Need assistance? Call us: 1-800-663-4209
Series-CDTA
Indoor Air Quality CO2 Detectors with Humidity & Temp Sensors, Easy Install
Models In Stock
- Minimize inventory and save time by combining CO2, RH and temperaturemeasurements into one transmitter
- Reduce installation time with field selectable Modbus and BACnet communications
- Reduces the number of devices mounted in the space with integral humidity andtemperature sensors
- Requires minimal maintenance with Automatic Baseline Correction (ABC) to accountfor sensor drift
- Prevent tampering with physical hardware lockout
- Easily installation with optional remote display tool and simple installation withbackplate electrical connection
Series-CDTA
From
C$
591.23
Models In Stock
Product Overview
- Carbon Dioxide Accuracy ± 40 PPM + 3% rdg
- Carbon Dioxide Concentration, Min 0 ppm
- Carbon Dioxide Response Time 120 s (τ90)
- Data Interface Modbus RTU, BACnet MS/TP
- Measurement Type Carbon Dioxide, Humidity, Temperature
- Mounting Orientation North American Style Wall Mount
- Operating Temperature, Max 122 °F
- Operating Temperature, Min 32 °F
- Relative Humidity 0 to 85% RH Non-Condensing
- Relative Humidity Accuracy ± 2% RH
- Relative Humidity Input Range 0 to 100% RH
- Sensor Life 15 Years
- Sensor Type CO2: NDIR; Humidity: Capacitive Polymer; Temp: Diode
- Series ID Series-CDTA
- Supply Power Type AC/DC
- Supply Voltage 10 to 30 Vac/10 to 42 Vdc
- Switch Type N/A
- Temperature Accuracy ± 1 °C
- Temperature Output Range N/A
- Weight 4.4 oz
Supported Applications
The Series CDTA Communicating Carbon Dioxide Detector combines the function of several room sensors into a single, compact housing. Each unit measures carbon dioxide, temperature, and temperature set point with override, and the CDTA additionally includes a humidity sensor, making it an all-in-one CO2/RH/temperature/set-point device for indoor air quality management.
Because communication is field-selectable between Modbus® and BACnet, the detectors can be daisy chained with only four wires for both power and communication signal, which simplifies wiring in demand-controlled ventilation and building-automation retrofits. Install away from locations with severe shock or vibration, excessive moisture, or corrosive fumes, and disconnect the power supply before installation to prevent electrical shock and equipment damage.
Operating Conditions & Performance
The CO2 sensor measures either 0 to 2000 or 0 to 5000 PPM depending on model, the humidity sensor covers 0 to 100% RH, and the temperature channel measures across 0 to 50°C.
- CO2 accuracy: ±40 PPM ±3% of reading on the 2000 PPM model and ±50 PPM ±5% of reading on the 5000 PPM model.
- RH accuracy: ±2% (10 to 90% RH).
- Temperature accuracy: ±1°C at 25°C.
- Response time: 2 minutes.
- Power requirements: 10-42 VDC / 10-30 VAC, with a 1/8 unit device load.
- Output: 2-wire RS-485, Modbus® RTU or BACnet MS/TP communication protocol.
Sensing elements are an NDIR CO2 sensor with a 15 year life expectancy, a capacitive polymer humidity sensor, and a 10KΩ thermistor for temperature. The device operates from 0 to 50°C with a humidity limit of 0 to 85% (non-condensing). It measures 114.30 mm high by 71.12 mm wide by 27.69 mm deep and weighs 4.4 oz (125 g). A 120Ω terminating resistor can be switched in between A[-] and B[+]. Agency approvals are BTL and CE.
Configuration Options
All models share the same communicating platform, four-wire daisy-chain wiring, and set-point-with-override capability; they differ by CO2 measuring range, display option, and the humidity feature of the CDTA line.
- CO2 range: models are offered for either a 0 to 2000 PPM or a 0 to 5000 PPM span.
- Display: an on-board LCD version is available to show any of the measured parameters, and optional local and remote displays are also offered.
- Set point range: the temperature set point is field adjustable, defaulting to 20°C for the low limit and 35°C for the high limit and spanning from 0°C up to 50°C.
Key Product Differences
The lineup pairs each CO2 range with a display option:
- CDTA-2N000 — 2000 PPM CO2 detector without display.
- CDTA-2N000-LCD — 2000 PPM CO2 detector with LCD.
- CDTA-5N000 — 5000 PPM CO2 detector without display.
- CDTA-5N000-LCD — 5000 PPM CO2 detector with LCD.
PDFs & Manuals
Accessories
accessories
Gas calibration kit with 200 ppm CO and 2000 ppm CO2 gas for field calibration (ground shipment only).
C$1,199.75 / each
1 In Stock
meters/controllers
Show Ratings & Reviews