  • Accuracy Detail Provided with a transducer output impedance of 2.4 kΩ into a calibration load of 20 kΩ at 20°C (68°F); variations in these parameters will change performance
  • Additional Features 1 Miniature DC Displacement
  • Bandwidth 50 Hz (-3 dB)
  • Cable Length 2 m
  • Cable Type Insulated Shielded
  • Compensated Temperature, Max 80 °C
  • Compensated Temperature, Min -20 °C
  • Core Material Ni/Fe—Radio Metal 50
  • Electrical Connection Pigtail Leads
  • Electrical Output DC
  • Enclosure Ratings IP67
  • Housing Material 400 Stainless Steel
  • Input Current 10 mA
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -20 °C
  • Output Ripple <1%
  • Series ID LD400
  • Supply Voltage 10 to 24 Vdc
  • Weight 26 g

Supported Applications

The Omega LD400 series consists of miniature DC output linear variable displacement transducers (LVDTs) designed to measure displacements up to ±5.0 mm (±0.20"). These self-contained units accept a regulated DC input and provide a DC voltage output relative to armature position, utilizing hybrid ICs including an oscillator, demodulator, and filter. The series is engineered for applications in civil, mechanical, chemical, and production engineering where high linearity and low mass of moving parts are required.

Operating Conditions & Performance

The LD400 transducers operate within a compensated temperature range of -20 to 80°C (-4 to 176°F). The series delivers an accuracy (linearity) of 0.3% FS and features infinite resolution for detecting the smallest movement identifiable by associated instrumentation. Electrical performance includes an excitation requirement of 10 to 24 Vdc regulated, with a frequency response of 50 Hz at -3 dB and ripple less than 1% FS.

Response time varies by model stroke: LD400-1 and LD400-2.5 models exhibit a 5 ms response time, while the LD400-5 model provides a 3 ms response time. Thermal effects on zero are specified as less than 0.02% FS/°C for the LD400-1 and less than 0.01% FC/°C for the LD400-2.5 and LD400-5; sensitivity thermal drift is less than 0.025% FC/°C.

Configuration Options

The series offers three distinct stroke configurations, each with specific dimensions and weights:

  • LD400-1: ±1.0 mm (±0.04") stroke; 75 mV/V/mm sensitivity.
  • LD400-2.5: ±2.5 mm (±0.10") stroke; 75 mV/V/mm sensitivity.
  • LD400-5: ±5.0 mm (±0.20") stroke; 54 mV/V/mm sensitivity.

Mechanical construction features a free-guided armature with acetal bearings to provide near-frictionless motion. The case material is 400 Series stainless steel, and the core utilizes Ni/Fe—Radio Metal 50. Each unit includes an M2 threaded core for connection.

Key Product Differences

The primary distinction among models lies in stroke length, which influences sensitivity values and physical dimensions. The LD400-1 and LD400-2.5 share identical body weights of 26 g (1.02 oz) and core weights of 1.0 g (0.04 oz), with overall dimension A at 21.5 mm (0.85 in). The LD400-5 model has a slightly shorter diameter (A: 20.5 mm / 0.81 in) but increased length and weight, totaling 30 g (1.18 oz) for the body.

Electrical connections are provided via a 2.9 m (9') shielded, color-coded cable with specific pinouts: Red (+ Excitation), Blue (- Excitation), White (+ Signal*), Green (- Signal), and Yellow (No connection). The white signal wire is in phase for positive inward displacement.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 7ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What is the resolution of this sensor ?

Asked by: ROHITH
Rohith typically resolution on LVDTs will be infinite, but you will read accurately to the second decimal typically. Most times it will be defined by the number of digits on your readout or DAQ system. Thank you.
Answered by: SAE DJO
Date published: 2019-11-16

Is there a repalcement for the LD400-1's pin? I see that there is one for the 2.5 and 5mm version under the &quot;LD400-X-CORE/ASSEMBLY&quot;, but there does not appear to be one for the 1mm version.

Asked by: CFTHOR
Thank you for your inquiry, Unfortunately, we do not carry the Core Assembly for the LD400-1
Answered by: rkent
Date published: 2022-05-06

Is it possible to just order the pin? This part bends and does not necessarily need the entire LVDT replaced, just the pin in the center.

Asked by: Anonymous
Yes. Part number for the replacment core is LD400-5-CORE/ASSEMBLY Cost $94.31 eaach
Answered by: Applicatrions Engineer JK
Date published: 2020-09-29

Does the LD400 have any environmental protection? What is the IP rating?

Asked by: Cewell
There are no IP or NEMA ratings for the the LD400 displacement sensor.
Answered by: Applicatrions Engineer JK
Date published: 2022-10-12

Do these sensors come with signal conditioners? If not, which signal conditioners do you offer are most compatible with these sensors?

Asked by: AJKJD
The LD400-5 has a 54mV/V/mm sensitivity. It can be powered by a regulated DC Voltage between 10V and 24VDC. If you used the high end excitation of 24VDC (54mm X 24VDC X 5mm) you would be getting a +/- 6.480 VDC output signal from the sensor. You may required signal conditioning
Answered by: Applicatrions Engineer JK
Date published: 2021-02-12
  • y_2026, m_8, d_13, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_LD400-1, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 45ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration