KHXL-NHXL

High Temp Low Drift Handheld Thermocouple Probes

Models In Stock
  • Super Accurate, Super Stable, Super Value
  • For Use Up to 1335°C (2440°F)
  • Excellent Long Term Stability at High Temperatures
  • Low Thermal Drift
KHXL-NHXL
From C$ 86.43
Models In Stock
High Temp Low Drift Handheld Thermocouple Probes KHXL-NHXL KHXL-NHXL
loading all models
Product Overview
  • Electrical Connection Miniature Male Thermocouple Connector
  • Probe Type Utility Handle Probes
  • Process Connection Direct, Compression Fitting
  • Process Temperature, Min 0 °C
  • Series ID KHXL-NHXL
  • Sheath Material Dual Wall XL
  • Temperature Probe Style Utility Handle Probe
  • Temperature Sensor Type Thermocouple

Supported Applications

The Omega KHXL and NHXL series comprises Super OMEGACLAD® XL thermocouple probes designed for high-temperature measurement in harsh environments. These mineral-insulated (MI) handheld probes are engineered to resist carburization, oxidation, and chlorination. The series supports Type K (CHROMEGA®-ALOMEGA®) and Type N (OMEGA-P®-OMEGA-N®) calibrations.

Operating Conditions & Performance

The probes operate in process temperatures up to 1335°C (2400°F). Accuracy meets or exceeds SLE and EN 60584-2 Tolerance Class 1 standards. Long-term stability is documented as less than 2.8°C drift in 25 weeks.

Response time varies by sheath diameter for ungrounded probes tested in water:

  • 0.3 sec** for 0.032" Dia. probe
  • 0.55 sec** for 0.125" Dia. probe
  • 2.25 sec** for 0.250" Dia. probe

Note: Tests were conducted using ungrounded probes in an open-air, electric muffle furnace versus a Type 'S', NIST-traceable standard.

Configuration Options

The series offers extensive configuration options across probe styles, dimensions, and junction types to accommodate specific installation needs.

  • Probe Styles: Quick-connect (molded), miniature connector, heavy-duty transition junction, industrial head assemblies, and utility handle probes.
  • Junction Types: Grounded (G) or ungrounded (U). Some configurations include exposed options depending on the specific model series.
  • Diameters: Available in standard inch sizes from 0.010" to 3/8", and metric sizes including 0.25 mm, 0.5 mm, 0.75 mm, 1.0 mm, 1.5 mm, 3.0 mm, 4.5 mm, 6.0 mm, 8.0 mm, and 9.5 mm.
  • Lengths: Standard lengths include 6", 12", 18", and 24" (inch series) or 150 mm, 300 mm, 450 mm, and 600 mm (metric series). Custom insertion lengths are available via ordering codes.
  • Sheath Materials: CHROMEGA®-ALOMEGA® XL Sheath for Type K; OMEGA-P®-OMEGA-N® XL Sheath for Type N.

Additional options include dual-element configurations and PFA coating (consult sales). A universal connector and cable clamp are included with the probes. Replacement probes are available for industrial head assemblies by adding '-RP' to the part number.

Key Product Differences

The series is divided into two primary alloy families based on thermocouple type:

  • KHXL Series (Type K): Utilizes CHROMEGA®-ALOMEGA® XL Sheath. Model numbers begin with 'K' or include the ANSI color code for Type K.
  • NHXL Series (Type N): Utilizes OMEGA-P®-OMEGA-N® XL Sheath. Model numbers begin with 'N' or include the ANSI color code for Type N.

Variations also exist by connector style and housing:

  • Quick-Connect Probes (KQXL/NQXL): Feature molded standard connectors. Miniature versions are designated with 'M' in the model number (e.g., KMQXL).
  • Transition Junction Probes (TJ36/KMTXL/NMTXL): Designed for heavy-duty transition junctions or miniature transition junction probes.
  • Industrial Head Assemblies: Feature replaceable probe elements. Model numbers typically include 'NB' prefixes in the ordering guide context, with replacement parts ordered by adding '-RP'. Smaller-sized probes are supplied with stainless steel transition joints and stripped leads as standard.
  • Utility Handle Probes (KHXL/NHXL): Designed for handheld use with a utility handle configuration. Model numbers include the 'RSC' suffix in many variants to denote specific connector or assembly configurations.
Rated 1 out of 5 by from Poor quality product Worked for less than a year then stopped. Was used 2-3 times x week measuring hot water and then stored dry. for the price we paid we are very dissastisfied with the longevity of the product.
Date published: 2025-01-27
Rated 4 out of 5 by from Great product, took forever to ship! Product works incredibly well but be wary of freight/shipping times. Ordered mid-July, called beginning of August to get an ETA and they said end of August. Didn't actually ship till I called again mid-September and arrived the following week. Other than that, great product.
Date published: 2021-10-14
  • y_2026, m_8, d_3, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_KHXL-116E-RSC-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT

Can this probe be cut to a shorter length?

Asked by: Kyle72
Thank you for your inquiry. Unfortunately, no, it cannot be cut to a shorter length.
Answered by: NorwalkAE_SP
Date published: 2024-05-31

Hello, does this product work in direct contact with molten metals up to the 2400F, or is there some sort of sleeve you might recommend in addition to this T/C?

Asked by: Turbo LS1 GTO
Thank you for your inquiry. This product is not suited for multiple uses in molten metal applications.
Answered by: Application Engineer CB
Date published: 2023-08-22

Is this product food safe?

Asked by: Zukken
Hi, this thermocouple probe is made from a high temperature metal which can go to 2400F but is not specifically rated for food applications or sanitary. We do have this probe which can be used with frozen foods: https://www.omega.com/en-us/sensors-and-sensing-equipment/temperature/sensors/thermocouple-probes/p/88312-SPECIAL-TC-PROBE Please email temp@omega.com if you need any further assistance.
Answered by: Jane
Date published: 2023-03-15
  • y_2026, m_8, d_2, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_KHXL-116E-RSC-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration