Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Class > 0.25%
  • Accuracy Detail ± 0.5% TP; ± 0.40% BFSL includes non-linearity, hysteresis and non-repeatability, zero offset and span setting errors (add 0.05% for ranges above 5000 psi)
  • Additional Features 1 None
  • Compensated Temperature, Max 85 °C
  • Compensated Temperature, Min -20 °C
  • Electrical Output 4 to 20 mA
  • Electrical Output Note 4 to 20 mA(2 wire)
  • Enclosure Material 304 Stainless Steel
  • Enclosure Ratings IP65, NEMA Type 7, NEMA Type 9
  • Fits Cable Diameter 9 to 12 mm
  • Insulation Resistance 100 MΩ
  • Materials, Wetted 316 Stainless Steel
  • Operating Temperature, Max 125 °C
  • Operating Temperature, Min -40 °C
  • Position Effect ± 0.02% typical
  • Process Connection Note 1/2 NPT male conduit fitting and 4.6 m (15') cable with flying lead termination
  • Process Temperature, Max 125 °C
  • Process Temperature, Min -40 °C
  • Protection Reverse polarity and mis-wire protected
  • Relative Humidity 0 to 0.95
  • Response Time 2 ms
  • Series ID PX835
  • Stability ≤± 0.25%
  • Stability Note ≤± 0.25% span/year @ ref conditions (21°C/70°F)
  • Storage Temperature, Max 125 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note 12 to 32 Vdc Vmin=12V+(0.022Ax loop res)
  • Supply Voltage 12 to 32 Vdc
  • Thermal Effect on Span error, Max 2% span
  • Thermal Effect on Zero error, Max 2% span
  • Vibration 100 g peak, 11 ms; Vibration Random: 10 g RMS, 20 to 2000 Hz; Vibration Sweep : 50 to 2000 Hz, 5 g peak
  • Weight 254 g

Supported Applications

The Omega PX835 Series consists of explosion-proof and flame-proof pressure transmitters designed for hazardous industrial locations. Documented applications include oil field equipment, upstream oil and gas production, natural gas compression and transfer control, alternative energy projects, and fuel cell manufacturing.

These intrinsically safe units are suitable for a broad spectrum of sensing requirements, including vacuum, compound, and gage pressure ranges.

Operating Conditions & Performance

The PX835 Series operates within an ambient temperature range of -20 to 85°C (-4 to 185°F) and a process temperature range of -40 to 125°C (-40 to 257°F). Storage temperatures are rated from -40 to 125°C (-40 to 257°F), with humidity tolerance up to 95% RH, non-condensing.

Performance specifications include an accuracy of ±0.5% True Pressure (TP) or ±0.40% Full Scale (BFSL). The response time is 2 ms. Mechanical robustness includes a shock rating of 100 g peak at 11 ms and vibration resistance defined as Sweep: 50 to 2000 Hz, 5 g peak; Random: 10 g RMS, 20 to 2000 Hz.

Pressure ranges span from vacuum/compound configurations (e.g., Vac to 100 psi / -1 to +7 bar) up to high-pressure gage applications of 0 to 10,000 psi (0 to 690 bar). Overpressure ratings are specified as 2 x FS min for ranges from 0/Vac to 300 psi and 1.5 x FS for ranges from 500 to 10,000 psi.

Configuration Options

The series features an all-welded stainless steel case (housing material: 304 SS) with wetted materials consisting of a 316SS diaphragm and pressure port. The standard process connection is a ¼ NPT male fitting, while electrical termination utilizes a ½ NPT male conduit fitting.

Output Signals & Power

  • 4 to 20 mA output (2-wire): Requires power supply of 12 V min / 36 V max. For Intrinsically Safe installations, the maximum supply voltage is limited to 30Vdc.
  • 1-5Vdc output (3-wire voltage output): Requires power supply of 10V min / 30V max.

Hazardous Area Certifications

  • Explosion Proof – cULus: Class I, Div. 1 & 2, Groups A, B, C and D; Class II, Div. 1 & 2, Groups E, F and G.
  • Flame Proof – ATEX (Specify PX835): II 2 GD, Ex d IIC T4, Ex nC IIC T4.
  • Intrinsically Safe (applies to 4-20mA) FM: Class I, Div. 1; Class I, Div. 2, non-incendive.

Options & Accessories

  • Oxygen cleaning: Available by adding suffix “-X6B” to the model number for additional cost.
  • Electrical termination options: Includes 4-pin Bendix style shell size 8 (options B4, H1, L1, P2), pigtail conduit ½ NPT male (C1, P7), flying leads conduit ½ NPT male (C2, C3, C4), and shielded cable.

Key Product Differences

The PX835 Series is configured by pressure range. Model numbers follow the format PX835-GI, where the numeric portion indicates the specific gage or compound range (e.g., PX835-030GI for 0 to 30 psi). The series supports vacuum and compound ranges such as Vac to 15, Vac to 30, up to Vac to 100. Gage pressure variants cover discrete steps from 0 to 5 psi through 0 to 10,000 psi.

Physical dimensions are consistent across the series with a typical overall length of 4.78″ (121 mm) and body diameter of 1.06″ (27 mm). The hex size for all pressure fittings is common at 1.06″ (27).

Accessories

Pressure Snubbers to Protect Against Pressure Surges
From C$27.12
0 In Stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Do these have span and zero pods that can be adjusted?

Asked by: Tc41
Thanks for the inquiry These do not have any type of adjustments we do carry other but they wouldn't have the certifications that these have. .
Answered by: application engineer je
Date published: 2021-06-21

Where are the wiring diagrams and ancillary parts recommended and/or required for approved Intrinsicly Safe installation? The User Guide briefly references "See Omega drawing #825A027", but a search for this term brings up only the User Guide.

Asked by: CDunn
Thank you for your inquiry, this document can be obtained by contacting us at pressure@omega.com.
Answered by: rkent
Date published: 2022-11-02

Do you know what the Performance Level (a-e) of this sensor is?

Asked by: ScottB
Thank you for your inquiry, that information can be found in the manual under hazardous area certification.
Answered by: rkent
Date published: 2022-09-08

Do these carry a GOST or GOST R compliance certification (Russian Metrology)?

Asked by: SDoll
These do not carry that certification, all the certifications that are available with this device are noted in the data sheet link above.
Answered by: PressureENG
Date published: 2020-04-09
  • y_2026, m_8, d_5, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_PX835-005GI, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 48ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration