Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

TX400-Srs-RFID-Prog-Tx

Head Mount Temperature Transmitters with RFID Communications

Models In Stock
TX400-Srs-RFID-Prog-Tx
From C$ 96.50
Models In Stock
Head Mount Temperature Transmitters with RFID Communications TX400-Srs-RFID-Prog-Tx TX400-Srs-RFID-Prog-Tx
loading all models
Product Overview
  • Approvals CE,EN 61000-6-4, EN 61000-6-2
  • Calibration Wireless with RFID technology (NFC)
  • Diameter 45 mm
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Enclosure Ratings IP20, NEMA Type 1
  • Height 23 mm
  • Housing Material Nylon (PA66)
  • Humidity Range 30 to 90% RH non condensing
  • Lead Resistance, Max 20 Ω
  • Mounting DIN/B Head
  • Noise Rejection 50 to 60 Hz
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Probe Length 0 mm
  • Programmable Functions offset, Range, Sampling Frequency, Sensor Burnout Indication, sensor type
  • Protection Current 30 mA
  • Resolution 1 μA
  • Response Time 600 ms
  • Sampling Time 300 ms
  • Sensor Type Transmitter
  • Series ID TX400-Srs-RFID-Prog-Tx
  • Setup Controls Wireless with RFID technology (NFC)
  • Sheath Material N/A
  • Software Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit)
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -40 °C
  • Supply Power Note 2-wire loop powered; operating range 6 to 32 Vdc
  • Supply Power Type DC
  • Supply Voltage 6 to 32 Vdc
  • Temperature Input Range Pt100: -200 to 800 °C; Pt1000: -200 to 800 °C; Ni100: -50 to 170 °C
  • Transmission Error, Max 0.1% or 0.2°C
  • Weight 30 g

Supported Applications

The Omega TX400 Series comprises miniature head mount temperature transmitters designed to transform signals from RTD or thermocouple sensors into a linearized, 2-wire loop-powered output. The series includes the TX401 and TX402 models, which feature user-configurable settings via an RFID (NFC) programmer and software. These devices incorporate non-volatile memory for data logging with user-selectable sampling time.

Operating Conditions & Performance

The transmitters operate within an ambient temperature range of -40 to 85°C (-40 to 185°F) at 30 to 90% RH (non-condensing). Storage conditions are rated for -40 to 85°C (-40 to 185°F). The enclosure carries a NEMA 1 (IP20) rating according to CE, EN 61000-6-4, and EN 61000-6-2. Performance specifications include a maximum transmission error of 0.1% FS or 0.2°C whichever is greater, with a resolution of 1 µA and a response time of 600 msec (10 to 90%).

Measurement ranges vary by model and sensor type:

  • TX401 RTD Inputs: -200 to 800°C (-328 to 1472°F) for Pt100 (2, 3, or 4-wire); -200 to 600°C (-328 to 1112°F) for Pt1000 (2, 3, or 4-wire); -50 to 170°C (-58 to 338°F) for Ni100 (2, 3, or 4-wire).
  • TX402 RTD Inputs: -200 to 600°C (-328 to 1112°F) for Pt1000 (2, 3, or 4-wire); -50 to 170°C (-58 to 338°F) for Ni100 (2, 3, or 4-wire).
  • TX402 Thermocouple Inputs: Type J: -260 to 1200°C (-328 to 2192°F); Type K: -260 to 1360°C (-436 to 2480°F); Type T: -260 to 400°C (-436 to 752°F); Type E: -260 to 940°C (-436 to 1724°F); Type R/S: -40 to 1760°C (-40 to 3200°F); Type B: 40 to 1820°C (104 to 3308°F); Type N: -260 to 1280°C (-436 to 2336°F).
  • TX402 mV Input: -10 to 70 mV.

Configuration Options

The TX400 Series is configured for specific sensor inputs and output requirements. The housing material is Nylon (PA66), with overall dimensions of 23 H x 45 mm dia (0.9 x 1.77"). Electrical connections utilize screw terminals, and the unit weighs approximately 30 g (1.05 oz).

Key configurable capabilities include:

  • Sensor Inputs: RTD (Pt100, Pt1000, Ni100) in 2-, 3-, or 4-wire configurations; Thermocouples (Types J, K, T, E, R, S, B, N); and mV inputs.
  • Output Signal: 4 to 20 mA loop-powered output with high accuracy via 16-bit conversion.
  • Power Supply: 2-wire loop powered; operating range 6 to 32 Vdc.
  • Configuration & Data Logging: Settings are adjusted using the TX400-RFID programmer and free downloadable RF Programmer Configuration Software. The transmitter supports data logging with user-selectable sampling time stored in non-volatile memory.

Key Product Differences

The series consists of two primary models distinguished by their input capabilities:

  • TX401: An RTD input head mount RFID temperature transmitter. It accepts Pt100, Pt1000, or Ni100 inputs.
  • TX402: A thermocouple/RTD input head mount RFID temperature transmitter. In addition to supporting the same RTD types as the TX401 (Pt100 and Ni100), it accepts Types J, K, T, E, R, S, B, N thermocouples and mV inputs.

Both models are supplied with a 2 YEAR WARRANTY and carry CE, UL, and RoHS certifications. The TX400-RFID programmer is available as an accessory to configure the transmitters.

Rated 4 out of 5 by from Good solution Works as intended. Must have TX400-RFID to configure.
Date published: 2023-07-27
Rated 5 out of 5 by from Miniature Head Mount Temperature Transmitters Product is great ... just a bit slow in getting it here.
Date published: 2022-08-26
Rated 5 out of 5 by from TX401 They work, simple to Program using the nfc programmer. My go to for any rtd to 4-20 mA conversion.
Date published: 2022-03-26
Rated 5 out of 5 by from Replacement part. Replacement part. No issues with the transmitter.
Date published: 2021-04-26
  • y_2026, m_8, d_11, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_TX401, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

What is default 4-20 mA output Temperature range/scale for 100 Ohm RTD?

Asked by: Safron
Hi Safron, Thank you for the inquiry. Please forward this request to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-05-06

Does this product include cold junction compensation?

Asked by: Catherine
Thank you for your inquiry. Model TX401 only accepts RTD inputs. Model TX402 accepts both RTD and thermocouple inputs and has built in cold junction compensation.
Answered by: Application Engineer JB
Date published: 2024-06-07

In the specifications there is a link to the Play Store Android app for Omega’s “Direct Link” software that allows you to configure the TX40x with your smartphone.  The link is broken and the app cannot be found in the store.  Is there a replacement?  

Asked by: JMach
Hi JMach, Sorry to hear of the difficulty. Please forward this question to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-07-29

What is the maximum allowable load resistance in the 4-20 mA loop? Is there a formula for computing this maximum resistance?

Asked by: Gerson
It would be dependent on your supply Voltage but here are the equations to calculate - MAX impedance of input where you connect transmitter 0-20 mA depends on supply voltage, Formula is: Zmax =((VCC – VCCmin) / 0.021) VCC = supply voltage for the transmitter VCC min = 8 VOLT (MINIMUM operating voltage of transmitter 6V + 2V safety margin) 0.021 = max Ampere value obtainable from transmitter for anomaly notice At operating voltage 24V_VCC >> Zmax = approx 750ohm
Answered by: ANBENG
Date published: 2019-11-06
  • y_2026, m_8, d_12, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_TX401, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 45ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration