Ceramic Fibre or Silica Insulated Thermocouple Elements

Models In Stock
  • Standard 0.3 m (12") Long Thermocouple Elements
  • Insulation Temperature Rating Up to 1200°C (2200°F)
  • Available In Type K, E and J Calibrations
XC
From C$ 44.38
Models In Stock
Ceramic Fibre or Silica Insulated Thermocouple Elements XC XC
loading all models
Product Overview
  • Insulation Nextel®
  • Junction Type Exposed
  • Process Temperature, Min 0 °C
  • Series ID XC

Supported Applications

The Omega XC Series consists of Nextel®-covered flexible thermocouple elements designed for high-temperature applications. These ceramic-insulated sensors feature a flexible design intended for hard-to-reach locations and are compatible with OMEGA® ceramic protection tubes and wells.

Operating Conditions & Performance

The series supports continuous use up to 1200°C (2200°F) or short-term exposure up to 1425°C (2600°F). Accuracy meets or exceeds Special Limits of Error (SLE) of ANSI MC96.1-1982 and EN 60584-2, Tolerance Class 1. Temperature limitations are determined by the type of thermocouple material selected.

Measurement Ranges

The available temperature ranges vary by thermocouple type and AWG size:

  • Type K: 0 to 1090°C (32 to 2000°F) for 14 AWG; 0 to 980°C (32 to 1800°F) for 20 and 24 AWG
  • Type J: 0 to 590°C (32 to 1100°F) for 14 AWG; 0 to 480°C (32 to 900°F) for 20 AWG; 0 to 370°C (32 to 700°F) for 24 AWG
  • Type E: 0 to 650°C (32 to 1200°F) for 14 AWG; 0 to 540°C (32 to 1000°F) for 20 AWG; 0 to 430°C (32 to 800°F) for 24 AWG
  • Type N: 0 to 1090°C (32 to 2000°F) for 14 AWG; 0 to 980°C (32 to 1800°F) for 20 and 24 AWG

Configuration Options

The XC Series is configurable across multiple dimensions including thermocouple type, wire gauge, length, insulation material, and connector options.

Sensor Elements & Insulation

  • Thermocouple Types: K, J, E, N
  • American Wire Gauge (AWG): 14, 20, 24
  • Insulation Material: Nextel® ceramic fiber insulation is standard. Silica insulation is available by changing the series prefix from 'XC' to 'XS' with no additional cost.
  • Overbraiding: Stainless steel or Inconel® overbraiding for abrasion protection (consult Sales).

Dimensions & Termination

  • Standard Length: 300 mm (12"). Other lengths are available; to order longer elements, change the '12' in the model number to indicate the actual length required.
  • Termination: 13 mm (0.5") stripped end termination with color-coded leads.

Connector Options

Add the following codes to the model number for additional cost:

  • M8-S-M: Male straight M8 plug
  • M12-S-M: Male straight M12 plug (listed as 'M12-S-M' in options; note that right-angled 12mm is also listed as 'M12-S-M' in the source text)
  • M8-R-M: Male right-angled M8 plug
  • Male right-angled M12 plug (add to model number for additional cost)

Assembly Integration

OMEGA can combine these elements with thermowells and industrial heads to produce a complete head and well assembly, available for fast delivery.

Key Product Differences

The primary variation within the series is defined by the model number format: XC-<AWG>-<Type>-12 (example: XC-20-J-12). The 'XC' prefix denotes Nextel® ceramic fiber insulation, while changing this to 'XS' specifies silica insulation. Specific lengths are indicated in inches at the end of the part number.

Rated 4 out of 5 by from Thermocouple I bought this a few weeks ago. I've had issue with the metal ring that holds the sheathing on but other than that it's been a good sturdy product.
Date published: 2017-08-16
Rated 5 out of 5 by from Good Durability Very good durability and ability to stand up to nearly 1000°C temperatures.
Date published: 2026-07-16
Rated 5 out of 5 by from Braided Ceramic Very High Temperature This works just as promised on published specification sheet. Have used it multiple times. Never had any quality related issues.
Date published: 2022-01-21
Rated 5 out of 5 by from Quick and easy order! Easy to order, front page allows for multiple part number entries so you can go to what you need quickly.
Date published: 2020-08-28
Rated 5 out of 5 by from works great works like it should, nice heavy duty thermocouple.
Date published: 2018-09-05
Rated 4 out of 5 by from Works as expected Good TC for kiln.....................................
Date published: 2018-07-02
Rated 5 out of 5 by from XC-24-K and 5TC-TT-K-20-36 Using XC-24-K and 5TC-TT-K-20-36 since 8 and 1 year respectively. Former is very sturdy and insulation works fine till 800C for about a week of continuous exposure. ( max. we tried), Latter is very responsive to small temperature changes but amenable to insulation damage at high temperatures. Both has a very minimal (<0.1 degree) noise when used with standard recorder?controllers- Omega: OMDAQXL or Eurotherm: Nanodac or 2416 Overall a good and stable response.
Date published: 2018-05-18
  • y_2026, m_8, d_13, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_CA, sid_XC-14-J-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

How many wires do you get? 4 like shown or just 1?

Asked by: Bonez10
The XC-14-K-24 is sold individually.
Answered by: Engineer9
Date published: 2020-01-14

Hi, how inaccurate will the XC-20-K-24 (TC) be if I buy without calibration?

Asked by: kensho
Without the calibration the tolerance specifications would be +/- 1.1&deg;C or 0.4%.
Answered by: AndrewA
Date published: 2020-11-10

What is the diameter of the insulated wire bundle? XC-24-K-24

Asked by: hansen68
Nominal diameter is 0.115 x 0.175&quot;
Answered by: ANB ENG
Date published: 2020-11-10

Is a calibration (with certificate) included?

Asked by: rjm69
Thank you for your inquiry. Calibration Certificates does not come included with thermocouples. You will need send a request to temp@omega.com to receive a quote for a calibrated thermocouple.
Answered by: Application Engineer CB
Date published: 2023-02-09

Can I use a Campbell Scientific data logger to record readings? What is the output of the sensors?

Asked by: scottyS
  • y_2026, m_8, d_13, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_CA, sid_XC-14-J-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration