Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

Model-DL7

Low Pressure Data Logger, 0.04s-8h Sampling, 21,500 Readings, HVAC Use

Model-DL7
From C$ 3 008.41
Low Pressure Data Logger, 0.04s-8h Sampling, 21,500 Readings, HVAC Use Model-DL7 Model-DL7
loading all models
Product Overview
  • Accuracy Detail ± 0.05 w.c. (up to 2˝ range) ± 0.1 (5˝ and 10˝ range)
  • Battery Size and Type 3.6V Li-ion
  • Clock Accuracy ± 2 s/day + one sampling interval
  • Compensated Temperature, Max 158 °F
  • Compensated Temperature, Min 32 °F
  • Input Type Temperature, Differential Pressure
  • Drift ± 0.5% FS/yr
  • Hysteresis ± 0.05%
  • Materials Polyphenylene ether, Polystyrene
  • Measurement Type Temperature, Differential Pressure
  • Media Compatibility Clean dry air / inert gas, Inert / non-reactive gases, Clean Dry Air, Helium, Nitrogen, Non-Corrosive Dry Gases
  • Memory 21,500 Readings
  • Non-Linearity ± 0.05% FS
  • Number of Channels 2
  • Operating Temperature, Max 158 °F
  • Operating Temperature, Min -40 °F
  • Power Consumption 5 to 10 µA
  • Pressure Accuracy ± 0.05 inH2O
  • Measurement Pressure, Min -0.5 inH₂O
  • Process Connection Size 1/8 in
  • Process Connection Type Id Tube
  • Proof Pressure 4x Full Scale
  • Relative Humidity 0 to 95%, Non-Condensing
  • Repeatability ± 0.05%
  • Resolution ± 0.01 in w.c, 12 bits (1 in 4096)
  • Resolution Note Internal Thermistor Resolution: 0.7°F (0.4°C), R25 value equal to 10,000Ω [10kΩ @ 25°C (77°F)]
  • Sensor Type Internal Thermistor and Differential Pressure Sensor
  • Series ID Model-DL7
  • Stop Modes Adjustable Delay Stop
  • Supply Power Note 3.6 V TL5134 Lithium Metal Battery, internal, Factory Replaceable
  • Supply Power Type Battery
  • System Requirements IBM compatible 386 or above and Windows® 3.1 or later with 2 MB RAM and 2 MB hard drive disk space, one serial port
  • Temperature Accuracy ± 0.5%
  • Temperature Resolution 0.7 °F
  • Weight 4 oz

Supported Applications

The Dwyer Series DL7 is a battery-powered differential pressure data logger that also measures and records temperature. It is a self-powered, two-channel unit with an on-board thermistor for ambient temperature, and it operates independently of an external power supply. Recorded data is later analyzed with Trendreader software on an IBM PC or 100% compatible computer.

  • Low differential pressure logging for air and noncorrosive gases in HVAC and airflow work.
  • Combined pressure and temperature recording, with an on-board thermistor channel.
  • Stand-alone field deployment, powered by a built-in lithium battery for extended unattended runs.

The pressure sensor is compatible with non-corrosive gases and air and is not to be used for liquid pressure measurement. Pressure connections should be made separately from the module and logger. The DL200 Windows software (sold separately) is used to program the logger and upload data.

Operating Conditions & Performance

The DL7 is a two-channel logger (internal thermistor plus a differential pressure sensor). Pressure range is model-specific and is listed under Configuration Options; performance common to the series is:

  • Accuracy: ±0.05" w.c. (up to 2" range) ±0.1 (5" and 10" range); thermal accuracy ±0.5% FS.
  • Resolution: ±0.01 in w.c.; 12 bits (1 in 4096).
  • Nonlinearity: ±0.05% FS (BFSL); hysteresis and repeatability ±0.05% FS; drift ±0.5% FS/yr.
  • Internal thermistor range: -40 to 158°F (-40 to 70°C); compensated temperature range 32 to 158°F (0 to 70°C).

Memory holds 21,500 readings, and the sampling rate is selectable from 0.04 s to 8 hrs (continuous sampling is not available from 40 ms to 8 s). Clock accuracy is ±2 s/day plus one sampling interval, and internal thermistor resolution is 0.7°F (0.4°C). The unit withstands 4X rated pressure, connects through two 1/8" ID permanent protective tubing ports, and operates at 0 to 95% RH, non-condensing. Power is a factory-replaceable 3.6 V LT5134 lithium metal battery, the housing is polyphenylene ether and polystyrene (PPE & PS), and the logger weighs 4 oz (110 g). It is CE marked.

Configuration Options

All five models share the same electronics, memory, resolution, temperature channel, and construction; they differ only in differential pressure range:

  • DL70: ±0.5 in w.c. (1.2 mbar).
  • DL71: ±1 in w.c. (2.5 mbar).
  • DL72: ±2 in w.c. (5.0 mbar).
  • DL75: ±5 in w.c. (12.4 mbar).
  • DL710: ±10 in w.c. (24.9 mbar).

Key Product Differences

The series follows the model guide DL7 plus a model-variant suffix, each defined by its pressure range:

  • DL70: range of ±0.5 in w.c. (1.2 mbar).
  • DL71: range of ±1 in w.c. (2.5 mbar).
  • DL72: range of ±2 in w.c. (5.0 mbar).
  • DL75: range of ±5 in w.c. (12.4 mbar).
  • DL710: range of ±10 in w.c. (24.9 mbar).

Accessories

cables

DL202 TR 2 SW USB W/ INT CABLE
C$649.18 / each
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 20ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration