iLD-Series
Large Display Meters & PID Controllers, Color Changing Display
- UL and cUL Certified
- BIG Bright 2.25'(57.2 mm) or 4.00'(101.6 mm) LED Display
- Program to Change Colors: RED, AMBER, GREEN
- Temperature and Process Input Models
iLD-Series
From
C$
2 994.36
Product Overview
- A/D Conversion Dual slope
- Accuracy ± 0.5 °C
- Accuracy Detail ±0.5°C temperature; 0.03% rdg
- Alarm modes Band, High/Low, Latch/Unlatch, Normally Open/Closed, Process/Deviation
- Common Mode Rejection 120 dB
- Control Mode Reverse (heat) or direct (cool)
- Current Measurement Range 0 to 20 mA
- Data Interface Note Ethernet : Standards compliance IEEE 802.3 10Base-T Supported Protocols : TCP/IP, ARP, HTTPGET RS232/RS422/RS485/MODBUS : Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status. RS485 : Screw terminals
- Decimal Selection 0, 0,001, 0,01, 0,1
- Digital Filter Programmable
- Display Color Red, Green, Amber
- Display Size 57.2 mm (2.25 in)
- Display Type 4 Digit, 7 Segment LED
- Display Type Note 4-digit or 6-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
- Electrical Connection Screw Terminal
- Enclosure Ratings IP65, NEMA Type 4
- Excitation Voltage Note Optional in Place of Communication
- Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
- Input Configuration Single-ended
- Input Type Themocouple, RTD, Current, Voltage
- Isolation Power to Input/Output: 2300 Vac per 1 min test (RS232/485, input or output) Between Inputs: 500 Vac per 1 min test
- Normal Mode Rejection 60 dB
- Offset Adjustment -1999 to +9999
- Operating Temperature, Max 40 °C
- Operating Temperature, Min 0 °C
- Polarity Unipolar
- Power Consumption 22.5 W
- Reading Rate 3 samples/sec
- Relative Humidity 90% RH non-condensing
- Resolution 1°/0.1°; 10 µV process
- RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
- Sensor/Transmitter Power 24 Vdc @ 25 mA
- Series ID iLD-Series
- Set Point Adjustment -1999 to 9999 counts
- Span Adjustment 0.001 to 9999 counts, programmable
- Step Response 0.7 sec for 99.9%
- Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz
- Supply Voltage 100 to 240 Vac
- Temperature Stability RTD: 0.04°C/°C;Thermcouple @ 25°C (77°F): 0.05°C/°C—cold junction
- Thermocouple Lead Resistance, Max 100 Ω
- Thermocouple Type J, K, T, E, N, R, S, B, C, L
- Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
- Warm-Up to Rated Accuracy 60 min
Supported Applications
The Omega iLD Series comprises large-display digital panel meters and PID controllers designed for universal temperature monitoring, process measurement, strain gage applications, AC current/voltage sensing, frequency/pulse/rate totalization, and remote display via serial or Ethernet inputs. The series supports thermocouple types J, K, T, E, R, S, B, C, N, L (ITS 90) and RTD sensors (100/500/1000 Ω Pt, ITS 68). Configurable for industrial process control, the units feature programmable color-changing displays that shift between RED, AMBER, and GREEN at set points or alarm conditions.
Operating Conditions & Performance
The iLD Series operates within an ambient temperature range of 0 to 40°C (32 to 104°F) with up to 90% RH non-condensing. A warm-up period of 60 minutes is required for UTP, SP, FP, ACC, and ACV models to achieve rated accuracy. Accuracy specifications vary by input model: Universal Temperature/Process (UTP) offers ±0.5°C temperature or 0.03% reading process; Strain/Process (SP) provides 0.03% reading; Frequency/Pulse (FP) achieves ±0.1% of FS with crystal time-based accuracy of ±50 ppm at 25°C; AC Current (ACC) and AC Voltage (ACV) models specify ±0.2% of FS across their respective frequency ranges.
Response times are documented as a step response of 0.7 sec for 99.9% final value on UTP and SP inputs, while ACC and ACV models respond in 2 s to 99% (filter time constant = 64). FP models with RS485 output achieve 0.1 s to 99%. The reading rate is 3 samples per second across the series.
Configuration Options
The iLD Series offers extensive configuration options for display size, input type, and communication protocols:
- Display Sizes & Digits: Available with 57 mm (2.25") or 101 mm (4") LED digits in either 4-digit or 6-digit configurations.
- Housing & Mounting: Units mount flush in a panel or on the surface using included brackets. The enclosure provides NEMA 4 (IP65) protection for the entire unit, with specific front bezel ratings also noted as NEMA 4 (IP65).
- Input Models:
- UTP: Universal temperature and process inputs including thermocouples, RTDs, voltage (0 to 100 mV, 0 to 1 V, 0 to 10 Vdc), and current (0 to 20 mA).
- SP: Strain gage and process inputs with linearization points up to 10.
- ACC/ACV: Dedicated AC Current ranges (10 mA, 100 mA, 1 A, 5 A) and AC Voltage ranges (400 mV, 4 V, 40 V, 400 V).
- FP: Frequency/Pulse/Rate inputs from 0.2 Hz to 50 KHz with totalize modes.
- Communication Options:
- -C24: Isolated RS232 and RS485/422 output (baud rate 300 to 19.2 kB).
- -EI: Ethernet, RS232, RS485/422 output.
- -C4EI: Ethernet with embedded Web server + RS485/422 hub for up to 31 devices (IEEE 802.3, 10 Base-T).
- Control & Alarms: Optional -33 suffix provides 2 relays form C SPDT 3 A @ 120/240 Vac for UTP and SP models only. Alarm 1 and 2 are programmable with high, low, band, latch/unlatch operations.
- Power Supply: Universal input of 100 to 240 Vac ±10%, 50/60 Hz (22.5 W).
Key Product Differences
The series distinguishes models by display size and digit count, indicated in the model code: "iLD2" denotes a 57 mm (2.25") display while "iLD4" indicates a 101 mm (4") display; the following number specifies digits (e.g., iLD24 is 4-digit, iLD26 is 6-digit). Input functionality varies by suffix: UTP and SP models support relay outputs (-33) and full PID control features including setpoint adjustment from -1999 to 9999 counts. FP, ACC, and ACV models focus on frequency and electrical measurements with standard RS485 output or optional Ethernet/serial configurations (-EI). Remote display variants (C2/EI suffixes) accept serial or network inputs for monitoring without local sensor connections.