Product Overview
  • Accuracy Class > 0.25%
  • Additional Features 1 8 Selectable Units
  • Battery Size and Type Alkaline AAA
  • Data Interface N/A
  • Height 132.9 mm
  • Length 24.7 mm
  • Number of Batteries 2
  • Number of Digits 5
  • Operating Temperature, Max 50 °C
  • Operating Temperature, Min 0 °C
  • Pressure Resolution 0.1 hpa
  • Series ID HHC280-Series
  • Supply Power Note 2 “AAA” batteries (included)
  • Width 50.9 mm

Supported Applications

The Omega HHC280-Series comprises rugged handheld environmental test meters designed for field engineering. The series includes the HHC280 differential manometer and the HHC281 absolute pressure meter, alongside companion models covering temperature (HHC201/HHC210), RPM (HHC250), light intensity (HHC230), and air velocity/humidity/dew point/wet bulb measurements (HHC261). Documented applications for the HHC280 differential manometer include HVAC system troubleshooting, gas pressure measurements, and use with pitot tubes to measure air velocity.

Operating Conditions & Performance

The series operates within an ambient temperature range of 0 to 50°C (32 to 122°F). The HHC280 differential manometer measures a primary pressure range of 0 to 100 hPa / 0 to 1019.7 mmH2O, with selectable units including mmHg, psi, inH2O, inHg, mbar, and Pa. Accuracy for the HHC280 is specified as ±0.03 hPa (0 to 0.30 hPa); ±0.05 hPa (0.31 to 1.00 hPa); ±0.1 hPa + 1.5% of rdg (rest of range). In mmH2O units, accuracy is ±0.3 mmH2O (0 to 3.0 mmH2O); ±0.5 mmH2O (3.1 to 10.2 mmH2O); and ±1.02 mmH2O + 1.5% of rdg for the remainder of the range.

The HHC281 absolute pressure meter covers a range of 300 to 1200 hPa with an accuracy of ±3 hPa, supporting barometric and altitude measurements. Both models feature Hold/Min/Max/Max-Min/AVG functions, auto power-off after 10 minutes, and a backlight that automatically turns off after 15 seconds.

Configuration Options

The HHC280-Series offers configurable measurement units and specific process connections tailored to the model. The handheld form factor includes dimensions of 24.7 x 50.9 x 132.9 mm (0.98 x 2.0 x 5.2") across models, with weights ranging from 110 g (HHC250) to 148 g (HHC201/HHC210). Power is supplied by two "AAA" batteries included in the package.

  • Process Connections: The HHC280 features dual pressure inputs P1 and P2 with hose barbs. It supports eight selectable units plus air velocity readouts (m/s, fmp).
  • Housing & Protection: All models include a slip-off hard cover shell, rubber bumper, carrying strap, and protection cap.
  • Battery Life: Typical battery life with alkaline batteries varies by model: HHC280 (85 hours), HHC281 (600 hours), HHC201 (250 hours), HHC210 (40 hours with laser), HHC250 (30 hours), HHC230 (180 hours), and HHC261 (50 hours).
  • Approvals: The series carries CE certification.

Key Product Differences

The bundle distinguishes between discrete models within the broader handheld family. The HHC280 is a differential manometer with dual inputs, while the HHC281 is an absolute pressure meter configured for barometric and altitude readings (units include m and ft). Other series members serve distinct measurement functions: the HHC201 is a dual input Type K thermocouple thermometer; the HHC210 combines infrared temperature sensing with air temperature measurement; the HHC250 measures RPM/rps; the HHC230 quantifies light intensity in lux/fc; and the HHC261 functions as a hygro-anemometer for air velocity, humidity, and dew point.

Resolution varies by unit selection on the HHC280: 0.1 hPa/0.1 mmH2O (primary), with per-unit resolutions of 0.01 mmHg, 0.001 psi, 0.01 inH2O, 0.001 inHg, 0.01 mbar, and 1 Pa.

Rated 3 out of 5 by from Good Basic Instrument I purchased this Manometer for laboratory testing on residential HVAC duct systems. I am measuring duct pressure "Inches/WC. The specifications stated the Instrument had an "averaging" feature which I badly needed. Turns out the "averaging" feature was only for wind speed, so that was very disappointing. But the instrument works very well and provides stable readings.
Date published: 2016-10-05
Rated 5 out of 5 by from Well-priced, accurate, and arrived quickly! It is almost impossible to find an absolute pressure gauge that can cover these ranges. It was relatively inexpensive, accurate, and I received it in just a couple of days after a very easy ordering process. Great product!
Date published: 2019-02-15
  • y_2026, m_8, d_4, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_CA, sid_HHC280, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT

Would this unit be suitable for measuring pressure differentials across adjacent cleanrooms of a cleanroom suite? In particular, I want to use the absolute pressure unit because I don't want to drill holes in the walls separating the adjacent walls.

Asked by: Anonymous
Yes. You can move the meter from room to room and monitor the change in the readings.
Answered by: Applicatrions Engineer JK
Date published: 2020-04-03

What is the resolution of HHC280 when measuring under 100 Pa? The datasheet is a bit confusing. Is it 10 Pa or 1Pa?

Asked by: RJag
Thank you for your inquiry, the Resolution is : 0.1 hpa/0.1 mmH2O
Answered by: rkent
Date published: 2022-02-08

What we can do in case of OOT ? Thanks in advance

Asked by: JW1964
If the HHC280 unit is out of tolerance it would need to be returned to us for evaluation. There are no field calibration procedures available.
Answered by: Applications Engineer JK
Date published: 2021-06-14
  • y_2026, m_8, d_3, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.48
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_HHC280, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration