Series-DFS2

Low Limit Freeze Protection Switch – Adjustable Set Point to 1 °C

Models In Stock
  • Vapor-filled copper capillary sensing element
  • Joint spring protector at capillary-bellow connection
  • Set point safety-lock protection and simple adjustment
  • Easy installation and wiring
  • Automatic and manual reset
Series-DFS2
From C$ 444.97
Models In Stock
Low Limit Freeze Protection Switch – Adjustable Set Point to 1 °C Series-DFS2 Series-DFS2
loading all models
Product Overview
  • Applications HVAC, Oil
  • Capillary Overload Temperature 392 °F
  • Capillary Temperature Note 392°F (200°C), maximum 60 minutes
  • Deadband 1.8 °F
  • Electrical Connection M20 Female Conduit with Strain Releif and Screw Terminal block
  • Enclosure Ratings IP40, NEMA Type 1
  • Insertion Length 0 in
  • Low Level Setpoint Factory Set: 39°F (4°C), and Safety Lock Secured; Adjustment via Screwdriver Slot.
  • Materials Galvanized Steel, ABS, Copper
  • Operating Temperature, Max 54 °F
  • Operating Temperature, Min 14 °F
  • Process Temperature, Max 0 °F
  • Process Temperature, Min 0 °F
  • Relative Humidity 0 to 95 %, Non-Condensing
  • Sensing Element Vapor-Filled Capillary
  • Series ID Series-DFS2
  • Storage Temperature, Max 158 °F
  • Storage Temperature, Min 14 °F
  • Switch Rating 15 A @ 24 to 250 Vac
  • Weight 1.6 lb
  • Wire Gauge 14 AWG

The Series DFS2 Low Limit Freeze Protection Switch protects cooling coils in air handler systems by preventing frost build up. The thermostat and its capillary sensing element provide an antifreeze function by sensing the lowest temperature along any one foot section of capillary. The DPDT manual or automatic reset relays signal the building management system as well as cut off the fan. The Series DFS2 will detect temperature drops below the fixed safety value (set point) which can be set as low as 34°F (1°C) utilizing the visual set point indicator and set point screw.

Product Applications

  • HVAC equipment
  • Heat exchangers and cooling coils

Accessories

installation hardware

A-DFS2-C CAPILLARY MTG CLIPS
C$26.20 / each
12 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 19ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration