LCWD
High Accuracy, Load Washers to Measure Bolt Compression
Models In Stock
- Ranges to 200,000 lb
- Compact Design
- Spherical Washers Included
- Load Buttons Included
LCWD
From
C$
1,011.03
Models In Stock
Product Overview
- Cable Length 5 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Force Type Compression
- Full Scale Deflection 0.001 in
- Load Cell Type Load Washer
- Materials Stainless Steel
- Operating Temperature, Max 127 °C
- Operating Temperature, Min -40 °C
- Overload, Max 200% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Safe Overload 120% FS
- Series ID LCWD
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.018% FSO/°C
- Thermal Zero Effect ± 0.018% FSO/°C
- Wiring/Connector Table Red: (+) Excitation; Black: (-) Excitation; Green: (+) Output; White: (-) Output
- Zero/Balance Error ± 4%
Supported Applications
The Omega LCWD Series consists of compact load washers and compression load cells designed to measure bolt compressional forces. Typical applications documented for the series include clamping forces, die loads, bolt stresses, weighing systems, and structural loads.
Operating Conditions & Performance
The LCWD series features a full Wheatstone bridge construction with stainless steel housing. Measurement ranges span from 0 to 200 lb up to 0 to 200,000 lb (and metric equivalents of 1 kN to 200 kN). Accuracy is specified as ±0.5% BFSL for capacities ≤10K lb/50 kN and ±0.75% BFSL for capacities >10K lb/50 kN, combining linearity, hysteresis, and repeatability.
Electrical specifications include an excitation voltage of 10 Vdc (15V maximum) with a bridge resistance of 350 Ω minimum for units <50K lb/200 kN and 700 Ω for ≥50K lb/200 kN. Output signals are nominal at 1 mV/V for capacities <500 lb/2kN and 2 mV/V ± 20% for ≥500 lb/2kN.
Temperature performance is defined by a compensated range of 16 to 71°C (60 to 160°F) and an operating temperature range extending from -40 to 127°C (-40 to 260°F). Thermal effects are rated at ±0.01% FSO/°F for both zero and span. The series supports a safe overload of 120% of capacity and an ultimate overload of 200% of capacity.
Configuration Options
The LCWD series is available in standard (LCWD) and metric (LCMWD) model configurations. Each unit includes a set of spherical washers and load buttons to ensure correct loading alignment when used as a washer or compression cell. The electrical connection consists of a 5 ft (1.5 m) PFA insulated, shielded cable.
Key configurable dimensions vary by capacity:
- Bore Sizes: Range from 0.40 in (10 mm) for lower capacities up to 1.51 in (39 mm) for the 200,000 lb model.
- Outer Diameters: Scale from 1.00 in (25 mm) to 3.00 in (77 mm).
- Height (H): Varies between 9.0 mm (0.35 in) and 32 mm (1.25 in) depending on the rated capacity.
The series supports NIST traceable calibration, with units supplied complete with either a 4-point or 5-point NIST-traceable calibration certificate and shunt data. Compatible signal conditioners include the iDRX-ST (digital output with RS485) and iDRN-ST (analog output).
Key Product Differences
The series distinguishes between standard inch-based models (LCWD-<Capacity>) and metric models (LCMWD-<Capacity>). Standard model capacities include 200, 500, 1K, 2K, 5K, 10K, 20K, 50K, 100K, and 200K lb. Metric models cover ranges from 1KN to 200KN.
Dimensional variations are tied directly to the rated capacity; for example, capacities ≤10K lb share a bore of 10.2 mm (0.40 in) and height of 9.0 mm (0.35 in), while higher capacities such as 200K lb require larger dimensions including a 38.4 mm (1.51 in) bore and 32 mm (1.25 in) height.
Output signal magnitude varies by capacity threshold: units rated below 500 lb/2kN provide a nominal output of 1 mV/V, whereas those at or above this threshold deliver 2 mV/V ± 20%. Bridge resistance also shifts based on the load rating, with lower capacities utilizing 350 Ω and higher capacities (≥50K lb) utilizing 700 Ω.
Show Ratings & Reviews
Rated 5 out of
5
by
Melyssa Mogdans from
LCWD-5K
Easy process to place orders and fulfilment was also great!
Date published: 2025-06-27
Rated 5 out of
5
by
Mike V from
Quick Response
Needed this item quickly for product testing. Was able to have it overnighted and worked perfectly.
Date published: 2023-02-17
What do i need record data from this load cell Item# LCWD-100K
You could use either a DP8EPT Display to visually read the force load and communicate with a computer via USB to collect the data or you can use our OM-CP-BRIDGE101A data logger (no display) to collect data via USB to a computer.
Date published: 2021-09-09
Are the LCWD load cells certified or can they be purchased with certification?
The LCWD load cells are shipped with a NIST traceable calibration report included
Date published: 2024-06-10
When I setup theHigh Accuracy, Load Washers to Measure Bolt Compression with the DP8EPT display, I cannot Tare/ Zero with the display?
Thank you for your inquiry, the tare function must be enabled through the menu on the DP8EPT please consult the manual for instructions.
Date published: 2022-09-21
How do I prevent the load cell from rotating when torqueing a bolt against the cell?
Bobby, once the load cells are mounted in place, it is suggested that you use hardened washers both on the top and bottom of the load cell while torqueing your bolt.
Date published: 2023-09-07
Is the STRAIN GAGE/BRIDGE TRANSDUCER-SIGNAL CONDITIONERS required for a purchase of the High Accuracy, Load Washers to Measure Bolt Compression + DP8EPT display?
Thank you for your inquire
No need to go with a signal conditioner unless you are in need to change the signal for the distance?
most load cell can go as far as 50 feet.
Any distance longer you would need to change the loadcell signal to a current or voltage.
Date published: 2022-07-11
Do I need to buy the custom meter, or can I read this device with an existing standard voltmeter or ADC?
You can use a precise digital to measure the 0 to 20mVDC output signal and then calculate the applied load is. We suggest using one of our DP8EPT displays. It will supply the required 10VDC power to the cell and you will be able scale the display to read directly in units of force.
Date published: 2022-05-17
On the LCWD Load cell, can I use a 5 VDC excitation instead of 10 VDC?
Yes you can. The only difference would be the output signal would be 50% lower
Date published: 2023-11-14