  • Rugged aluminum case protects instrument from damage during transport/use
  • Large, easy to read LCD and simple operation
  • FM approved to be intrinsically safe in hazardous locations, Class 1, Div 2, Groups A, B, C, D, T4 Ta = 70°C
Series-475
From C$ 367.03
Models In Stock
Handheld Digital Manometer for Air/Gas Pressure, 1 inH2O to 150 psid Series-475 Series-475
loading all models
Product Overview
  • Accuracy ± 0.5 %
  • Accuracy Detail ± 0.5% FS, 60 to 78°F (15.6 to 25.6°C); ± 1.5% FS from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C)
  • Battery Size and Type Alkaline 9V
  • Compensated Temperature, Max 104 °F
  • Compensated Temperature, Min 32 °F
  • Compliance Note CE, FM approved to Class I, Div 2, Groups A, B, C, D, T4 Ta = 70°C
  • Display Note 0.42˝ (10.6 mm) 4 digit LCD
  • Display Type LCD
  • Hysteresis ± 0.1%
  • Materials, Wetted Consult Factory
  • Measurement Type Pressure
  • Media Compatibility Clean dry air / inert gas, Fuel gases, HVAC / room air, Inert / non-reactive gases, Compatible Gases, Methane, Nitrogen, Propane
  • Number of Digits 4
  • Operating Temperature, Max 140 °F
  • Operating Temperature, Min 0 °F
  • Measurement Pressure, Min 0 psi
  • Series ID Series-475
  • Storage Temperature, Max 176 °F
  • Storage Temperature, Min -4 °F
  • Supply Power Type Battery
  • Weight 10.8 oz

Supported Applications

The Series 475 is an Intrinsically Safe Handheld Digital Manometer that measures positive, negative or differential pressures of air and compatible combustible gases, in ranges from 1 in w.c. to 150 psid. Dual push pads on the front panel control on/off, auto zero and pressure-unit selection, so operation is simple with no set-up required.

  • Portable field pressure measurement of air and compatible gases
  • Differential, positive and negative (gauge) pressure checks
  • Air velocity measurement when used with a Dwyer Pitot tube and the -AV kit

The manometer is FM approved to be intrinsically safe in hazardous locations, Class I, Div 2, Groups A, B, C, D, T4 Ta = 70°C, and is CE compliant. It is built in a rugged aluminum case and reads out on a 4-digit LCD with 0.42" (10.6 mm) digits.

Operating Conditions & Performance

Accuracy is ±0.5% FS from 60 to 78°F (15.6 to 25.6°C), and ±1.5% FS across the wider bands of 32 to 60°F and 78 to 104°F. Pressure hysteresis is ±0.1% FS.

  • Operating temperature: 0 to 140°F (-17.8 to 60°C).
  • Compensated temperature range: 32 to 104°F (0 to 40°C).
  • Storage temperature: -4 to 176°F (-20 to 80°C).
  • Power: 9 V alkaline battery, installed non-functional and user replaceable.
  • Weight: 10.8 oz (306 g).

Process connections are two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing, plus two compression fittings for 1/8" (3.18 mm) ID x 1/4" (6.35 mm) OD tubing on the 475-7 and 475-8 only. Wetted materials are consult factory.

Configuration Options

Models differ by pressure range and by the maximum pressure the sensor can tolerate, letting the same handheld platform cover low inches-of-water-column readings up through high-psi work. Higher-range models add compression fittings for their higher working pressures.

  • Inches-water-column models (475-000 through 475-3) cover 0 to 1.000 in w.c. up to 0 to 200.0 in w.c., with maximum pressures from 5 psig to 30 psig.
  • PSI models (475-4 through 475-8) cover 0 to 10.00 psi up to 0 to 150.0 psi, with maximum pressures from 30 psig to 200 psig.
  • -AV air velocity kit adds static pressure tips (A-303), a pitot tube, an A-397 step drill and an A-532 air velocity slide chart for velocity measurement.
  • -NIST adds a NIST traceable calibration certificate.

Accessories include the A-402A tough gray nylon carrying case and the A-47X-BOOT protective magnetic rubber boot.

Key Product Differences

The model number is 475-<range>-FM. The range models and their maximum pressures are:

  • 475-000-FM — 0 to 1.000 in w.c.; max 5 psig.
  • 475-00-FM — 0 to 4.000 in w.c.; max 5 psig.
  • 475-0-FM — 0 to 10.00 in w.c.; max 5 psig.
  • 475-1-FM — 0 to 20.00 in w.c.; max 10 psig.
  • 475-2-FM — 0 to 40.00 in w.c.; max 10 psig.
  • 475-3-FM — 0 to 200.0 in w.c.; max 30 psig.
  • 475-4-FM — 0 to 10.00 psi; max 30 psig.
  • 475-5-FM — 0 to 20.00 psi; max 60 psig.
  • 475-6-FM — 0 to 30.00 psi; max 60 psig.
  • 475-7-FM — 0 to 100.0 psi; max 150 psig.
  • 475-8-FM — 0 to 150.0 psi; max 200 psig.

The -AV air velocity kit is offered on several ranges (for example 475-0-FM-AV, 475-00-FM-AV and 475-1-FM-AV).

Accessories

accessories

Rubber latex tubing has less tendency to kink in storage and occupies less space, thus is best for portable work. 3/16" ID, 9' length.
C$16.24 / each
2178 In Stock
Portable static pressure tip, for 3/16" ID rubber or plastic tubing with 4" insertion.
C$20.66 / each
687 In Stock
Rugged step drill, quickly provides true round holes in thin materials, no center punch needed to start, automatically de-burrs drilled hole, high speed steel, drills 3/16" through 1/2" holes in 1/16" increments.
C$113.72 / each
214 In Stock
Carrying case for most manometers; tough, gray nylon pouch, double zippered with belt loop
C$86.79 / each
3050 In Stock
Plastic carrying case with foam liner for 475-1-AV air velocity kit - 13-1/2" x 10" x 2-3/8".
C$151.80 / each
0 In Stock
A-47X-BOOT RBBR BOOT KIT/MANO
C$27.32 / each
70 In Stock
A-532 AIR VELOCITY
C$21.78 / each
1988 In Stock

installation hardware

A-375 CPRSN FTG 1/8TB X 1/8NPT
C$8.51 / each
619 In Stock

sensors

Pocket size Pitot tube, 1/8" dia., 6" insertion length, 3" tip, with 1/8" male NPT compression fitting.
C$246.71 / each
14 In Stock
Telescoping pitot tube
C$518.17 / each
19 In Stock
475-T AV KIT LESS MANO
C$821.63 / each
0 In Stock
Rated 5 out of 5 by from Fantastic device! This manometerworks incredibly well. Its feels good to know our magnahelics are accurate
Date published: 2026-07-27
Rated 4 out of 5 by from Great unit and easy to use . We use it every day Great unit and easy to use, the only thing it takes forever to arrive
Date published: 2026-02-14
Rated 5 out of 5 by from DywerOmega Manometer - Great Product! On point product - does offer everything as described. Works pretty accurate. Also came with add-on NIST calibration certificate. shipping was pretty quick.
Date published: 2025-11-10
Rated 2 out of 5 by from Disapointed Ordered 20 units, 10 10" WC and 10 20" WC. 16 were found bad and returned for repair, still waiting.
Date published: 2025-07-22
Rated 4 out of 5 by from A Great product A Great product that provides the correct readings
Date published: 2025-05-27
  • y_2026, m_8, d_25, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_CA, sid_475-000-FM, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

Does it measure vacuum pressure? (ie are the pressure ranges given in absolute pressure, or gauge pressure?)

Asked by: AnnaS
Hello, These measure positive differential pressure in gauge pressure. They can read vacuum if it is applied to the low port with the high port left open to atmosphere.
Answered by: AD Application Engineer
Date published: 2026-03-20

Can it be used in steam service? (I am interested in this product for steam ejector troubleshooting. The low pressure port would be connected to the jet mixing chamber, which is majority steam under vacuum.)

Asked by: AnnaS
Hello, These units are not compatible with steam.
Answered by: AD Application Engineer
Date published: 2026-03-23

What is the reference temperature of the inches of water units?

Asked by: MitchH
Hello, Our calibration system that we use on the handheld manometers assumes a reference temperature of 20&deg;C for inches of water column. It is also assumed at standard sea level conditions.
Answered by: AD Application Engineer
Date published: 2025-12-30
  • y_2026, m_8, d_25, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_475-000-FM, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 20ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration