Need assistance? Call us: 1-800-663-4209
Series-636D
Differential Pressure Transmitter, 0.5% F.S., 4-20 mA, NEMA 4, CSA Approved
Models In Stock
- NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
- Explosion-proof device for use in hazardous areas
- Versatile, high-accuracy device for liquid or gas supports designs requiring more precise measurements in support of application
Series-636D
From
C$
3,034.68
Models In Stock
Product Overview
- Accuracy Detail BFSL: ± 0.5% FS (includes linearity, hysteresis, and repeatability)
- Applications Oil and Gas
- Burst Pressure 2500 psi Maximum
- Cable Length 2 ft
- Compensated Temperature, Max 71 °C
- Compensated Temperature, Min -29 °C
- Compliance Note CSA approved explosionproof for Class I, Division 1, Groups B, C, and D; Class II, Groups E, F, and G; Class III.
- Display Type N/A
- Electrical Connection 3/4 in NPT female Conduit with Screw Terminal block
- Enclosure Ratings IP56, NEMA Type 4
- Long Term Stability ± 1% FS/year
- Media Compatibility Fuel gases, HVAC / room air, Inert / non-reactive gases, Steam, Hydrogen, Nitrogen, Oxygen
- Mounting Note Horizontal Diaphragm
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -40 °C
- Measurement Pressure Type Differential
- Process Connection Size 1/2 in
- Process Connection Type NPT Female
- Process Temperature, Max 100 °C
- Process Temperature, Min -40 °C
- Response Time 20 ms
- Series ID Series-636D
- Span Adjustment Fixed
- Storage Temperature, Max 100 °C
- Storage Temperature, Min -40 °C
- Thermal Effects ± 2% FS/50°F
- Thermal Effects Note ± 2% FS/50°F (reference to 77°F)
- Weight 0.82 kg
- Wire Gauge 22 AWG
- Zero Setting Adjustable Range Fixed
Supported Applications
The Dwyer Series 636D is a fixed-range differential pressure transmitter designed for measuring pressures of compatible gases, liquids, or vapors. The unit features an all stainless steel construction with Types 316L SS wetted materials to endure harsh environmental and media conditions. It is CSA approved explosion-proof for use in hazardous locations (Class I, Division 1, Groups B, C, and D; Class II, Groups E, F, and G; Class III) and meets NACE standards for offshore applications.
Operating Conditions & Performance
The Series 636D delivers an accuracy of ±0.5% FS (includes linearity, hysteresis, and repeatability) with a stability of ±1.0% F.S./yr. The compensated temperature range is -20 to 160°F (-29 to 71°C), while the thermal effect is specified as ±2% F.S./50°F (reference to 77°F). Ambient operating temperatures span -40 to 140°F (-40 to 60°C); process interface and storage limits are rated from -40 to 212°F (-40 to 100°C).
Pressure handling capabilities include a limit of 3 x FS differential pressure with a burst rating of 2500 psig. The response time is 20 ms, and the unit maintains performance within ±0.05 psi/90° rotation from horizontal mounting orientation.
Configuration Options
The series offers configurable output signals and measurement ranges to address specific process needs:
- Output Signals: 4-20 mA DC or optional 1-5 VDC. Power requirements are 12-30 VDC for current outputs and 8-14 VDC for voltage outputs, both with reverse polarity protection.
- Measurement Ranges: Available in nine fixed ranges from 0 to 6 psid up to 0 to 500 psid (specifically: 0–6, 0–15, 0–30, 0–60, 0–100, 0–150, 0–200, 0–300, and 0–500 psid).
- Enclosure & Connections: Features a NEMA 4 (IP56) all-316 welded construction housing. Process connections consist of two 1/2" female NPT ports; electrical connection includes a 2 ft, 22 AWG cable and a 3/4" female NPT conduit.
- Options: A NIST traceable calibration certificate is available (order code: NISTCAL-PT1).
Key Product Differences
The Series 636D distinguishes between output types via model suffixes. Models ending in "-LP" denote the optional 1-5 VDC output, while standard models provide a 4-20 mA DC output (e.g., 636D-0 for 4–20 mA vs. 636D-0-LP for 1–5 VDC). Both variants share identical measurement ranges and physical specifications.
Zero and span adjustments are fixed; the transmitter is not field serviceable and must be returned to Dwyer if repair is needed.
PDFs & Manuals
Accessories
Static Pressure Sensors for Manometers & Gages across Air Filters
From C$3.77
0 In Stock
calibration