Need assistance? Call us: 1-800-663-4209
FP7001-Fittings
Installation fitting for FP7002 Series paddle flow meters
Models In Stock
- Dedicated fitting for FP7002 paddle-wheel flow meters ensures secure, accurate insertion
- Adaptable to your piping system with multiple NPT/flange thread sizes and fitting options
- Rated for up to ~150 psi (10.3 bar) and ~93 °C (≈200 °F) process conditions
- Simplifies installation and maintenance of insertion flow meters with minimal downtime
FP7001-Fittings
From
C$
213.19
Models In Stock
Product Overview
- Operating Pressure, Max 150 psi
- Process Temperature, Max 93 °C
- Series ID FP7001-Fittings
Supported Applications
The FP7001 Series consists of installation fittings designed specifically for use with Omega FP7002 Series paddle flow meters. These components facilitate the mechanical integration of the sensor into piping systems.
Operating Conditions & Performance
No specific operating conditions, performance metrics, or environmental limits are documented in the available source data for this series. Technical specifications regarding pressure ratings, temperature ranges, and media compatibility must be verified against the associated FP7002 Series paddle flow meter documentation.
Configuration Options
The series is offered as a set of discrete installation fittings identified by specific part numbers. The available variants include:
- FP7007
- FP7010
- FP7012
- FP7015
- FP7020
- FP7025
- FP7030
In addition to the standard configurations, variants with a "-GI" suffix are available for each model number (e.g., FP7007-GI, FP7010-GI).
Key Product Differences
The primary distinction within the series is defined by the part number and the presence of the "-GI" designation. The bundle lists 14 total variants corresponding to seven base models (FP7007 through FP7030) with both standard and -GI configurations enabled.
Show Ratings & Reviews
I'm using this fitting (FP7010) with a FP7001A Paddle wheel Flow & Temperature Sensor (FP7001A). Where do I find the K- Factor (Pulses/Gallon)? I did not see it specified in either user manual...
Thank you for your inquiry. The K-factors can be found in the FP7001A datasheet. The K-Factor for the FP7010 fitting is 70.53 pulses per gallon.
Date published: 2020-11-10
Is this a "Tee" fitting with two FNPT ports or a Bushing that goes into a FNPT port.
FP7010-GI is a T fitting with FNPT on both sides.