HHM-EX623
Clamp Meter 400 A Dual Input with Non-Contact Infrared Thermometer and Voltage
Choose a Variant
Product Specs
<< See all Product Models| Brand |
|
| AC Response | True RMS (Aac and VAC) |
| Additional Features 1 | 400 A max Current |
| Altitude,Max | 2000 m |
| Auto Power Off | After approx. 30 minutes, with disable |
| Bandwidth | 50 to 400 Hz (Aac and VAC) |
| Battery Indication | Displayed |
| Capacitance | 10pF to 40000μF |
| Capacitance Resolution | 0.01nF |
| Clamp Jaw Opening Length | 32 mm |
| Commodity Code | 9030.31.0000 |
| Continuity Test | Threshold 50 Ω; test current < 0.5mA |
| Crest Factor | 3.0 in 40A and 400A ranges, 1.4 in 1000A range (50/60 Hz and 5% to 100% of range) |
| Current Accuracy | ± 1.5 % |
| Current Measurement Range | 400 A/4000 μA |
| Current Resolution | 10 mA |
| DepthValue | 6.1 |
| Diode Test | Test current of 0.3 mA typical |
| Display Range | Dual 40000/4000 |
| Display Type | Backlit LCD |
| Display and Indications | OL |
| Duty Cycle | 0.5 to 99.0% |
| ECCN | EAR99 |
| EMC Standard | EN61010-1 |
| Frequency | 40 MHz |
| Frequency Resolution | 0.001Hz |
| Fuse Rating | Ceramic Fast Blow, 500 mA |
| GrossWeightValue | 1.67 |
| Height | 229 mm |
| HeightUoM | IN |
| HeightValue | 3.25 |
| Impedance Input | 10M Ω (Vdc and Vac) |
| Infrared Temperature Features | IR Spectral Response: 6 to 16 um; IR Emissivity: 0.95 fixed; IR Distance Ratio : 8:1;Laser Pointer: Class 2 Laser |
| Laser Power | < 1 mW |
| Laser Wavelength Color | 630 to 670 nm |
| Length | 49 mm |
| Measurement Type | AC/DC Voltage/Current, Resistance, Capacitance, Frequency, Dual Type K Temperature, IR |
| Measuring Temperature Range, Max | 1000 °C |
| Measuring Temperature Range, Min | -50 °C |
| NetWeightValue | 1.67 |
| Non-Contact Voltage Measurement Range | 100 to 600 Vac |
| OkForExport | true |
| Open_Circuit Voltage | 2.8 Vdc typical |
| Operating Humidity | 0 to 80% RH |
| Operating Temperature, Max | 40 °C |
| Operating Temperature, Min | 5 °C |
| Process Temperature, Max | 270 °C |
| Process Temperature, Min | -50 °C |
| Resistance | 40 MΩ |
| Resistance Resolution | 0.01Ω |
| Sampling Rate | 2 Hz (2 updates/second) |
| Series ID | HHM-EX623-Clamp-Meter |
| Storage Humidity, Max | < 80 % |
| Storage Temperature, Max | 60 °C |
| Storage Temperature, Min | -20 °C |
| Supply Power Type | Battery |
| Taxonomy Level 1 | QGV |
| Taxonomy Level 2 | ME |
| Taxonomy Level 3 | HH |
| Taxonomy Level 4 | PO |
| Thermocouple Type | Type K thermocouple |
| Voltage Measurement Range | 600 V |
| Voltage Resolution | 0.1 mV/0.01 mV |
| Weight | 303 g |
| WeightUoM | LB |
| Width | 80 mm |
| WidthValue | 12 |
| See All Specs | |