Need assistance? Call us: 1-800-663-4209
TCCTL
Cut to Length Thermocouple Probes for Field Adaptation
Models In Stock
- Field Cutable to the Length Needed Using a Tubing Cutter [76 mm (3') Length Minimum]
- Available in All Base Metal Thermocouple Calibrations (Types J, K, T, E and N)
- 6 and 4.5 mm (1/4 and 3/16') Diameters Standard
- PFA and Two Fiberglass Insulated Cable Options Available
TCCTL
From
C$
136.71
Models In Stock
Product Overview
- Color Code Standard ANSI
- Length to Cut, Min 3 in
- Number of Connectors N/A
- Probe Length 24 in
- Probe Type Cut to Length Thermocouple Probe
- Process Temperature, Min 0 °C
- Series ID TCCTL
- Sheath Material 304 Stainless Steel
- Temperature Sensor Type Thermocouple
- Wire Gauge 24 AWG
Supported Applications
The Omega TCCTL Series consists of cut-to-length thermocouple probes designed for field-adaptable temperature measurement applications. These immersion probes are engineered to be trimmed on-site using a tubing cutter, with a minimum required length of 76 mm (3"). The series supports all base metal thermocouple calibrations: Types J, K, T, E, and N.
Operating Conditions & Performance
The TCCTL probes feature a sheath constructed from 300 Series Stainless Steel. Standard probe length is 600 mm (24"). Maximum operating temperatures depend on the cable insulation type selected:
- Type TT Leads: 260°C (500°F)
- Type GG Leads: 482°C (900°F)
- Type HH Leads: 540°C (1000°F)
Sheath diameters are available in standard sizes of 6 mm (¼") and 3/16". Note that Type "HH" cable is not available with Type T or Type E thermocouples.
Configuration Options
The series offers extensive configuration options for mounting, termination, and sensor geometry to accommodate specific installation requirements.
Cable Insulation & Temperature Ratings
- PFA insulated cable (Type TT)
- Fiberglass insulated cable rated 482°C (900°F) by changing "TT" to "GG" in the model number at no additional cost.
- Fiberglass insulated cable rated 540°C (1000°F) by changing "TT" to "HH" for an additional cost.
Tip Configuration & Elements
- Ungrounded tip: Standard configuration indicated by "U" in the model number.
- Grounded tip: Available at no additional cost by changing "U" to "G" in the model number.
- Dual element options are available for specific configurations (e.g., TCCTL-J-14U-24-40-TT-DUAL).
Connectors & Mounting
- Add a standard sized connector by adding "-OSTW" to the model number for additional cost.
- Add a miniature connector by adding "-SMPW" to the model number for additional cost.
- Stainless steel and brass compression fittings are available for mounting (see "SSLK or BRLK" fittings).
Key Product Differences
The TCCTL series is defined by a modular model numbering system: TCCTL-----. For example, the part number TCCTL-K-6U-600-1-TT denotes a Type K cut-to-length thermocouple with a 6 mm (¼") diameter sheath, 600 mm (24") probe length, and PFA insulated cable 1 m (40") long. Variations in the model number directly correspond to changes in thermocouple type, sheath size, insulation rating, tip grounding status, or connector presence.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Red lion Controls from
Thermocouple Probe Product
Really Great Product and team .as delivery and product on time .
Date published: 2021-02-15