Product Overview
  • Accuracy ± 0.75 %
  • Approvals CE
  • Battery Backup 9 V Alkaline Battery
  • Cable Length 50 ft
  • Conductivity > 20 µS/cm
  • Display Note 128 x 64 dot-matrix LCD
  • Display Type LCD
  • Empty Pipe Detection Hardware/software, conductivity-based
  • Enclosure Ratings IP68, NEMA 6P
  • Material Construction Option N/A
  • Materials Steel, Epoxy, Aluminum
  • Media Compatibility Conductive liquids, Corrosive chemicals / acids / bases, Saltwater / brines
  • Number of Digits 8
  • Number of Outputs 1
  • Operating Pressure, Max 150 psi
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -12 °C
  • Output Detail 4 to 20 mA
  • Output Pulse Rate, Max 200 pulses/sec
  • Output Signal Current
  • Process Connection Type ANSI Flange
  • Pulse Rate Note User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5 ms, 200 pulses/sec max. For battery option meters, pulse width varies with frequency, 150 pulses/sec max
  • Series ID FMG480-Series
  • Storage Temperature, Max 70 °C
  • Storage Temperature, Min -40 °C
  • Velocity, Max 10 m/s

Supported Applications

The FMG480 Series is a spool-type electromagnetic flowmeter built for irrigation service in 3" to 12" pipe. With no moving parts, it presents an unobstructed bore and resists the wear caused by debris carried in ground or surface water. Because there are no bearings to seize or propellers to stall, maintenance demands are minimal, and the meter's modest straight-pipe requirement simplifies installation on crowded skids.

Suited to ground or surface water, the FMG480 pairs a rugged spool body with an integrated display and both pulse and 4 to 20 mA outputs, making it a practical choice for agricultural water management, well-head metering and distribution monitoring.

Operating Conditions & Performance

The meter reads reliably from a low-flow cutoff of 0.5% of maximum flow rate up to 10 m/sec. Accuracy is ±0.75% of reading plus ±0.025% of full-scale flow from the low-flow cutoff to the 10 m/sec maximum.

Process temperature is rated -12° to 60°C, with a storage range of -40° to 70°C. Line pressure is rated to 10.3 bar. The electronics housing is powder-coated diecast aluminum carrying a NEMA 6P, IP68 rating, rated for submersion to 3 m depth continuously. The meter is CE certified to EN 61326.

Electrodes are 316 stainless steel. DC-powered units accept 9-36 Vdc at 250 mA maximum (30 mA average), while AC units run on 85-264Vac, 50/60Hz at 0.12A. The current loop drives up to a 650 Ω maximum load, and the standard power/output cable is a 6 m polyurethane-jacketed lead, with lengths available on request.

Configuration Options

All 24 catalogue variants share the same measuring principle but differ by pipe size, wetted construction, power input and output configuration. The 3" body is ductile cast iron with a Noryl® liner and an EPDM O-ring, whereas the 4"-12" bodies are welded steel with an epoxy coating and a Santoprene flange/Polypropylene liner.

Size drives the physical envelope: length grows from 311 mm on the 3" meter to 500 mm on the 12", while shipping weight climbs from 17.5 kg to 77 kg across the same span. Power configurations cover AC and DC input, and every unit offers scaled pulse and 4-20mA outputs; built-in data logging is available as an option.

Key Product Differences

The lineup spans six pipe sizes, each offered in AC- and DC-powered forms (for example FMG480-03-A5, FMG480-03-D5, FMG480-12-A6 and FMG480-12-D6):

  • 3" — length 311 mm, height 179.8 mm, bore 66.04 mm, shipping weight 17.5 kg
  • 4" — length 257 mm, height 211 mm, bore 79 mm, shipping weight 15.5 kg
  • 6" — length 307 mm, height 231 mm, bore 128 mm, shipping weight 22.5 kg
  • 8" — length 359 mm, height 257 mm, bore 164 mm, shipping weight 32 kg
  • 10" — length 459 mm, height 284 mm, bore 219 mm, shipping weight 59 kg
  • 12" — length 500 mm, height 310 mm, bore 268 mm, shipping weight 77 kg

All variants use 150 lb. ANSI pattern flanges.

Accessories

cables

DC POWER/OUTPUT CABLE - 8 CONDUCTOR-20FT
C$199.27 / each
4 In Stock
DC POWER/OUTPUT CABLE - 8 CONDUCTOR-50FT
C$359.04 / each
0 In Stock

installation hardware

NSF GASKET KIT 12"
C$504.45 / each
0 In Stock
NSF GASKET KIT 10"
C$335.71 / each
0 In Stock
NSF GASKET KIT 3"
C$96.76 / each
2 In Stock
NSF GASKET KIT 4"
C$132.32 / each
0 In Stock
NSF GASKET KIT 6"
C$191.56 / each
2 In Stock
NSF GASKET KIT 8"
C$254.93 / each
0 In Stock
(1) GROUNDING RING FOR 3" METER
C$217.22 / each
0 In Stock
(1) GROUNDING RING FOR 6" METER
C$238.20 / each
0 In Stock
(1) GROUNDING RING FOR 8" METER
C$297.57 / each
0 In Stock
(1) GROUNDING RING FOR 4" METER
C$231.60 / each
3 In Stock
(1) GROUNDING RING FOR 10" METER
C$362.64 / each
0 In Stock
(1) GROUNDING RING FOR 12" METER
C$369.81 / each
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Operating Temperature is stated as 60 deg C, is that the max temp of the media flowing through the meter?

Asked by: Geobyteman
Thanks for the question. Yes, the 60°C specification refers to the maximum temperature of the liquid flowing through the meter.
Answered by: HPOAE
Date published: 2025-06-24

would this unit have CSA or ULC approval?

Asked by: tioui
Thanks for your question but unfortunately no. FMG flowmeters we offer do not have CSA or ULC approvals.
Answered by: HPOAE
Date published: 2024-08-22

Does the display head swivel, so that I can change the orientation for easier visuals

Asked by: Ccombee
Thank you for your inquiry. The magnetic flow meter's display does not swivel. It is integrated and best to get the remote version.
Answered by: Applications Engineer JJC
Date published: 2024-04-30

Does this unit comply with the Buy American Build American Act (BABA)?

Asked by: jac45
This unit does not comply with Buy American Build American Act (BABA)
Answered by: Application Engineer MC
Date published: 2024-11-26
  • y_2026, m_8, d_11, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_FMG480-03-A5, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration