Skip to search Skip to main content Skip to navigation

Need assistance? Call us: 1-800-663-4209

We noticed you are in , please visit your local site by clicking the below link for regional offers and support.

FD-400-Series

Doppler Ultrasonic Flow Meter

  • Non-Intrusive, Clamp-On Transducer for Most Pipes from 6 mm to 3m (1/4 to 120')
  • Insertion Probe Transducer Also Available
  • Wide Measuring Range of 0.05 to 9 mps (0.15 to 30 fps)
  • ±2% of Calibrated Span Accuracy
FD-400-Series
From C$ 4,363.47
Doppler Ultrasonic Flow Meter FD-400-Series FD-400-Series
loading all models
Product Overview
  • Accuracy ± 2 %
  • Accuracy Detail ±2% FS over calibrated span
  • Cable Length 6 m
  • Calibration Option NIST
  • Display Note 2-line x 8-character LCD; LED backlighting; top row, 7-segment 18 mm (0.7"); bottom row, 14-segment 9 mm (0.35"); 8-digit rate, 8-digit total (resettable)
  • Display Type LCD
  • Enclosure Ratings IP66, NEMA Type 4X
  • Form factor Wall Mount
  • Keypad Yes
  • Materials Polycarbonate, Stainless steel, Brass, Plated-steel mounting brackets
  • Measurement Type Doppler Ultrasonic
  • Number of Digits 8
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Pipe Size, Max 120 in
  • Pipe Size, Min 0.3333 in
  • Response Time 1 to 60 sec
  • Series ID FD-400-Series
  • Supply Power Note 115/230 Vac, 50/60 Hz ±15% @ 5 VA max; 12 to 28 Vdc @ 2.5 VA max
  • Velocity, Max 9 m/s
  • Velocity, Min 0.05 m/s

Supported Applications

The Omega FD-400 Series Doppler Ultrasonic Flow Meter measures liquid flow rate using non-invasive clamp-on transducers or insertion probes. The series is designed for liquids containing suspended solids, gas bubbles, or other sonic reflectors greater than 100 microns at a concentration of 100 ppm. Documented media include water, wastewater, sewage, slurries, and chemicals.

Applications leverage the clamp-on installation method to measure flow on existing pipes without cutting or disrupting service. The system supports synchronization for up to four meters in a single piping system spaced up to 30 m (100') apart.

Operating Conditions & Performance

The FD-400 Series operates with a flow velocity range of 0.05 to 9 mps (0.15 to 30 fps). Accuracy is specified as ±2% FS over the calibrated span, with user-selectable response times from 1 to 60 seconds.

Operating conditions vary by transducer type:

  • Ambient Temperature (Monitor): -40 to 85°C (-40 to 185°F)
  • Process Temperature (Standard Clamp-On & Insertion Probe): -40 to 100°C (-40 to 210°F)
  • Process Temperature (High-Temp Clamp-On): -40 to 200°C (-40 to 400°F)
  • Pressure Rating: Up to 700 psi (48 bar) max for insertion probes; clamp-on ratings depend on pipe integrity.

The monitor enclosure is rated NEMA 4X (IP66). Standard clamp-on transducers are rated NEMA 6P (IP68), while high-temperature clamp-ons are rated NEMA 4 (IP65).

Configuration Options

The series offers a wide range of configuration options for power, output signals, and sensor installation methods.

  • Power Supply: Standard units accept 115/230 Vac (±15%, 5 VA max) or 12 to 28 Vdc (2.5 VA max). Specific power options are selected at order placement via model suffixes.
  • Output Signals: Models provide various combinations of 4-20 mA, rate pulse outputs, and control relays. The 4-20 mA output supports a load resistance up to 800 Ω max with optically isolated circuitry.
  • Relay Outputs: Dual relay configurations are available as form 'C', rated at 200 Vac @ 0.5 A resistive, configurable for rate alarm, totalizer pulse, or error indication.
  • Pulse Output: Rate pulse options include two types: 500 mVac (into 2 kΩ min) or open collector (1 A at 100 V max), with a maximum frequency of 2500 Hz.

Sensor and Installation Options

Transducers are sold separately from the monitor unit. The series supports multiple installation configurations:

  • Clamp-On Transducers: Available in standard sizes for pipes 25 mm to 3 m (1" to 120") and small-pipe sets for 6 to 25 mm (¼" to 1"). High-temperature versions are available for process temperatures up to 200°C.
  • Insertion Probes: Available in lengths from 8" to 48", featuring a NEMA 6 (IP67) rating. Wetted materials include 316 SS, Ultem®, FKM, and nylon.
  • Cable Lengths: Standard cable length is 6 m (20'). Options for 50' or 100' cables are available via model suffixes; armored conduit options require consultation with Engineering.

Display and Configuration

The monitor features a 2-line backlit LCD display showing rate and totalizer values. Units can be configured for various engineering units including feet, gallons, liters, cubic meters, acre-feet, oil barrels (42 gallon), liquor barrels (32.5 gallons), lb, and kg.

Key Product Differences

The FD-400 Series is differentiated by output configuration and power supply options:

  • FD-400: Basic rate and totalizer with no analog or relay outputs.
  • FD-41x Models (e.g., FD-410, FD-411): Include one or two 4-20 mA outputs; some models combine 4-20 mA with pulse or relay outputs.
  • FD-42x Models (e.g., FD-420, FD-422): Feature dual or quad relay configurations for alarm and control applications.
  • FD-43x Models (e.g., FD-430, FD-433): Provide rate pulse outputs in single or double channel configurations.

Power supply variations are indicated by suffixes such as "-230VAC" for 230 Vac units and "-24VDC" for 24 Vdc units. Transducer model numbers distinguish between standard clamp-on (FD-400C), small-pipe clamp-on, high-temp versions (-HT), and insertion probes (FD-400I).

Accessories

consumables

COUPLING GREASE FDT-30/FDT-80
C$136.69 / each
0 In Stock
6 GRM GREASE FOR FD/FDT SERIES
C$53.57 / each
10 In Stock
HIGH TEMP COUPLANT FD/FDT SER.
C$307.13 / each
2 In Stock
NON-SILICONE GREASE
C$136.69 / each
0 In Stock

sensors

SMALL PIPE CLAMP ON XDUCER SET
C$3,146.01 / each
0 In Stock
Small-pipe clamp-on transducer set, 6 to 25 mm (1.4 to 1 in) 15 m (50 ft)
C$3,308.81 / each
0 In Stock
Small-pipe clamp-on transducer set, 6 to 25 mm (1.4 to 1 in) 30 m (100 ft)
C$3,546.80 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
C$2,758.04 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
C$2,529.56 / each
0 In Stock
STD SIZE CLAMP ON XDUCER SET
C$2,340.76 / each
0 In Stock
Rated 3 out of 5 by from Works well, lacking in quality. Must double check the metered fluid has appropriate solid particle size and concentration. The totalizers typically last me about 1-2 years before it stops working. The transducers seem to last 2-4 years before needing to be replaced. Its not easy to get them repaired (transducers are repairable) through Omega customer service. In general, its a good meter for solid laden fluids (double check particle size and conc.) but I'd like to see the quality improved for longer life.
Date published: 2016-05-31
Rated 5 out of 5 by from Versatile Flow Meter Easy to set-up. Came fast. Large easy to read display
Date published: 2023-04-26
  • y_2026, m_8, d_3, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_FD-400, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 6ms
  • REVIEWS, PRODUCT

What comes in the box with the Item # FD-410?

Asked by: ReoL
Thank you for your inquiry. The FD-410 is the ultrasonic flow meter transmitter with the display and includes the wall mount bracket, NIST certificate, manual, and transducer is sold separately.
Answered by: JC ENGR
Date published: 2020-11-20

The installation manual (Fig 3.2) shows the transducer wires as red and black, however they are actually blue and white. How should they be wired?

Asked by: H20D
Thank you for your inquiry about the Doppler flow meter. The correct configuration is the Blue wire is Red per Fig 3.2 and the White wire is Black.
Answered by: Applications Engineer JC
Date published: 2021-06-11
  • y_2026, m_8, d_3, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_FD-400, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 5ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration