Passer à la recherche Passer au contenu principal Passer à la navigation

Besoin d'aide? Appelez-nous: 1-800-663-4209

Nous avons remarqué que vous êtes dans , veuillez visiter votre site local en cliquant sur le lien ci-dessous pour des offres et un support régionaux.

PRCTL

Sondes RTD à longueur coupée pour adaptation sur le terrain

Cut to Length RTD Probes for Field Adaptation
Modèles en stock
  • Probe Is Supplied 24' Long and Designed To Be Cut-To-Length as Needed Using a Simple Tube Cutter.
  • Great For Use As Replacement Sensors, Can Be Combined With a Wide Variety Of Spring Loaded Fittings, Compression Fittings, Connection Heads, Thermowells, Connectors or Other Accessories to Fit a Wide Variety of Applications.
  • Contains a Precision pt100 Ohm DIN Platinum Thin Film Element in Either Class A or Class B Accuracies.
  • Temperature Range: -50 to 260ºC
PRCTL
À partir de C$ 186.92
Modèles en stock
Cut to Length RTD Probes for Field Adaptation PRCTL PRCTL
loading all models
Aperçu du produit
  • Insulation Note PFA Insulated Lead Wires Standard– Available with SS Overbraid; Available with Glass Insulation
  • Nominal Resistance/Curve Note Available in 100 Ω DIN Platinum Class “A” or Class “B”
  • Probe Length 24 in
  • Probe Type Cut to Length RTD Probes
  • Process Temperature, Max 260 °C
  • Process Temperature, Min -50 °C
  • Sensor Note All Sensors Supplied with IEC60751/ ASTM E-1137 Color Codes
  • Series ID PRCTL
  • Sheath Material 316 Stainless Steel
  • Temperature Probe Style Immersion Probe
  • Temperature Sensor Type RTD
  • Wire Gauge 26 AWG

Supported Applications

The Omega PRCTL Series consists of Cut-to-Length RTD (Resistive Temperature Device) probes designed for field-adaptable temperature measurement applications. These sensors feature a hermetically sealed construction with PFA insulated lead wires, allowing engineers to trim the sheath on-site using a standard tube cutter to match specific installation requirements.

Operating Conditions & Performance

The PRCTL series operates within a process temperature range of -50 to 260°C. The sensors are available in two accuracy classes per IEC standards: Class A with an accuracy of ±0.15°C @ 0°C, and Class B with an accuracy of ±0.30°C @ 0°C.

Key performance characteristics include:

  • Sensor Element: Platinum RTD (100 Ω at 0°C).
  • Electrical Connection: Standard 3-wire configuration; a 4-wire option is available by modifying the model number.
  • Color Coding: Wires follow IEC60751 and ASTM E-1137 standards.

Configuration Options

The series offers extensive configurability to accommodate diverse mechanical constraints. The 316 Stainless Steel sheath is field-cuttable, with a minimum length of 3" after trimming. Standard configurations include specific diameters and lengths, but the model number structure supports custom dimensions.

Sheath Dimensions

  • Diameters: Available in ¼", ⅜", 6 mm, and 4.5 mm.
  • Sensor Lengths: Standard lengths include 24" (imperial) or 600 mm (metric). Longer sheath lengths are available by specifying the desired length in the model number, with additional cost per inch or per 25 mm increment.

Lead Wire Options

  • Insulation: Standard PFA insulated lead wires; glass insulation is an option (add '-GG' to model number).
  • Protection: Stainless steel overbraid on the PFA insulated lead wires is available (add '-SB' to model number).
  • Wire Lengths: Standard lengths include 40" or 1 m. Longer wire runs are configurable by changing the length value in the model number, with additional cost per foot or per 300 mm.

Key Product Differences

Variants within the PRCTL series differ primarily by accuracy class (A vs. B), sheath diameter, and lead wire configuration. The standard offering is a 100 Ω sensor; however, variants with different resistance values exist in the broader catalog structure.

  • Accuracy Class: Models are designated as 'A' for IEC Class A or 'B' for IEC Class B accuracy.
  • Wire Configuration: The second digit of the model number indicates wire count: '2' denotes a 3-wire configuration, while changing this to '3' specifies a 4-wire setup.
  • Imperial vs. Metric: Model numbers reflect either imperial dimensions (inches) or metric dimensions (mm), with corresponding standard lengths of 24"/600 mm and wire lengths of 40"/1 m as baseline configurations.

Accessoires

accessories

Tube Cutter
/ each
4 En stock

cables

3-Prong Mini flat pin Connector for Thermocouple, RTD and 3-Wire Thermistor
TWD220 / each
1296 En stock

installation hardware

STD THRD WELL FOR 1/4"
/ each
3 En stock
STD THRD WELL FOR 1/4"
/ each
4 En stock
Standard thermowell
TWD2,015 / each
0 En stock
OMEGALOK™ Compression Fittings
TWD462 / each
0 En stock
Thermocouple and RTD Protection Heads
/ each
0 En stock
Spring Loaded Fittings for 1/4" Diameter Probes
/ each
0 En stock
OMEGALOK™ Compression Fittings
TWD969 / each
1224 En stock

meters/controllers

1/8 DIN On-Off Temperature or Process Controllers with 5 Ramp and Soak Programs plus 2 Timers with Optional Outputs
TWD17,062 / each
3 En stock
Hochgenaue PT100 RTD-Eingangsthermometer
251,98 € / each
0 En stock
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

is there a 3d or STEP file we can download

Asked by: joseph231
Unfortunately Omega does not provide 3D drawings on any products and the best illustration is on the product pages for probes.
Answered by: ApplicationEngineerANB
Date published: 2021-04-01

What is the minimum length that the RTD cut to length PT 100 Sensor probes can be cut too?

Asked by: BlaaBlaa
3" is the smallest length the probe can be cut.
Answered by: Temperature
Date published: 2021-04-21
  • y_2026, m_9, d_21, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_PRCTL-2-1000-B-1-4-24-40, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 31ms
  • QUESTIONS, PRODUCT
fr-CA
en_CA
Enregistrer la configuration