  • NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Zero and span controls provides easy calibration checks and shorter installation time to get device running and monitoring
  • High precision accuracy at low pressure ranges provides exceptional accuracy for insuring tight-control and minimizing costly out of specification conditions
Series-616WL
From C$ 1,204.07
Models In Stock
Low Pressure Differential Pressure Transmitter, ± 0.50% Accuracy, 4-20 mA Series-616WL Series-616WL
loading all models
Product Overview
  • Accuracy Detail ± 0.50% FS, display accuracy ± 0.5%
  • Electrical Connection Screw Terminal
  • Enclosure Ratings IP66, NEMA Type 4X
  • Long Term Stability ± 1% FS/year
  • Materials, Wetted Consult Factory
  • Media Compatibility Clean dry air / inert gas, HVAC / room air, Inert / non-reactive gases, Helium, Nitrogen, Non-Conductive Gases, Non-Corrosive Dry Gases
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -17.8 °C
  • Measurement Pressure Type Differential
  • Process Connection Note Barbed, dual size to fit 1/8˝ and 3/16˝ (3.12 and 4.76 mm) ID rubber or vinyl tubing
  • Process Connection Size 1/8 in, 3/16 in
  • Process Connection Type Stepped Barb Fitting
  • Series ID Series-616WL
  • Span Adjustment Push Button
  • Supply Power Type DC
  • Zero Setting Adjustable Range Digital, push-button adj

Supported Applications

The Dwyer Series 616WL is a differential pressure transmitter designed to sense very low pressures of air and non-combustible, compatible gases. The unit converts these measurements into a standard 4-20 mA output signal suitable for process monitoring systems.

  • Measurement types: Positive, negative, and differential pressures
  • Service media: Air and non-combustible, compatible gases (wetted materials require factory consultation)

Operating Conditions & Performance

The Series 616WL operates within an ambient temperature range of 0 to 140°F (-17.8 to 60°C), with compensated performance specified between 32 to 120°F (0 to 48.9°C) per the instruction manual or 20 to 120°F (-6.67 to 48.9°C) per the data sheet; both sources confirm a thermal effect of ±0.02% F.S./°F (0.036% F.S./°C) from 77°F (25°C). The transmitter delivers full span accuracy of ±0.50% F.S., with display models offering ±0.5% display accuracy and stability rated at ±1% F.S./yr.

  • Power supply: 12-30 VDC (2-wire)
  • Loop resistance: DC; 0 to 900 Ω maximum
  • Current consumption: DC; 38 mA maximum

Configuration Options

The series is factory calibrated to specific ranges and offered with or without a 3-digit LCD digital read-out. Models are enclosed in a weatherproof polycarbonate case rated NEMA 4X (IP66). Process connections utilize integral barbed fittings dual-sized to fit both 1/8" and 3/16" (3.2 and 4.8 mm) I.D. rubber or vinyl tubing, while electrical connections are made via a screw-type terminal block.

Available Pressure Ranges

  • 0-0.25 in w.c. / 0 to ±0.25 in w.c.
  • 0-1 in w.c. / 0 to ±1 in w.c.
  • 0-60 Pa / 0 to ±60 Pa
  • 0-250 Pa / 0 to ±250 Pa

Configuration Options

  • Display: Standard or with LCD digital read-out (e.g., model suffix -LCD)
  • Calibration Certificate: NIST traceable calibration certificate available via the -NIST option code
  • Housing Mounting: Vertical orientation; consult factory for other position orientations

Key Product Differences

Variants within the Series 616WL differ primarily by pressure range and the inclusion of a digital display. Models without an LCD (e.g., 616WL-2) weigh 17 oz (482 g), while models with an LCD (e.g., 616WL-2-LCD) weigh 18 oz (510 g). Maximum pressure ratings vary by range: units in the 0.25 and 1 in w.c. ranges list maximum pressures of 2 psig or 4 psig respectively, while Pa-based models specify limits of 13.8 kPa or 27.6 kPa depending on the specific model variant.

  • Zero and Span Adjustments: Internal digital push-button adjustments allow for field calibration checks; these controls are not intended for re-ranging to a significantly different span

Accessories

Static Pressure Sensors for Manometers & Gages across Air Filters
From C$3.77
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 28ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration