1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
 
					PX603-PX613-PX605-PX615
General Purpose Pressure Transducers with Adjustable Zero & Span
			Models In Stock
	
	PX603-PX613-PX605-PX615
					From
					C$
					692.74
				
						Models In Stock
				
			 
Product Overview
	Accessories
accessories
installation hardware
Show Ratings & Reviews
 
			
	
	
	
        
            Rated 4 out of
            5
         by
        Jeremiah from
        As Ordered
        Came as ordered, albeit a slightly long time to get for an in stock item
        
    Date published: 2025-05-29
        
    
        
            Rated 5 out of
            5
         by
        Mechanic from
        Good Quality Pressure Sensor
        Item is very reliable, and it is easy to install and connect to 4-20 Ma PLC or control systems.
        
    Date published: 2025-01-22
        
    
        
            Rated 5 out of
            5
         by
        Cody P from
        Cylinder Testing
        Perfect for our cycle machines! we purchase at least 3-5 of these monthly. works like a charm.
        
    Date published: 2024-02-05
        
    
        
            Rated 5 out of
            5
         by
        Jim Bob II from
        works well
        works well for my application. cost to performance is a good value
        
    Date published: 2023-07-26
        
    
        
            Rated 5 out of
            5
         by
        Good from
        Good product
        Good One and product quality very nice and i can see
        
    Date published: 2023-05-11
        
    
        
            Rated 5 out of
            5
         by
        Anonymous from
        Fantastic product
        These items work very well for the application we use them for.
        
    Date published: 2023-04-09
        
    
        
            Rated 5 out of
            5
         by
        Anonymous from
        Used with sub ambient cannister sampling.
        This worked well for our application of sub ambient cannister sampling. From -30 inHg to -6 inHg for record keeping.
        
Date published: 2020-11-12
        
    I'm connecting the wires to my own serial connector. What are the assignments of the white, green and red cables? I'm assuming green is data, red is +VDC and white is GND. Is that correct?
            Wiring would be as follows. Red is + Input Power, Green is + Output Signal,  White is Common (- Input & - Signal).
            
            
    Date published: 2020-03-13
        Are the Model PX615-30V15GI Class I Div. 2 compliant? If not, is there a similar Omega sensor that is?
            The PX605/615 Series Pressure Transmitters are not Class I Div 2 Compliant.  The PX835-015CGI Intrinsically Safe Pressure Transmitter would meet you requirements.
            
            
    Date published: 2021-06-30
        What IP rating for this sensor? I want to use it with distilled water is it compatible with it>
            It is mentioned on attached pdf datasheet. NEMA 4 (IP65) Cable or Connector Models. Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel. Ideal for Liquid or Gas
            
            
    Date published: 2024-12-30
        Regarding product Item# PX615-20KGI: what electrical certifications does it carry for US and Canadian operations. Are they UL, ULc, or CSA compliant? Thank you!
            The PX615 Series pressure transmitters are not UL, ULc or CSA Compliant.
            
            
    Date published: 2019-07-24
        Is there a life expectancy on the PX615 series transducer? If so how long?
            Service life for PX615 is indefinite as long as it's operate within it's specified parameters. There are examples of theses sensors being in service for several years without any problems
            
            
    Date published: 2019-11-16
        Can I get the data from this sensor into my computer? Do you have any built-in application for this purpose or do I have to use the Data Acquisition Card to log the output voltage? If the later is true then tell me the conversion equation?
            You will need to use Data Acquisition card.  The out is a linear 1 to 5VDC over the sensors calibrated pressure range. You can use the linear equation y=mx+b
            
            
    Date published: 2021-10-04
        Is the PX605-5KGI Model CSA ou cUL compliant?
            The PX605 Series pressure transmitters are not UL, cUL or CSA Compliant
            
            
    Date published: 2024-06-21
        Do you have a drawing about the "High Pressure F-250-C", I need it to choose a fitting
            Hello and thank you for your question. Could please contact the pressure department at Omega directly (pressure@omega.com)?
We would be happy to provide you with a drawing!
            
            
    Date published: 2020-01-22
         
						
						 
					
				