Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FSW9000-Series

Liquid Flow Transmitter and Switch with Visual Indication

Models In Stock
  • High Reliability — No Moving Parts
  • 4 to 20 mA, PNP/NPN (Transistor), or Relay Output
  • Excellent Low Flow Sensitivity
  • Can Operate in Temperatures up to 120°C (248°F) with Sanitary Option
FSW9000-Series
From C$ 915.54
Models In Stock
Liquid Flow Transmitter and Switch with Visual Indication FSW9000-Series FSW9000-Series
loading all models
Product Overview
  • Accuracy ± 5 %
  • Adjustments Potentiometer
  • Enclosure Ratings IP65, NEMA 4
  • Flow Indication 8 LED Bar Graph
  • Linear Flow Rate, Max 2 m/s
  • Linear Flow Rate, Min 0.04 m/s
  • Materials, Wetted 316 Stainless Steel
  • Media Compatibility Liquids
  • Operating Pressure, Max 4351 psi
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Output Signal 4 to 20 mA
  • Probe Diameter 0.625 in
  • Process Temperature, Max 80 °C
  • Process Temperature, Min -20 °C
  • Repeatability ±1%
  • Response Time 3 to 10 sec
  • Series ID FSW9000-Series
  • Weight 1.5 lb

Supported Applications

The Omega FSW-9000 Series comprises liquid flow transmitters, sensors, and switches designed for measurement and control applications. The series measures liquid flow velocity in pipes using a conical sensor tip that allows installation at almost any angle without affecting accuracy. Configurations include the compact FSW-9000 transmitter with visual indication, the separate-sensor FSW-91-R model suitable for very small pipes (e.g., 3/8" or 9.5 mm), and remote control options via the FSCN-91 relay.

Operating Conditions & Performance

The series operates within a process temperature range of -20 to 80°C (-4 to 176°F). A sanitary option extends this capability to 284°F for CIP applications. Ambient operating temperatures are rated from -20 to 60°C (-4 to 140°F). The maximum working pressure is specified as 300 bar (4,500 PSI) in the manual and 300 bar (4351 psi) in the data sheet table. Flow velocity measurement ranges cover 0.04 m/s to 2.0 m/s for water.

Performance specifications include an accuracy of ±5% of setpoint and repeatability of ±1% of setpoint. The device features a nominal response time of 3 to 10 seconds with a maximum start-up delay of 12 seconds. Wetted materials are constructed from 316 Stainless Steel, and the series can be coated for aggressive mediums by adding an "-ETFE" suffix.

Configuration Options

The FSW-9000 Series offers configurable process connections, enclosure types, insertion lengths, and output signals to accommodate diverse installation requirements. The electronics utilize microprocessor-based design with self-calibration for temperature compensation.

  • Process Connections: Available in ½ NPT thread, ¾ NPT thread, 1 NPT thread, 1.5" Tri-Grip™ (inches only), and 2" ANSI flange, 150# 316 SS.
  • Enclosures: Standard glass-filled nylon with ½ NPT conduit, cable gland, and 2 m (6.5') cable; optional aluminum die cast enclosure available for hazardous environments or specific mounting needs.
  • Insertion Lengths: Standard options include 35 mm (1⅜"), 50 mm (2"), and 75 mm (3"). Custom lengths are available upon consultation with Flow Engineering.
  • Output Signals: Options include analog 4 to 20 mA, PNP/NPN transistor output (up to 400 mA), or Relay (SPDT) for the FSW-91-R + FSCN-90 configuration.
  • Visual Indication: Features an 8 LED bargraph for flow rate and setpoint status, plus a di-chromatic switch point status indicator (Red: No flow; Green: Flow).

Key Product Differences

The series distinguishes between integrated transmitters and separate sensor configurations. The FSW-9000 is an enclosed unit with glass-filled nylon or aluminum housing, providing both analog 4 to 20 mA output and PNP/NPN switch output powered by 24 Vdc ±10%. In contrast, the FSW-91-R variant consists of a sensor without an enclosed housing, intended for remote control via separate electronics such as the FSCN-91 relay. The FSCN-91 operates on either DC or AC supply voltage (85 to 240 Vac, 50/60 Hz or 24 Vdc ±10%) and provides analog 4 to 20 mA and SPDT outputs within an ABS enclosure suitable for DIN rail mounting.

Model numbering follows the pattern FSW-9(**)(**)(**) where digits specify process connection, enclosure type, and insertion length. For example, model FSW-9123 denotes a transmitter with ½ NPT thread, aluminum die cast enclosure, and 75 mm (3") insertion length.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-CA
en_CA
Save Configuration