Product Overview
  • Color Code Standard ANSI
  • Mounting Bolt-On
  • Process Temperature, Min 0 °C
  • Series ID WT
  • Wire Gauge 20 AWG
  • Wire Type Solid

Supported Applications

The Omega WT Series consists of Bolt-On Washer Thermocouple Assemblies designed for mounting to various surfaces. These surface-mount sensors utilize a washer bolt-on design that secures the sensor against flat or curved planes using standard screw sizes.

Operating Conditions & Performance

Performance is defined by the insulation material selected, which dictates the maximum process temperature:

  • Glass insulated wire: Rated up to 480°C (900°F).
  • PFA insulated wire: Rated up to 260°C (500°F). Models with PFA insulation are identified by the "TT" suffix in the model number.

The series meets or exceeds Special Limit of Error (SLE) and EN 60584-2; Tolerance Class 1. Construction utilizes 20 AWG solid wire with a grounded junction configuration.

Mounting Dimensions

The washer hole diameter corresponds to specific American and Metric nominal screw sizes:

  • #6 / M3.5: Washer Hole Diameter 3.68 mm (0.145 in).
  • #8 / M4: Washer Hole Diameter 4.32 mm (0.170 in).
  • #10 / M4.5: Washer Hole Diameter 4.95 mm (0.195 in).
  • ¼" / M6: Washer Hole Diameter 6.60 mm (0.260 in).

Lead Lengths

Standard lead lengths are available as follows, with custom lengths over 60 inches configurable by modifying the model number length code:

  • 12" (300 mm)
  • 24" (600 mm)
  • 36" (900 mm)
  • 60" (1500 mm)

Configuration Options

The WT Series is configurable across thermocouple types, insulation materials, lead lengths, and electrical terminations.

Sensor Types

  • Type J (Iron-Constantan)
  • Type K (Chromel-Alumel)
  • Type T (Copper-Constantan)
  • Type E (Chromel-Constantan)

Electrical Connections & Terminations

Stripped end leads are standard. Optional terminations require adding specific suffixes to the model number:

  • #10 Spade Lugs: Add suffix "-L".
  • Standard OSTW Connectors: Male (add "-OSTW-M") or Female (add "-OSTW-F").
  • Molded Standard Round Pin Connector: Male (add "-LRTC").
  • Miniature SMPW Connectors: Male (add "-SMPW-M") or Female (add "-SMPW-F").
  • Molded Miniature Male Connector: Add suffix "-SRTC".

Special Options

The following options are available upon inquiry with sales:

  • Kapton® Insulation
  • Custom lengths or sizes beyond standard offerings

Key Product Differences

Variants within the series differ primarily by thermocouple type, insulation material (glass vs. PFA), washer size, lead length, and termination style.

  • Insulation: Standard models feature glass braid insulated wire; adding "-TT" to the model number specifies PFA insulated wire for lower temperature applications up to 260°C (500°F).
  • Sizing: The second digit in the model code indicates washer size: 6 (#6/M3.5), 8 (#8/M4), 10 (#10/M4.5), or 14 (¼"/M6).
  • Length Coding: The final numeric segment denotes lead length in inches (e.g., "-12", "-24", "-36", "-60").
Rated 5 out of 5 by from This was EXACTLY what I was looking for! This item had great build quality. It was easy to find and place an order for. We will definitely be purchasing more in the future.
Date published: 2026-01-14
Rated 5 out of 5 by from Solid, dependable product We have been ordering and using these in our semiconductor machines for global sales since 1997 and have not used anything else. High quality and dependable product.
Date published: 2025-08-26
Rated 5 out of 5 by from Bolt-On Thermocouples These have been our go-to thermocouples for over 10 years for testing purposes in our Halt-Hass Chamber test environment that are well proven and long lasting.
Date published: 2025-08-04
Rated 5 out of 5 by from love the speed it took for this order Great Customer Service, speedy shipping, fast quotes
Date published: 2025-05-13
Rated 5 out of 5 by from Thermocouple perfection The parts were exactly what the team was looking for in an assembly process
Date published: 2024-01-08
Rated 5 out of 5 by from Just what we needed These thermocouples were the form factor we needed for our application. They will work great
Date published: 2023-01-24
Rated 5 out of 5 by from just what I needed the part was out of stock but they still came in a timely manner and worked as excepted, will be a repeat customer
Date published: 2022-11-17
Rated 5 out of 5 by from Rock-On for the Bolt-On Washer! The part met our specs precisely and was in great condition and appropriately priced.
Date published: 2022-11-03
  • y_2026, m_9, d_4, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_10
  • loc_en_CA, sid_WTE-10-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

What is the outer diameter of the wire with PFA insulation?

Asked by: JDCT
The overall nominal outer diameter of the PFA lead wire for the WT series is 0.068 x 0.116".
Answered by: ApplicationEngineerANB
Date published: 2020-05-10

Does a thermocouple that is designed to be bolted to a surface measure the environment very well? I want to measure the temperature of the air using a similar thermocouple

Asked by: CJames
Thank you for your inquiry C James. You can use a Bolt-On Thermocouple to take air temperature measurements.
Answered by: Application Engineer MC
Date published: 2022-08-25

Are these Made in Canada or USA ?

Asked by: Anonymous
Thank you for your inquiry. They made in the USA.
Answered by: Application Engineer MC
Date published: 2023-10-01

What is meaning of Minimum Temperature Measurement - 60 in

Asked by: Bobble
The heading is incorrect for the column and should read "Lead wire length" and it will be corrected.
Answered by: ANBENG
Date published: 2020-02-17

Can these be used in environments where high EMI/EMF is expected?

Asked by: rm909
It's difficult to say if these probes would be good or not in that type of environment. There is no special shielding and it is a grounded junction probe so any surface it is attached to if it had this energy induced on it would go right into the TC junction. The safest answer is no or experiment at your own discretion.
Answered by: ApplicationsEngineerANB
Date published: 2024-05-17

Hi, is it possible to use wtk-6-12 on an high voltage cable (70 kV) without damaging the measurement system?

Asked by: gaara
The WT series would not be suitable for mounting to a surface with any Voltage as it is a grounded junction and the readings would not be good and it could damage your instrumentation.
Answered by: ApplicationEngineerANB
Date published: 2024-11-21

Can this be used on a heat press machine for temp sensor

Asked by: Printer
Thank you for your inquiry. Yes it can.
Answered by: Application Engineer CB
Date published: 2023-01-31

Do these parts meet the requirements of RoHS directive 2015/863/EU?

Asked by: blashway
Thank you for your inquiry. These parts are RoHS Compliant.
Answered by: Application Engineer CB
Date published: 2022-06-10
  • y_2026, m_9, d_4, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_20
  • loc_en_CA, sid_WTE-10-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 4ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration