storage rooms. The visual display is a bonus. The built in software is perfect for setting up parameters and the printout macros are simple and effective. Also like the fact that the certification information for each unit appears in the report printouts.
Date published: 2021-10-17
Rated 5 out of
5
by
Sean S from
Great product for pack out testing
Very solid yet simple device that provides much data.
Date published: 2026-04-03
We are interested in purchasing a data logger. This would be suitable to read packages shipped with dry ice? Thank you
As long as units min temp does not exceed -30°C (-22°F). The display will not work at is temp range only above 0 deg c. The OM-CP-CRYO-TEMP is better suited for this application.
https://www.omega.com/en-us/control-and-monitoring-devices/data-loggers/om-cp-cryo-temp-series/p/OM-CP-CRYO-TEMP?searchterm=OM-CP-CRYO
Date published: 2020-06-09
With what operation system works? Windows only, IOS, Chrome?
Thank you for your question. Windows operating system only.
Date published: 2022-02-07
Does this calculate MKT? Included on the report?
Thank you for your question. It does calculate MKT. Please download Data sheet from page.
https://www.omega.com/en-us/temperature-measurement/temperature-and-humidity-data-loggers/om-22-series/p/OM-22
Date published: 2021-01-29
Can the USB port be connected with a cord or does it have to be directly plugged into a computer?
Thank you for your question. The logger has to be directly plugged into PC usb port in order to work properly.
Date published: 2020-07-17
Can the OM-25 USB port be connected with a cord or does it have to be directly plugged into a computer?
Thank you for your question. The OM-22/23/24 series has to be connected directly to USB port.
Date published: 2020-07-17
How many days can the temp be recorded?
Thank you for your question. Logger stores 48,000 points and the logger interval selected ( 30 seconds to every 2 hrs ) will determine time duration.
Date published: 2024-02-20
Do these loggers support PDF/A output for data integrity?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2025-07-11
Is the OM-24 suitable to measure temperature and humidity in cold storage units such as Carons and Continental refrigerators?
Thank you for your question. As long as environment conforms to specification. Keep in mind the humidity accuracy is based on 25 deg c.
Date published: 2023-03-09