Product Overview
  • Accuracy ± 0.4 %
  • Accuracy Class > 0.25%
  • Accuracy Detail ± 0.4% BFSL
  • Additional Features 1 None
  • Burst Pressure 8x Full Scale
  • Cable Length 0.9 m
  • Compensated Temperature, Max 82 °C
  • Compensated Temperature, Min -29 °C
  • Current Draw <3.0 mA
  • Enclosure Material 17-4 PH Stainless Steel
  • Gauge Type Thin-film polysilicone Piezoresistive
  • Hysteresis ± 0.2%
  • Insulation Resistance 100 MΩ
  • Mating Connector MIL-26482-I 8-4S
  • Operating Temperature, Max 82 °C
  • Operating Temperature, Min -28 °C
  • Pressure Cycles 100 million
  • Repeatability Error ± 0.05% full scale
  • Response Time 5 ms
  • Series ID PX603-PX613-PX605-PX615
  • Stability ± 1.0%
  • Supply Power Note 10 to 36 Vdc unregulated
  • Supply Voltage 10 to 36 Vdc
  • Thermal Effect on Span error, Max ± 0.07% FS/°C
  • Thermal Effect on Zero error, Max ± 0.07% FS/°C , ± 0.07% FS/°C
  • Weight 128 g

Supported Applications

The Omega PX602, PX603, PX605, PX612, PX613, and PX615 series are sealed pressure transducers designed for industrial pressure measurement applications. These units utilize chemical vapor deposited polysilicon strain gages to measure liquid or gas media across a broad range of pressures.

Documented capabilities include:

  • Vacuum to 20,000 psi (1380 bar) pressure ranges
  • Liquid and gas service compatibility
  • Industrial process monitoring requiring millivolt, voltage, or current outputs

Operating Conditions & Performance

The series delivers an accuracy of ±0.4% FS (BFSL), encompassing linearity, hysteresis, and repeatability. Hysteresis is specified at ±0.2% FS with a repeatability of ±0.07% FS. The response time for the transducers is 5ms.

Operating temperature limits are defined as follows:

  • Process Temperature: -20° to 180°F (-28° to 82°C)
  • Ambient Operating Temperature (PX605/PX615): -28 to 71°C (-20 to 160°F)
  • Compensated Temperature: -28° to 160°F (-28° to 71°C)

Storage temperature ranges from −65° to 250°F (−53° to 121°C). Thermal effects on zero and span are ±0.04% FS/°F.

Mechanical durability specifications include:

  • Shock Rating: <±0.05% FS effect at 100 G's, 20msec shock in any axis
  • Vibration Rating: <±0.1% FS effect for 0-2000 Hz @ 20G's in any axis
  • Fatigue Life: 100 million cycles at 20/80% FS with negligible performance loss

Pressure limits vary by range. For the 15-2000 PSI range, proof pressure is 200% FS and burst pressure is 800% FS. For the 3000-5000 PSI range, proof pressure is 150% FS and burst pressure is 300% FS. For the 7500-20,000 PSI range, proof pressure is 120% FS and burst pressure is 150% FS.

Configuration Options

The series offers configurable output signals, electrical connections, and process interfaces to accommodate diverse installation requirements. The housing material is NEMA 4X (304 SS) or NEMA 4 (IP65), with wetted parts constructed from 17-4 PH stainless steel diaphragm and 300 Series stainless steel case.

Output Signals & Electrical Specifications

  • PX602/PX612: Millivolt output (100mV ±1mV) with 10Vdc excitation (5-10Vdc limit @ 6mA max). Output impedance is 100Ω.
  • PX603/PX613: Voltage output (1-5Vdc, 3 wire) with 24Vdc excitation (10-36Vdc range). Supply current is <3mA; output impedance is 1000Ω.
  • PX605/PX615: Current output (4-20mA, 2 wire) with 24Vdc excitation (10-36Vdc range). Maximum loop resistance is calculated as 50 x (supply voltage -10)Ω.

Mechanical & Connection Options

  • Process Connections: Standard models feature a ⅛-18 NPT pressure port. Models rated for 15,000 to 20,000 PSI utilize a female AMINCO fitting (⅜-18 UNF).
  • Cable & Connector Styles: PX60x models are supplied with a cable; the braided shield is not connected to the transducer body. PX61x models feature connector options, specifically PT06F8-4S (sold separately for mating). The 0.9 m (36") braided shield PVC cable or connector style is available.
  • Dimensions: All units measure 0.8 inches square with an overall length of 3.780 to 3.8 inches (96.012 mm). Weight without cable is approximately 2 oz, while the PX605/PX615 series weighs 4.5 oz (128 g) without cable.

Calibration and testing are performed using instrumentation traceable to NIST standards, complying with MIL-STD-45662. Zero and span adjustments are accessible via pots located inside the case; zero is marked with a white dot.

Key Product Differences

The series distinguishes models by output type (millivolt, voltage, current) and electrical interface style (cable vs. connector).

  • PX60x Series: Cable-style transducers with a 36" braided shield PVC cable.
  • PX61x Series: Connector-style transducers designed for use with the PT06F8-4S mating connector (sold separately).

Model numbering indicates output type: PX602/PX612 are millivolt; PX603/PX613 are voltage; PX605/PX615 are current. Range codes in the model number specify pressure span, including vacuum ranges (e.g., 30VACI for Vacuum to 0 psig) and gauge pressures up to 20,000 psi.

Specific construction notes include that PX605 models ≤500 psi are vented to room air. For high-pressure applications (15,000-20,000 PSI), the sensor is supplied with a female AMINCO fitting rather than NPT threads. A pressure snubber (e.g., PS-4) is recommended for installation to protect against fluid hammer and surges.

Accessories

accessories

PRESS SNUBBER 1/4X1/4NPT OIL
C$34.22 / each
72 In Stock
TWIST LOCK CONNECTOR NON-ROHS
C$59.12 / each
110 In Stock

installation hardware

1/4" NPT, 10,000 psi Max. Pressure, for Water and Light Oil
C$33.83 / each
0 In Stock
1/4" NPT, 10,000 psi Max. Pressure, for Air, Steam and gases
C$34.22 / each
0 In Stock
Rated 4 out of 5 by from As Ordered Came as ordered, albeit a slightly long time to get for an in stock item
Date published: 2025-05-29
Rated 5 out of 5 by from Good Quality Pressure Sensor Item is very reliable, and it is easy to install and connect to 4-20 Ma PLC or control systems.
Date published: 2025-01-22
Rated 5 out of 5 by from Cylinder Testing Perfect for our cycle machines! we purchase at least 3-5 of these monthly. works like a charm.
Date published: 2024-02-05
Rated 5 out of 5 by from works well works well for my application. cost to performance is a good value
Date published: 2023-07-26
Rated 5 out of 5 by from Good product Good One and product quality very nice and i can see
Date published: 2023-05-11
Rated 5 out of 5 by from Fantastic product These items work very well for the application we use them for.
Date published: 2023-04-09
Rated 5 out of 5 by from Used with sub ambient cannister sampling. This worked well for our application of sub ambient cannister sampling. From -30 inHg to -6 inHg for record keeping.
Date published: 2020-11-12
  • y_2026, m_9, d_21, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_CA, sid_PX602-015GV, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

I'm connecting the wires to my own serial connector. What are the assignments of the white, green and red cables? I'm assuming green is data, red is +VDC and white is GND. Is that correct?

Asked by: scollie
Wiring would be as follows. Red is + Input Power, Green is + Output Signal, White is Common (- Input &amp; - Signal).
Answered by: Applicatrions Engineer JK
Date published: 2020-03-13

Are the Model PX615-30V15GI Class I Div. 2 compliant? If not, is there a similar Omega sensor that is?

Asked by: IanKHE
The PX605/615 Series Pressure Transmitters are not Class I Div 2 Compliant. The PX835-015CGI Intrinsically Safe Pressure Transmitter would meet you requirements.
Answered by: Applicatrions Engineer JK
Date published: 2021-06-30

What IP rating for this sensor? I want to use it with distilled water is it compatible with it&gt;

Asked by: Nainesh Lad
It is mentioned on attached pdf datasheet. NEMA 4 (IP65) Cable or Connector Models. Diaphragm: 17-4 PH stainless steel Case: 300 Series stainless steel. Ideal for Liquid or Gas
Answered by: App Eng
Date published: 2024-12-30

Regarding product Item# PX615-20KGI: what electrical certifications does it carry for US and Canadian operations. Are they UL, ULc, or CSA compliant? Thank you!

Asked by: twojtkowski
The PX615 Series pressure transmitters are not UL, ULc or CSA Compliant.
Answered by: Applicatrions Engineer JK
Date published: 2019-07-24

Is there a life expectancy on the PX615 series transducer? If so how long?

Asked by: NealC
Service life for PX615 is indefinite as long as it's operate within it's specified parameters. There are examples of theses sensors being in service for several years without any problems
Answered by: Applicatrions Engineer JK
Date published: 2019-11-16

Can I get the data from this sensor into my computer? Do you have any built-in application for this purpose or do I have to use the Data Acquisition Card to log the output voltage? If the later is true then tell me the conversion equation?

Asked by: Maverick81
You will need to use Data Acquisition card. The out is a linear 1 to 5VDC over the sensors calibrated pressure range. You can use the linear equation y=mx+b
Answered by: Applicatrions Engineer JK
Date published: 2021-10-04

Is the PX605-5KGI Model CSA ou cUL compliant?

Asked by: The process engineer
The PX605 Series pressure transmitters are not UL, cUL or CSA Compliant
Answered by: JK Applications Eng
Date published: 2024-06-21

Do you have a drawing about the &quot;High Pressure F-250-C&quot;, I need it to choose a fitting

Asked by: Young
Hello and thank you for your question. Could please contact the pressure department at Omega directly (pressure@omega.com)? We would be happy to provide you with a drawing!
Answered by: Pressure Eng
Date published: 2020-01-22
  • y_2026, m_9, d_21, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_en_CA, sid_PX602-015GV, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration