Need assistance? Call us: 1-800-663-4209
OM-CP-ULTRASHOCK-Series
Humidity, Temperature, Pressure and Tri-Axial Shock Data Logger Part
- Built-In Accelerometers
- All Inclusive Design
- Compact
- Programmable Start Time
OM-CP-ULTRASHOCK-Series
From
C$
1,540.39
Product Overview
- Acceleration Range ± 5 g
- Accelerometer Sensor Type MEMS
- Accuracy Detail Calibration Accuracy : Humidity : ±3 %RH (±2 %RH typical at 25 °C), Pressure : ±1.0% FSR 25°C; ±0.2% typical, Temperature : ±0.5°C (0 to 50°C); Time Accuracy : ±1 min per month at 2 to 30°C
- Approvals CE
- Battery life up to 170 hr
- Battery Size and Type Alkaline 9V
- Baud Rate 115200
- Calibration Digital calibration through software and automatically recorded within device
- Calibration Accuracy Humidity : ±3% RH, Temperature : ±0.5 °C, Pressure : ±1%, Accelerometer : ±0.2 g
- Data Interface USB
- Data protection Access by password
- Frequency Response 0 to 400 Hz
- Height 111 mm
- Humidity Range 0 to 95% RH non-condensing
- Length 89 mm
- Materials Aluminum
- Measuring Temperature Range, Max 60 °C
- Measuring Temperature Range, Min -20 °C
- Memory 174,762 Readings
- Millivolt Range N/A
- Number of Measurements 6
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Measurement Pressure, Max 0 psi
- Pressure Sensor Type Silicon Strain Gage
- Measurement Pressure Type Absolute
- Process Connection Size 1/4 in
- Process Connection Type N/A
- Real Time Recording Device can be used with PC to monitor and record instantaneous measurements in real-time
- Relative Humidity Sensor Type Capacitive Polymer
- Resolution Pressure : 0.002 psi, Humidity : 0.1% RH, Temperature : 0.1°C, Acceleration : 0.01 g
- Sampling Rate 1.953 msec
- Sampling Rate Note 1.953 ms/512 Hz 64 Hz to 5 minutes for shock, selectable in software. Temperature, pressure and humidity sampled approximately every 2 seconds at intervals shorter than 2 seconds. Otherwise, sampled at the reading rate.
- Series ID OM-CP-ULTRASHOCK-Series
- Software Windows XP SP3 / Vista / 7 and 8 (32 and 64 - bit)
- Start Modes Delayed Start, Immediate Start
- Supply Power Type Battery
- Temperature Sensor Type Silicon Diode
- Time Accuracy ±1 minute/month
- Weight 341 g
- Width 26 mm
Supported Applications
The Omega OM-CP-ULTRASHOCK series is a battery-powered, stand-alone data logger designed to measure and record temperature, pressure, humidity, and tri-axial shock. Part of the NOMAD® family, these devices are engineered for documenting dynamic environments in moving vehicles, trucks, containers, and ships. The series supports characterizing environments within production and assembly lines handling delicate electronics, IC fabrication, communications equipment, and computer components.
Operating Conditions & Performance
The OM-CP-ULTRASHOCK operates across an ambient temperature range of -20 to 60°C (-4 to 140°F) with a humidity rating of 0 to 95% RH non-condensing. The device features solid-state memory capable of storing up to 174,762 readings per channel and supports sampling rates from 64 Hz down to one reading every 5 minutes for shock events.
Performance specifications by measurement type include:
- Temperature: Semiconductor sensor with a range of -20 to 60°C (-4 to 140°F), resolution of 0.1°C, and accuracy of ±0.5°C (0 to 50°C).
- Humidity: Capacitive Polymer sensor ranging from 0 to 95% RH with a resolution of 0.1% RH and an accuracy of ±3% RH (±2% RH typical at 25°C). Specified accuracy applies within the range of 10 to 40°C; 10 to 80% RH.
- Pressure: Semiconductor strain gage sensor measuring 0 to 30 psia with a resolution of 0.002 psia and calibrated accuracy of ±1.0% FSR at 25°C (±0.2% typical).
- Shock: MEMS Semiconductor accelerometer available in ranges of ±5 g, ±50 g, ±100 g, or ±250 g. Accuracy varies by range: ±0.2 g for the ±5 g range; ±1 g for the ±50 g range; ±2 g for the ±100 g range; and ±4 g for the ±250 g range.
The device supports a sampling rate of 1.953 milliseconds (512 Hz) with an acceleration frequency response from 0 Hz to approximately 400 Hz. Time accuracy is rated at ±1 min per month at 2 to 30°C, and battery life typically ranges from 3 to 7 days using a lithium battery at a 1-minute reading rate.
Configuration Options
The series offers configurable shock measurement ranges and optional calibration documentation. The housing is constructed of anodized aluminum with overall dimensions of 89 H x 111 W x 26 mm D (3.5 x 4.4 x 1.0") and a weight of 341 g (12 oz).
Key configuration options include:
- Shock Ranges: Models are available in ±5 g, ±50 g, ±100 g, or ±250 g configurations.
- Calibration Certification: Variants with the "-CERT" suffix include a NIST calibration certificate. Calibration dates are automatically recorded within the device.
- Data Interface: Data retrieval is supported via USB or COM port (interface cable required) at 115,200 baud. The OM-CP-IFC200 interface includes Windows software and a 1.8 m (6') USB cable.
- Software & Validation: Software supports XP SP3/Vista/7 and 8 (32-bit and 64-bit). An optional FDA 21 CFR part 11 compliant IQ/OQ/PQ secure software validation workbook is available as the OM-CP-SVP-SYSTEM.
- Power & Mounting: Powered by a user-replaceable 9V lithium or alkaline battery (included). A magnet mount kit (OM-CP-SHOCK-MAG-KIT) and replacement batteries (OM-CP-BAT103) are offered as accessories.
Data formats include date/time stamps with units selectable for gravities, temperature (°C, °F, K, °R), humidity (%RH, mg/ml water vapor concentration), and pressure (psia, inHg, mm Hg, bar, atm, torr, Pa, kPa, MPa). The device supports immediate start or delay start up to 6 months in advance.
Key Product Differences
The OM-CP-ULTRASHOCK series distinguishes models primarily by shock measurement range and the inclusion of calibration documentation. Standard model numbers follow the pattern OM-CP-ULTRASHOCK-<g-range>, while certified versions append "-CERT" (e.g., OM-CP-ULTRASHOCK-50-CERT). All models share identical temperature, humidity, and pressure sensor specifications but differ in their accelerometer range selection.
PDFs & Manuals
Software & Drivers
Accessories
cables
consumables
Show Ratings & Reviews
does this unit come with patch cord? I didn't see one to connect to my computer.
Hello Chris
The usb cable/software pack is sold separately, part number is OM-CP-IFC200.
Date published: 2020-04-24